7 research outputs found

    Analytical methods applied to diverse types of Brazilian propolis

    Get PDF
    Propolis is a bee product, composed mainly of plant resins and beeswax, therefore its chemical composition varies due to the geographic and plant origins of these resins, as well as the species of bee. Brazil is an important supplier of propolis on the world market and, although green colored propolis from the southeast is the most known and studied, several other types of propolis from Apis mellifera and native stingless bees (also called cerumen) can be found. Propolis is usually consumed as an extract, so the type of solvent and extractive procedures employed further affect its composition. Methods used for the extraction; analysis the percentage of resins, wax and insoluble material in crude propolis; determination of phenolic, flavonoid, amino acid and heavy metal contents are reviewed herein. Different chromatographic methods applied to the separation, identification and quantification of Brazilian propolis components and their relative strengths are discussed; as well as direct insertion mass spectrometry fingerprinting

    Laser Ablated Albumin Functionalized Spherical Gold Nanoparticles Indicated for Stem Cell Tracking

    No full text
    Cell tracking in cell-based therapy applications helps distinguish cell participation among paracrine effect, neovascularization, and matrix deposition. This preliminary study examined the cellular uptake of gold nanoparticles (AuNPs), observing cytotoxicity and uptake of different sizes and AuNPs concentrations in Adipose-derived stromal cells (ASCs). ASCs were incubated for 24 h with Laser ablated Albumin functionalized spherical AuNPs (LA-AuNPs), with average sizes of 2 nm and 53 nm in diameter, in four concentrations, 127 µM, 84 µM, 42 µM, and 23 µM. Cytotoxicity was examined by Live/Dead assay, and erythrocyte hemolysis, and the effect on the cytoskeleton was investigated by immunocytochemistry for β-actin. The LA-AuNPs were internalized by the ASCs in a size and concentration-dependent manner. Clusters were observed as dispersed small ones in the cytosol, and as a sizeable perinuclear cluster, without significant harmful effects on the cells for up to 2 weeks. The Live/Dead and hemolysis percentage results complemented the observations that the larger 53 nm LA-AuNPs in the highest concentrated solution significantly lowered cell viability. The demonstrated safety, cellular uptake, and labelling persistency with LA-AuNPs, synthesized without the combination of chemical solutions, support their use for cell tracking in tissue engineering applications

    Which factors contribute to false-positive, false-negative, and invalid results in fetal fibronectin testing in women with symptoms of preterm labor?

    No full text
    \u3cp\u3eObjective We assessed the influence of external factors on false-positive, false-negative, and invalid fibronectin results in the prediction of spontaneous delivery within 7 days. Methods We studied symptomatic women between 24 and 34 weeks' gestational age. We performed uni- and multivariable logistic regression to estimate the effect of external factors (vaginal soap, digital examination, transvaginal sonography, sexual intercourse, vaginal bleeding) on the risk of false-positive, false-negative, and invalid results, using spontaneous delivery within 7 days as the outcome. Results Out of 708 women, 237 (33%) had a false-positive result; none of the factors showed a significant association. Vaginal bleeding increased the proportion of positive fetal fibronectin (fFN) results, but was significantly associated with a lower risk of false-positive test results (odds ratio [OR], 0.22; 95% confidence intervals [CI], 0.12-0.39). Ten women (1%) had a false-negative result. None of the investigated factors was significantly associated with a significantly higher risk of false-negative results. Twenty-one tests (3%) were invalid; only vaginal bleeding showed a significant association (OR, 4.5; 95% CI, 1.7-12). Conclusion The effect of external factors on the performance of qualitative fFN testing is limited, with vaginal bleeding as the only factor that reduces its validity.\u3c/p\u3
    corecore