98 research outputs found

    Pseudo-no-Reflow Phenomenon in Carotid Artery Stenting using FilterWire EX: Successful Recovery by Aspiration Thrombectomy

    Get PDF
    Distal protection devices such as FilterWire EX have been widely used in carotid artery stenting, however, the large amount of atherothrombotic debris entrapped in the filter could reduce or stop antegrade flow. We present a case of pseudo-no-reflow phenomenon after postdilatation of the stent in a patient with asymptomatic carotid artery stenosis. After several passes using an Export Aspiration catheter, normal flow in the internal carotid artery was restored. Aspiration thrombectomy can successfully recover pseudo-no-reflow phenomenon

    Newly developed post-operative atrial fibrillation is associated with an increased risk of late recurrence of atrial fibrillation in patients who underwent open heart surgery: Long-term follow up

    Get PDF
    Background: Herein is sought to determine whether the occurrence of post-operative atrial fibrillation (POAF) increases the risk of late recurrence of atrial fibrillation (AF) in patients undergoing open heart surgery (OHS). Methods: This study included 938 patients (56.7 ± 13.1 years old, 550 males) with no history of AF who underwent OHS. All patients were monitored continuously for development of POAF after surgery until the time of hospital discharge and received clinical follow up with serial evaluation of rhythm status. Results: Among the total population, POAF occurred in 207 (22.1%) patients and late AF in 88 (9.4%) patients during the mean follow up period of 78.1 ± 39.1 months. Development of late AF oc¬curred more frequently in patients with POAF than in those without [29.0% (60/207) vs. 3.8% (28/731), p < 0.01]. Higher septal E/e’ ratio (HR 1.04, 95% CI 1.00–1.08, p = 0.04) was an independent predic¬tor of late occurrence of AF and an episode of POAF (HR 27.12, 95% CI 8.46–86.96, p < 0.01) was the most powerful predictor. Conclusions: POAF is significantly associated with an increased risk of late AF recurrence during long-term follow up. Careful concern regarding late recurrence of AF with serial evaluation of rhythm status is required in patients with POAF

    Acute Severe Symptomatic Hyponatremia Following Coronary Angiography

    Get PDF
    Hyponatremia is a relatively common electrolyte disorder. Although severe acute hyponatremia following coronary angiography is rare, potentially lethal neurologic manifestations may result. We describe a patient with severe, symptomatic hyponatremia, an unusual complication of coronary angiography. Lack of familiarity with contrast media-related hyponatremia caused a delay in diagnosis and therapy in our case. The diagnosis of acute hyponatremia should be considered in any patient who develops behavioral or neurologic manifestations following coronary angiography. Prompt diagnosis and treatment is essential to avoid permanent neurologic damage or death

    Coronary Artery Perforation Following Implantation of a Drug-Eluting Stent Rescued by Deployment of a Covered Stent in Symptomatic Myocardial Bridging

    Get PDF
    We successfully rescued a patient whose coronary artery perforated following implantation of a drug-eluting stent (DES), by deploying a stent-graft in symptomatic myocardial bridging. Our case demonstrated that coronary perforation could be handled without difficulty when perforated myocardial bridging is confined to the interventricular groov
    • …
    corecore