22 research outputs found

    3D image analysis of a volcanic deposit

    Get PDF
    During the last decades, X-ray micro CT has become a well established technique for non-destructive testing in a wide variety of research fields. Using a series of X-ray transmission images of the sample at different projection angles, a stack of 2D cross-sections is reconstructed, resulting in a 3D volume representing the X-ray attenuation coefficients of the sample. Since the attenuation coefficient of a material depends on its density and atomic number, this volume provides valuable information about the internal structure and composition of the sample. Although much qualitative information can be derived directly from this 3D volume, researchers usually require more quantitative results to be able to provide a full characterization of the sample under investigation. This type of information needs to be retrieved using specialized image processing software. For most samples, it is imperative that this processing is performed on the 3D volume as a whole, since a sequence of 2D cross sections usually forms an inadequate approximation of the actual structure. The complete processing of a volume consists of three sequential steps. First, the volume is segmented into a set of objects. What these objects represent depends on what property of the sample needs to be analysed. The objects can be for instance concavities, dense inclusions or the matrix of the sample. When dealing with noisy data, it might be necessary to filter the data before applying the segmentation. The second step is the separation of connected objects into a set of smaller objects. This is necessary when objects appear to be connected because of the limited resolution and contrast of the scan. Separation can also be useful when the sample contains a network structure and one wants to study the individual cells of the network. The third and last step consists of the actual analysis of the various objects to derive the different parameters of interest. While some parameters require extensive calculations, others can be obtained easily. The different parameters which can be obtained are related to the size, shape and orientation of the objects. Additionally, the connectivity of a network can be analysed by comparing the set of objects before and after separation. The size of each object can be characterized by its volume, equivalent diameter and the diameter of the maximum inscribed sphere. The surface can be determined by extracting a polygonal mesh from the volume data. Calculation of Feret’s diameter reveals information about the objects elongation. Additionally, the moments of inertia can be calculated to obtain the axes of an equivalent ellipsoid. This data can be used to determine the main axis and therefore the orientation of the object within the sample. Feret’s diameter and the equivalent ellipsoid are representative for the basic shape of the object. Additionally, using a routine that fills concave regions, the convex hull of an object can be retrieved to quantify the convexity. Different ratios can be defined, which compare the surface area with the volume of the object (sphericity) or the volume of the convex hull. These ratios and the convexity characterize the objects roughness and shape. The described parameters are used to characterize volcanic deposits found in the area west of Lac Pavin (lake in Auvergne, France). The samples are taken from the most recent ‘red scoria’ layer, which is believed to be the result of the latest eruption in Western-Europe. There is however, ambiguity on the origin of the layer in terms of age and placement. The aim is to fingerprint this layer in such a way that the various eruptions in the area can be distinguished from one another. Measurements of the vesicle density, volume and connectivity of the investigated deposits provide information about the intensity of the eruption. Additionally, vesicle geometry can be related to the magmatic permeability, which is essential to the dynamics of the eruption

    Latest developments in 3D analysis of geomaterials by Morpho+

    Get PDF
    At the Centre for X-ray Tomography of the Ghent University (Belgium) (www.ugct.ugent.be) besides hardware development for high-resolution X-ray CT scanners, a lot of progress is being made in the field of 3D analysis of the scanned samples. Morpho+ is a flexible 3D analysis software which provides the necessary petrophysical parameters of the scanned samples in 3D. Although Morpho+ was originally designed to provide any kind of 3D parameter, it contains some specific features especially designed for the analysis of geomaterial properties like porosity, partial porosity, pore-size distribution, grain size, grain orientation and surface determination. Additionally, the results of the 3D analysis can be visualized which enables to understand and interpret the analysis results in a straightforward way. The complementarities between high-quality X-ray CT images and flexible 3D software are opening up new gateways in the study of geomaterials

    An analysis of the mobility hub concept in the Netherlands:Historical lessons for its implementation

    Get PDF
    The mobility hub concept has become increasingly popular within international research and policies, including in The Netherlands. However, judging by the (still) limited share of multimodality in the Netherlands, similar historical concepts seemed insufficient to prompting a fundamental shift from individual car use to multimodal transport. To enable planners to be better positioned to implement the mobility hub concept, we compared its value with that of related concepts that were previously implemented. Specifically, we examined historical Dutch policy documents and conducted expert and frontrunner interviews to evaluate the mobility hub as a policy concept. We first traced the evolution of the mobility hub, focusing on node and place-based concepts that have been implemented since the second half of the 20th century. We found that related concepts, such as Park and Ride (P + R) or transit-oriented development (TOD), have typically focused on improving transfers between collective and feeder transport, while interactions with land use have gained increased attention. We derived policy lessons from the implementation of these historical policy concepts. Our findings suggest that strategically chosen locations, integrated mobility systems, flanking policies, multi-level policy coherence and public–private cooperation are important considerations when implementing mobility hubs. Moreover, shared mobility, mobility as a service, vehicle electrification, and demand-responsive transit could advance the implementation of TOD, P + R, neighbourhood and rural hubs. In conclusion, the design of different types of mobility hubs should ideally be based on underlying policy objectives and adapted according to context

    Latest developments in 3D analysis of geomaterials by Morpho+

    Get PDF
    At the Centre for X-ray Tomography of the Ghent University (UGCT), a flexible software program has been developed (Morpho+) for 3D analysis of CT data. A lot of adjustments have been made to implement features in Morpho+ which are useful for the analysis of geomaterials. It is possible to calculate the porosity, or density, of the total sample, as well as partial porosity in a longitudinal or radial direction. In order to examine the connectivity of the pore network the Euler number can be determined and the size and position of the bottlenecks can be calculated. There are several parameters to determine the size and shape of pores or grains such as: the surface, the diameter of the maximum inscribed sphere, the diameter of the minimum circumscribed sphere and the equivalent diameter. Comparison of these parameters allows to determine the sphericity of the grains or pores. Morpho+ produces a quantitative output, but it is also possible to visualize the different steps of the analysis, which enables easy interpretation of the results. For example 3D volumes of the scanned grains can be color labeled based on their size, or the volume can be saved as an STL-file. Additionally it is possible to create a skeleton of the pore network

    Potential of X-ray computed tomography for 3D anatomical analysis and microdensitometrical assessment in wood research with focus on wood modification

    Get PDF
    Studying structure and chemistry of wood and wood-based materials is the backbone of all wood research and many techniques are at hand to do so. A very valuable modality is X-ray computed tomography (CT), able to non-destructively probe the three-dimensional (3D) structure and composition. In this paper, we elaborate on the use of Nanowood, a flexible multi-resolution X-ray CT set-up developed at UGCT, the Ghent University Centre for X-ray Tomography. The technique has been used successfully in many different fields of wood science. It is illustrated how 3D structural and microdensitometrical data can be obtained using different scan set-ups and protocols. Its potential for the analysis of modified wood is exemplified, e.g. for the assessment of wood treated with hydrophobing agents, localisation of modification agents, pathway analysis related to functional tissues, dimensional changes due to thermal treatment, etc. Furthermore, monitoring of transient processes is a promising field of activity too

    A robust human norovirus replication model in zebrafish larvae.

    Get PDF
    Human noroviruses (HuNoVs) are the most common cause of foodborne illness, with a societal cost of $60 billion and 219,000 deaths/year. The lack of robust small animal models has significantly hindered the understanding of norovirus biology and the development of effective therapeutics. Here we report that HuNoV GI and GII replicate to high titers in zebrafish (Danio rerio) larvae; replication peaks at day 2 post infection and is detectable for at least 6 days. The virus (HuNoV GII.4) could be passaged from larva to larva two consecutive times. HuNoV is detected in cells of the hematopoietic lineage and the intestine, supporting the notion of a dual tropism. Antiviral treatment reduces HuNoV replication by >2 log10, showing that this model is suited for antiviral studies. Zebrafish larvae constitute a simple and robust replication model that will largely facilitate studies of HuNoV biology and the development of antiviral strategies

    Verkenning van het concept mobiliteitshub

    No full text
    corecore