109 research outputs found

    Design considerations for the ideal low vision aid: insights from de-brief interviews following a real-world recording study

    Get PDF
    PURPOSE: Low Vision Aids (LVAs) can have a transformative impact on people living with sight loss, yet the everyday requirements for developing such devices remain poorly understood and defined. This study systematically explored LVA requirements through a structured de-brief interview following a real-world self-recording study. The purpose of this work was to define the actual needs of those living with sight loss so that low vision services can better address them in future. METHODS: Thirty-two visually impaired volunteers with varying levels of previous LVA experience participated in a de-brief interview centred around a structured questionnaire. The de-brief followed a one-week real-world study during which participants used recoding spectacles to capture and narrate all situations in which they would use a ‘perfect sight aid’. Content and thematic analyses were used to analyse interviews which had the purpose of contextualising these recordings and exploring requirements around psychological, functional and design factors. CONCLUSIONS: There is a substantial opportunity for new LVAs to address visual needs that traditional devices and coping strategies cannot support. Functional, psychological and design factors require careful consideration for future LVAs to be relevant and widely adopted

    Everyday visual demands of people with low vision: A mixed methods real-life recording study

    Get PDF
    Research has demonstrated that low vison aids (LVAs) can have a positive impact on the functional sight of those living with sight loss. Step changes in technology are now enabling new wearable LVAs with greater potential than those available previously. For these novel devices to receive increased acceptance and therefore adoption by those with sight loss, visual task demands have to be understood more clearly in order to enable better alignment between device design and user requirements. The aim of this study was to quantify these requirements. Thirty-two participants aged 18 to 87 wore a spectacle-mounted video camera to capture and narrate all everyday situations in which they would use a “perfect” sight aid during 1 week. Captured scenes were analyzed through categorization and computational image analysis. Results showed large variation in activities and lifestyles. Participants reported no available sight aid or coping strategy for 57% of the recorded activities. Reading made up 49% of all recorded tasks, the other half comprising non-textual information. Overall, 75% of captured activities were performed ad hoc (duration of 0–5 minutes), 78% occurred indoors, 58% occurred at home, 48% were lit by natural light, 68% included the object of interest within reach, and 69% required a single focus plane only. Around half of captured objects of interest had a size of 2 degrees visual angle (2.08 logarithm of the minimum angle of resolution [logMAR]) or smaller. This study highlights the need for a sight aid that can make both textual and non-textual scenes accessible while offering flexibility to accommodate individual lifestyles

    Bilateral Sutureless Application of Human Dehydrated Amniotic Membrane with a Specialised Bandage Contact Lens for Moderate-to-Severe Dry Eye Disease: A Prospective Study with 1-Month Follow-Up

    Get PDF
    SĂČnia TravĂ©-Huarte, James S Wolffsohn Optometry and Vision Science Research Group, College of Health and Life Sciences, Aston University, Birmingham, UKCorrespondence: SĂČnia TravĂ©-Huarte, School of Optometry, Aston University, Birmingham, UK, Tel +44 1212044400, Email [email protected]: To assess changes in symptoms and ocular surface signs following a bilateral sutureless treatment of dehydrated amniotic membrane (dAM) under a specialised bandage contact lens (sBCL) in patients with moderate-to-severe dry eye disease (DED).Patients and Methods: In this prospective pre-post interventional study, 35 patients diagnosed with moderate-to-severe DED, with an Ocular Surface Disease Index (OSDI) score > 30 on current treatment, were enrolled. Assessments were conducted at baseline (day − 30), after 30 days run-in with no additional treatment (day 0 – control), and 30 days post sBCL+dAM treatment (day 30 – treatment). Intervention involved two successive bilateral 4-5 day sutureless applications of dAM (17mm diameter, with a 6 mm central aperture, OmnigenÂź VIEW) under an 18mm sBCL (OmniLenzÂź). Symptomatology and ocular signs were measured using OSDI, Dry Eye Questionnaire-5 (DEQ-5), Symptom Assessment iN Dry Eye (SANDE), and other ocular surface health indicators including non-invasive breakup time, corneal and conjunctival staining, and lid wiper epitheliopathy length and width (LWE).Results: While symptomatology remained stable during the 30-day no-treatment run-in, 1-month post-dAM treatment, there was a significant reduction in OSDI scores (from 55.8 to 32.3, p< 0.001), DEQ-5 (from 14.6 to 10.0, p< 0.001), SANDE frequency (from 65.2 to 43.6, p< 0.001), and SANDE severity (from 59.8 to 41.1, p< 0.001). Additionally, there was a notable decrease in the width of LWE staining, from grade 2 (50– 75% of the lid wiper) to grade 1 (25– 50% of the lid wiper) (p=0.011).Conclusion: A bilateral 8– 10-day treatment duration with dAM applied with sBCL demonstrated a 31 to 42% improvement in symptomatology and a decrease in ocular surface signs of mechanical stress. This innovative bilateral treatment approach offers a promising treatment modality for patients with refractory moderate-to-severe DED.Keywords: dry eye disease, amniotic membrane, bandage contact len

    Presbyopic LASIK using hybrid bi-aspheric micro-monovision ablation profile for presbyopic corneal treatments.

    Get PDF
    PURPOSE: To evaluate distance and near image quality after hybrid bi-aspheric multifocal central presbyLASIK treatments. DESIGN: Consecutive case series. METHODS: Sixty-four eyes of 32 patients consecutively treated with central presbyLASIK were assessed. The mean age of the patients was 51 ± 3 years with a mean spherical equivalent refraction of -1.08 ± 2.62 diopters (D) and mean astigmatism of 0.52 ± 0.42 D. Monocular corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), and distance corrected near visual acuity (DCNVA) of nondominant eyes; binocular uncorrected distance visual acuity (UDVA); uncorrected intermediate visual acuity (UIVA); distance corrected intermediate visual acuity (DCIVA); and uncorrected near visual acuity (UNVA) were assessed pre- and postoperatively. Subjective quality of vision and near vision was assessed using the 10-item Rasch-scaled Quality of Vision and Near Activity Visual Questionnaire, respectively. RESULTS: At 1 year postoperatively, 93% of patients achieved 20/20 or better binocular UDVA; 90% and 97% of patients had J2 or better UNVA and UIVA, respectively; 7% lost 2 Snellen lines of CDVA; Strehl ratio reduced by ∌-4% ± 14%. Defocus curves revealed a loss of half a Snellen line at best focus, with no change for intermediate vergence (-1.25 D) and a mean gain of 2 lines for near vergence (-3 D). CONCLUSIONS: Presbyopic treatment using a hybrid bi-aspheric micro-monovision ablation profile is safe and efficacious. The postoperative outcomes indicate improvements in binocular vision at far, intermediate, and near distances with improved contrast sensitivity. A 19% retreatment rate should be considered to increase satisfaction levels, besides a 3% reversal rate

    Editorial: International Myopia Institute White Paper Series 2023

    Full text link

    Additional psychometric information and vision-specific questionnaires are available for age-realted macular degeneration

    Get PDF
    Purpose: To present psychometric information and studies dealing with questionnaires for age-related macular degeneration (AMD) and visually impaired patients in addition to the study by Finger et al. "Quality of life in AMD: a review of available vision-specific psychometric tools". We propose that their literature search should not have focused solely on the specific eye disease AMD. Methods: The literature search was partly replicated (PubMed) by using "visual impairment" instead of "macular degeneration" as free text words. Psychometric information was obtained from the additional studies. Preliminary results from a differential item functioning (DIF) analysis used to examine the relationship between item responses on the Vision-related quality of life Core Measure (VCM1) of AMD patients versus patients with other eye conditions are discussed. Results: Eight studies of visually impaired patient populations, including AMD patients, are discussed, with psychometric information from six vision-specific questionnaires. The VCM1 items did not present DIF, which means that the items were equally interpreted by all patients. Conclusions: The results on DIF and the additional studies presented here confirm that a specific eye disorder is of minor importance in the choice of a vision-specific questionnaire or, in this case, a literature search

    TFOS Lifestyle: Impact of nutrition on the ocular surface: TFOS Lifestyle Workshop: Nutrition report

    Full text link
    Nutrients, required by human bodies to perform life-sustaining functions, are obtained from the diet. They are broadly classified into macronutrients (carbohydrates, lipids, and proteins), micronutrients (vitamins and minerals) and water. All nutrients serve as a source of energy, provide structural support to the body and/or regulate the chemical processes of the body. Food and drinks also consist of non-nutrients that may be beneficial (e.g., antioxidants) or harmful (e.g., dyes or preservatives added to processed foods) to the body and the ocular surface. There is also a complex interplay between systemic disorders and an individual's nutritional status. Changes in the gut microbiome may lead to alterations at the ocular surface. Poor nutrition may exacerbate select systemic conditions. Similarly, certain systemic conditions may affect the uptake, processing and distribution of nutrients by the body. These disorders may lead to deficiencies in micro- and macro-nutrients that are important in maintaining ocular surface health. Medications used to treat these conditions may also cause ocular surface changes. The prevalence of nutrition-related chronic diseases is climbing worldwide. This report sought to review the evidence supporting the impact of nutrition on the ocular surface, either directly or as a consequence of the chronic diseases that result. To address a key question, a systematic review investigated the effects of intentional food restriction on ocular surface health; of the 25 included studies, most investigated Ramadan fasting (56%), followed by bariatric surgery (16%), anorexia nervosa (16%), but none were judged to be of high quality, with no randomized-controlled trials

    Effects of standard training in the use of closed-circuit televisions in visually impaired adults: design of a training protocol and a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reading problems are frequently reported by visually impaired persons. A closed-circuit television (CCTV) can be helpful to maintain reading ability, however, it is difficult to learn how to use this device. In the Netherlands, an evidence-based rehabilitation program in the use of CCTVs was lacking. Therefore, a standard training protocol needed to be developed and tested in a randomized controlled trial (RCT) to provide an evidence-based training program in the use of this device.</p> <p>Methods/Design</p> <p>To develop a standard training program, information was collected by studying literature, observing training in the use of CCTVs, discussing the content of the training program with professionals and organizing focus and discussion groups. The effectiveness of the program was evaluated in an RCT, to obtain an evidence-based training program. Dutch patients (n = 122) were randomized into a treatment group: normal instructions from the supplier combined with training in the use of CCTVs, or into a control group: instructions from the supplier only. The effect of the training program was evaluated in terms of: change in reading ability (reading speed and reading comprehension), patients' skills to operate the CCTV, perceived (vision-related) quality of life and tasks performed in daily living.</p> <p>Discussion</p> <p>The development of the CCTV training protocol and the design of the RCT in the present study may serve as an example to obtain an evidence-based training program. The training program was adjusted to the needs and learning abilities of individual patients, however, for scientific reasons it might have been preferable to standardize the protocol further, in order to gain more comparable results.</p> <p>Trial registration</p> <p><url>http://www.trialregister.nl</url>, identifier: NTR1031</p

    Re-evaluating a vision-related quality of life questionnaire with item response theory (IRT) and differential item functioning (DIF) analyses

    Get PDF
    Background: For the Low Vision Quality Of Life questionnaire (LVQOL) it is unknown whether the psychometric properties are satisfactory when an item response theory (IRT) perspective is considered. This study evaluates some essential psychometric properties of the LVQOL questionnaire in an IRT model, and investigates differential item functioning (DIF). Methods: Cross-sectional data were used from an observational study among visually-impaired patients (n = 296). Calibration was performed for every dimension of the LVQOL in the graded response model. Item goodness-of-fit was assessed with the S-X2-test. DIF was assessed on relevant background variables (i.e. age, gender, visual acuity, eye condition, rehabilitation type and administration type) with likelihood-ratio tests for DIF. The magnitude of DIF was interpreted by assessing the largest difference in expected scores between subgroups. Measurement precision was assessed by presenting test information curves; reliability with the index of subject separation. Results: All items of the LVQOL dimensions fitted the model. There was significant DIF on several items. For two items the maximum difference between expected scores exceeded one point, and DIF was found on multiple relevant background variables. Item 1 ‘Vision in general’ from the “Adjustment” dimension and item 24 ‘Using tools’ from the “Reading and fine work” dimension were removed. Test information was highest for the “Reading and fine work” dimension. Indices for subject separation ranged from 0.83 to 0.94. Conclusions: The items of the LVQOL showed satisfactory item fit to the graded response model; however, two items were removed because of DIF. The adapted LVQOL with 21 items is DIF-free and therefore seems highly appropriate for use in heterogeneous populations of visually impaired patients. (aut.ref.
    • 

    corecore