112 research outputs found

    A randomised controlled trial evaluating arrhythmia burden, risk of sudden cardiac death and stroke in patients with Fabry disease:The role of implantable loop recorders (RaILRoAD) compared with current standard practice

    Get PDF
    Background: Fabry disease (FD) is a genetic disorder caused by a deficiency in the enzyme alpha-galactosidase A, leading to an accumulation of glycosphingolipids in tissues across the body. Cardiac disease is the leading cause of morbidity and mortality. Advanced disease, characterised by extensive left ventricular hypertrophy, ventricular dysfunction and fibrosis, is known to be associated with an increase in arrhythmia. Data identifying risk factors for arrhythmia are limited, and no Fabry-specific risk stratification tool is available to select those who may benefit from initiation of medical or device therapy (implantable cardiac defibrillators). Current monitoring strategies have a limited diagnostic yield, and implantable loop recorders (ILRs) have the potential to change treatment and clinical outcomes. Aim: The aim of this study is to determine whether ILRs can (1) improve arrhythmia detection in FD and (2) identify risk predictors of arrhythmia. Methods: A prospective, 5-year, open-label, international, multi-centre randomised controlled trial of a minimum of 164 participants with genetically or enzymatically confirmed FD (or both) who have evidence of cardiac disease will be recruited from five centres: Queen Elizabeth Hospital, Birmingham, UK; Salford Royal Hospital, Salford, UK; Royal Free Hospital, London, UK; Addenbrookes Hospital, Cambridge, UK; and Westmead Hospital, Sydney, Australia. Participants will be block-randomised (1:1) to two study arms for cardiac monitoring (i) control arm: standard of care with annual 24 h or 5-day Holter monitor or (ii) treatment arm: continuous cardiac monitoring with ILR implantation plus standard of care. Participants will undergo multiple investigations - blood/urine biomarkers, 12-lead and advanced electrocardiogram (ECG) recording, echocardiography and cardiovascular magnetic resonance (CMR) imaging - at baseline and 6-12 monthly follow-up visits. The primary endpoint is identification of arrhythmia requiring initiation or alteration in therapy. Secondary outcome measures include characterising the risk factors associated with arrhythmia and outcome data in the form of imaging, ECG and blood biomarkers. Discussion: This is the first study evaluating arrhythmia burden and the use of ILR across the spectrum of risk profiles in Fabry cardiomyopathy. This will enable detailed characterisation of arrhythmic risk predictors in FD and ultimately support formulation of Fabry-specific guidance in this high-risk population. Trial registration: ClinicalTrials.gov (NCT03305250). Registered on 9 October 2017

    Differential sensing with arrays of de novo designed peptide assemblies

    Get PDF
    Differential sensing attempts to mimic the mammalian senses of smell and taste to identify analytes and complex mixtures. In place of hundreds of complex, membrane-bound G-protein coupled receptors, differential sensors employ arrays of small molecules. Here we show that arrays of computationally designed de novo peptides provide alternative synthetic receptors for differential sensing. We use self-assembling α-helical barrels (αHBs) with central channels that can be altered predictably to vary their sizes, shapes and chemistries. The channels accommodate environment-sensitive dyes that fluoresce upon binding. Challenging arrays of dye-loaded barrels with analytes causes differential fluorophore displacement. The resulting fluorimetric fingerprints are used to train machine-learning models that relate the patterns to the analytes. We show that this system discriminates between a range of biomolecules, drink, and diagnostically relevant biological samples. As αHBs are robust and chemically diverse, the system has potential to sense many analytes in various settings

    How effective is tetracaine 4% gel, before a venipuncture, in reducing procedural pain in infants: a randomized double-blind placebo controlled trial

    Get PDF
    BACKGROUND: Procedural pain relief is sub-optimal in neonates. Topical tetracaine provides pain relief in children. Evidence of its efficacy and safety in neonates is limited. The objective of this study was to assess the efficacy and safety of topical tetracaine on the pain response of neonates during a venipuncture. METHODS: Medically stable infants greater than or equal to 24 weeks gestation, requiring a venipuncture, were included. Following randomization and double blinding, 1.1 g of tetracaine or placebo was applied to the skin for 30 minutes. Participants received oral sucrose if they met local eligibility criteria. The venipuncture was performed according to a standard protocol. A medium effect size in the pain score (corresponding to about 2 point difference in the PIPP score) was considered clinically significant, leading to a sample size of 142 infants, with 80% statistical power. Local skin reactions and immediate adverse cardiorespiratory events were noted. The primary outcome, PIPP score at 1 minute, was analysed using an independent Student's t-test. RESULTS: One hundred and forty two infants were included, 33 +/- 4 weeks gestation, 2100 +/- 900 grams and 6 +/- 3 days of age. There was almost no difference in PIPP scores at 1 minute between groups (mean difference -0.09; 95% confidence interval [CI]: -1.68 to 1.50; P = . 91). Similarly, there were no differences in PIPP scores during the 2(nd), 3(rd )and 4th minute. Duration of cry did not differ between the groups (median difference, 0; 95% CI, -3 to 0; P = . 84). The majority of infants in both groups received sucrose 24%. Sucrose had a significant effect on the PIPP score, as assessed by an ANOVA model (p = 0.0026). Local skin erythema was observed transiently in 11 infants (7 in the tetracaine and 4 in the placebo group). No serious side effect was observed. CONCLUSION: Tetracaine did not significantly decrease procedural pain in infants undergoing a venipuncture, when used in combination with routine sucrose administration

    How effective is tetracaine 4% gel, before a peripherally inserted central catheter, in reducing procedural pain in infants: a randomized double-blind placebo controlled trial [ISRCTN75884221]

    Get PDF
    BACKGROUND: Procedural pain relief is sub-optimal in infants, especially small and vulnerable ones. Tetracaine gel 4% (Ametop(®), Smith-Nephew) provides pain relief in children and larger infants, but its efficacy in smaller infants and for peripherally inserted central catheters (PICC) remains uncertain. The objective of this trial was to assess the safety and efficacy of tetracaine gel on the pain response of very low birth weight (VLBW) infants during insertion of a PICC. METHODS: Medically stable infants greater than or equal to 24 weeks gestation, requiring a non-urgent PICC, were included. Following randomization and double blinding, 1.1 g of tetracaine or placebo was applied to the skin for 30 minutes. The PICC was inserted according to a standard protocol. Pain was assessed using the Premature Infant Pain Profile (PIPP). A 3-point change in the pain score was considered clinically significant, leading to a sample size of 54 infants, with 90% statistical power. Local skin reactions and immediate adverse cardiorespiratory events were noted. The primary outcome, PIPP score at 1 minute, was analysed using an independent Student's t-test. RESULTS: Fifty-four infants were included, 27 +/- 2 weeks gestation, 916 +/- 292 grams and 6.5 +/- 3.2 days of age. Baseline characteristics were similar between groups. The mean PIPP score in the first minute was 10.88 in the treatment group as compared to 11.74 in the placebo group (difference 0.86, 95% CI -1.86, 3.58). Median duration of crying in non-intubated infants was 181 seconds in the tetracaine group compared to 68 seconds in the placebo group (difference -78, 95% CI -539, 117). Local skin erythema was observed transiently in 4 infants (3 in the treatment and 1 in the placebo group). No serious harms were observed. CONCLUSION: Tetracaine 4% when applied for 30 minutes was not beneficial in decreasing procedural pain associated with a PICC in very small infants

    Development and evaluation of low-volume tests to detect and characterize antibodies to SARS-CoV-2

    Get PDF
    Low-volume antibody assays can be used to track SARS-CoV-2 infection rates in settings where active testing for virus is limited and remote sampling is optimal. We developed 12 ELISAs detecting total or antibody isotypes to SARS-CoV-2 nucleocapsid, spike protein or its receptor binding domain (RBD), 3 anti-RBD isotype specific luciferase immunoprecipitation system (LIPS) assays and a novel Spike-RBD bridging LIPS total-antibody assay. We utilized pre-pandemic (n=984) and confirmed/suspected recent COVID-19 sera taken pre-vaccination rollout in 2020 (n=269). Assays measuring total antibody discriminated best between pre-pandemic and COVID-19 sera and were selected for diagnostic evaluation. In the blind evaluation, two of these assays (Spike Pan ELISA and Spike-RBD Bridging LIPS assay) demonstrated >97% specificity and >92% sensitivity for samples from COVID-19 patients taken >21 days post symptom onset or PCR test. These assays offered better sensitivity for the detection of COVID-19 cases than a commercial assay which requires 100-fold larger serum volumes. This study demonstrates that low-volume in-house antibody assays can provide good diagnostic performance, and highlights the importance of using well-characterized samples and controls for all stages of assay development and evaluation. These cost-effective assays may be particularly useful for seroprevalence studies in low and middle-income countries
    • …
    corecore