113 research outputs found

    Teaching Teachers About Reading Comprehension

    Get PDF

    Pomegranate: An Eco-Friendly Source for Green Energy Storage Devices

    Get PDF
    With an increasing demand for energy and concerns about the environment, scientists are trying to find a better way to generate green energy and to efficiently store the generated energy. Biowaste could be an attractive source for the preparation of active materials for energy storing devices. In this project, a shell of pomegranate was used for the preparation of high surface area carbon for supercapacitor applications. The dry powder of a pomegranate was chemically activated using various ratios of pomegranate and activating agent to produce carbon with a range of different properties. The surface area of the pomegranate-based carbon was 40 m2/g, which improved to 1459, 1737, and 2189 m2/g upon chemical activation using, 1:1, 1:2, and 1:3 ratios of pomegranate: activating agent, respectively. The energy storage capacity was calculated using galvanostatic charge-discharge measurements, and the highest specific capacitance of 190 F/g at 1 A/g was observed for PG-2 (1:2 ratio of pomegranate: activating agent) activated pomegranate-based carbon. Using the electrode, the symmetric supercapacitor devices were fabricated utilizing various electrolytes (aqueous, organic, and ionic liquid electrolytes). From the Ragone curve, the highest energy and power density of [8.8 Wh kg-1, 3,950 W kg-1], [39 Wh kg-1, 8,943 W kg-1], and [68 Wh kg-1, 11,316 W kg-1] was obtained for aqueous, organic, and ionic liquid electrolytes, respectively. Our research suggests that pomegranate-based carbon could be an attractive material for the fabrication of energy storage devices

    Effectiveness of computer-navigated minimally invasive total hip surgery compared to conventional total hip arthroplasty: design of a randomized controlled trial

    Get PDF
    BACKGROUND: Moderate to severe osteoarthrosis is the most common indication for Total Hip Arthroplasty (THA). Minimally Invasive Total Hip Surgery (MIS) and computer-navigated surgery were introduced several years ago. However, the literature lacks well-designed studies that provide evidence of superiority of computer-navigated MIS over a conventional THA technique. Hence, the purpose of this study is to compare (cost)effectiveness of computer-navigated MIS with a conventional technique for THA. It is our hypothesis that computer-navigated MIS will lead to a quicker recovery during the early postoperative period (3 months), and to an outcome at least as good 6 months postoperatively. We also hypothesize that computer-navigated MIS leads to fewer perioperative complications and better prosthesis positioning. Furthermore, cost advantages of computer-navigated MIS over conventional THA technique are expected. METHODS/DESIGN: A cluster randomized controlled trial will be executed. Patients between the ages of 18 and 75 admitted for primary cementless unilateral THA will be included. Patients will be stratified using the Charnley classification. They will be randomly allocated to have computer-navigated MIS or conventional THA technique. Measurements take place preoperatively, perioperatively, and 6 weeks and 3 and 6 months postoperatively. Degree of limping (gait analysis), self-reported functional status and health-related quality of life (questionnaires) will be assessed preoperatively as well as postoperatively. Perioperative complications will be registered. Radiographic evaluation of prosthesis positioning will take place 6 weeks postoperatively. An evaluation of costs within and outside the healthcare sector will focus on differences in costs between computer-navigated MIS and conventional THA technique. DISCUSSION: Based on studies performed so far, few objective data quantifying the risks and benefits of computer-navigated MIS are available. Therefore, this study has been designed to compare (cost) effectiveness of computer-navigated MIS with a conventional technique for THA. The results of this trial will be presented as soon as they become available

    Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

    Get PDF
    ABSTRACT: BACKGROUND: Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. METHODS: An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. RESULTS: Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. CONCLUSIONS: The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis

    Electromagnetic Field Effect or Simply Stress? Effects of UMTS Exposure on Hippocampal Longterm Plasticity in the Context of Procedure Related Hormone Release

    Get PDF
    Harmful effects of electromagnetic fields (EMF) on cognitive and behavioural features of humans and rodents have been controversially discussed and raised persistent concern about adverse effects of EMF on general brain functions. In the present study we applied radio-frequency (RF) signals of the Universal Mobile Telecommunications System (UMTS) to full brain exposed male Wistar rats in order to elaborate putative influences on stress hormone release (corticosteron; CORT and adrenocorticotropic hormone; ACTH) and on hippocampal derived synaptic long-term plasticity (LTP) and depression (LTD) as electrophysiological hallmarks for memory storage and memory consolidation. Exposure was computer controlled providing blind conditions. Nominal brain-averaged specific absorption rates (SAR) as a measure of applied mass-related dissipated RF power were 0, 2, and 10 W/kg over a period of 120 min. Comparison of cage exposed animals revealed, regardless of EMF exposure, significantly increased CORT and ACTH levels which corresponded with generally decreased field potential slopes and amplitudes in hippocampal LTP and LTD. Animals following SAR exposure of 2 W/kg (averaged over the whole brain of 2.3 g tissue mass) did not differ from the sham-exposed group in LTP and LTD experiments. In contrast, a significant reduction in LTP and LTD was observed at the high power rate of SAR (10 W/kg). The results demonstrate that a rate of 2 W/kg displays no adverse impact on LTP and LTD, while 10 W/kg leads to significant effects on the electrophysiological parameters, which can be clearly distinguished from the stress derived background. Our findings suggest that UMTS exposure with SAR in the range of 2 W/kg is not harmful to critical markers for memory storage and memory consolidation, however, an influence of UMTS at high energy absorption rates (10 W/kg) cannot be excluded

    The Society for Environmental Geochemistry and Health (SEGH): building for the future.

    Get PDF
    The challenges of sustainable development are ever more pressing, and the skills, interests and capabilities of the SEGH member are well-placed to continue to make more meaningful contributions to the environment, society and well-being. We reflect on the historical development of the society, its response to the dynamic international research landscape and the great opportunities ahead. In 2018, SEGH implemented a new board structure after 2–3 years of consultation, with approval of a new constitution and a new strategy across the large number of international board members. While regions were represented by sections in Europe, Asia/Pacific and the USA, the structure required renewal in order to be more representative of the distribution of members and website traffic that had evolved in preceding years. In addition, the society wanted to improve its position for future growth opportunities across rapidly developing regions
    • …
    corecore