510 research outputs found

    3D reflection seismic investigation for mine planning and exploration in the Kevitsa Ni-Cu-PGE deposit, Northern Finland

    Get PDF
    A 3D reflection seismic survey was conducted over an area of about 9 km2 at the Kevitsa Ni-Cu-PGE (platinum group elements) deposit, Northern Finland. The principal objective of the survey was to image major fault and fracture zones at depth. Understanding the geometry of these zones is important for designing a steep open-pit for mining. Initial processing results suggest that the 3D seismic survey has been successful in imaging both gently dipping and steeply dipping reflections as shallow as 50 ms (or about 150 m), many of which correlate with fault systems and lithological contacts observed at the surface. Several new target areas can be identified in the seismic data that require further investigations for their mineralization potential

    Interventional Cardiology in Europe 1993

    Get PDF
    An annual survey on cardiac interventions in Europe is performed by the working group on Coronary Circulation of the European Society of Cardiology with the help of the national societies of cardiology. A questionnaire about cardiac interventions in 1993 was mailed to a representative of the national societies of 35 members of the European Society of Cardiology. The data collection of coronary interventions was delayed by slow backreporting and from 10 of the 35 national members data were missing or grossly incomplete. They were excluded from the analysis. Coronary anglography A total of 756 822 coronary angiograms were reported resulting in an incidence of 1146 ± 1024 per 106 inhabitants, ranging from 24 (Romania) to 3499 (Germany). This represents an increase of 12% compared to 1992. Germany (279 882 cases), France (157 237), the United Kingdom (77 000), Italy (44 934) and Spain (37 591) registered 79% of all the coronary angiograms performed. Percutaneous transluminal coronary angioptasty A total of 183 728 percutaneous transluminal coronary angioplasty cases were reported in 1993, 24% more than in 1992. On average, they accounted for 18 ± 7% (range 8 (Romania) to 35% (Sweden)) of the coronary angiograms. Most of these percutaneous transluminal coronary angioplasties (82%) were confined to a single vessel. In 13% only, percutaneous transluminal coronary angioplasty took place immediately after the diagnostic study. Adjusted per capita, Germany ranks first with 873 percutaneous transluminal coronary angioplasties per 106 inhabitants, followed by France (737), Holland (725), Belgium (713), and Switzerland (665). The European mean of percutaneous transluminal coronary angioplasties per 106 inhabitants was 270 ± 279, representing an increase of 14% compared with 1992. A major in-hospital complication was reported in 3.8% of the patients undergoing percutaneous transluminal coronary angioplasty: 0.6% hospital deaths, 1.5% emergency coronary artery bypass graftings, and 1.7% myocardial infarctions. New devices In 1993 stents were implanted in 6444 patients (3.5% of all percutaneous transluminal coronary angioplasty patients), equally distributed between bail-out situations (53%) and elective procedures. The 14 stent implanting countries showed a mean increase in the incidence of coronary stenting of 53% compared with 1992. Other interventional devices were applied in 7045 cases, i.e. 3.8% of all percutaneous transluminal coronary angioplasty cases. Coronary ultrasound (2194 cases) and coronary angioscopy (380 cases) were performed infrequently. Non-coronary interventions Valvuloplasties were the most frequently performed non-coronary interventions. Six European countries performed more than 300 valvuloplasties each in 1993. Most of them were mitral valvuloplasties in southern countries. Conclusions Although partial backreporting might bias conclusions, several findings of this survey are noteworthy for the participating countries: The number of percutaneous transluminal coronary angioplasties is universally increasing. There is an extremely wide range of coronary angiography and percutaneous transluminal coronary angioplasties performed per population. The most common additional procedure is a stent implantation while other new devices are only rarely applied. Mitral valvuloplasty is the most frequently performed non-coronary intervention. (Eur Heart J 1996; 17: 1318-1328

    Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial.

    Get PDF
    Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. NCT01960504

    Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization

    Get PDF
    Aims The purpose of the Euro Heart Survey Programme of the European Society of Cardiology is to evaluate to which extent clinical practice endorses existing guidelines as well as to identify differences in population profiles, patient management, and outcome across Europe. The current survey focuses on the invasive diagnosis and treatment of patients with established coronary artery disease (CAD). Methods and results Between November 2001 and March 2002, 7769 consecutive patients undergoing invasive evaluation at 130 hospitals (31 countries) were screened for the presence of one or more coronary stenosis >50% in diameter. Patient demographics and comorbidity, clinical presentation, invasive parameters, treatment options, and procedural techniques were prospectively entered in an electronic database (550 variables+29 per diseased coronary segment). Major adverse cardiac events (MACE) were evaluated at 30 days and 1 year. Out of 5619 patients with angiographically proven coronary stenosis (72% of screened population), 53% presented with stable angina while ST elevation myocardial infarction (STEMI) was the indication for coronary angiography in 16% and non-ST segment elevation myocardial infarction or unstable angina in 30%. Only medical therapy was continued in 21%, whereas mechanical revascularization was performed in the remainder [percutaneous coronary intervention (PCI) in 58% and coronary artery bypass grafting (CABG) in 21%]. Patients referred for PCI were younger, were more active, had a lower risk profile, and had less comorbid conditions. CABG was performed mostly in patients with left main lesions (21%), two- (25%), or three-vessel disease (67%) with 4.1 diseased segments, on average. Single-vessel PCI was performed in 82% of patients with either single- (45%), two- (33%), or three-vessel disease (21%). Stents were used in 75% of attempted lesions, with a large variation between sites. Direct PCI for STEMI was performed in 410 cases, representing 7% of the entire workload in the participating catheterization laboratories. Time delay was within 90 min in 76% of direct PCI cases. In keeping with the recommendations of practice guidelines, the survey identified under-use of adjunctive medication (GP IIb/IIIa receptor blockers, statins, and angiotensin-converting enzyme-inhibitors). Mortality rates at 30 days and 1 year were low in all subgroups. MACE primarily consisted of repeat PCI (12%). Conclusion The current Euro Heart Survey on coronary revascularization was performed in the era of bare metal stenting and provides a global European picture of the invasive approach to patients with CAD. These data will serve as a benchmark for the future evaluation of the impact of drug-eluting stents on the practice of interventional cardiology and bypass surger

    Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)

    Get PDF
    BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD 2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD <-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P<0.001) and postprocedural MLD (P= 0.008). CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group

    Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty.

    Get PDF
    BACKGROUND: Beta radiation is effective in reducing vascular neointimal proliferation in animals after injury caused by balloon angioplasty. However, the lowest dose that can prevent restenosis after coronary angioplasty has yet to be determined. METHODS: After successful balloon angioplasty of a previously untreated coronary stenosis, 181 patients were randomly assigned to receive 9, 12, 15, or 18 Gy of radiation delivered by a centered yttrium-90 source. Adjunctive stenting was required in 28 percent of the patients. The primary end point was the minimal luminal diameter six months after treatment, as a function of the delivered dose of radiation. RESULTS: At the time of follow-up coronary angiography, the mean minimal luminal diameter was 1.67 mm in the 9-Gy group, 1.76 mm in the 12-Gy group, 1.83 mm in the 15-Gy group, and 1.97 mm in the 18-Gy group (P=0.06 for the comparison of 9 Gy with 18 Gy), resulting in restenosis rates of 29 percent, 21 percent, 16 percent, and 15 percent, respectively (P=0.14 for the comparison of 9 Gy with 18 Gy). At that time, 86 percent of the patients had had no serious cardiac events. In 130 patients treated with balloon angioplasty alone, restenosis rates were 28 percent, 17 percent, 16 percent, and 4 percent, respectively (P=0.02 for the comparison of 9 Gy with 18 Gy). Among these patients, there was a dose-dependent enlargement of the lumen in 28 percent, 50 percent, 45 percent, and 74 percent of patients, respectively (P<0.001 for the comparison of 9 Gy with 18 Gy). The rate of repeated revascularization was 18 percent with 9 Gy and 6 percent with 18 Gy (P=0.26). CONCLUSIONS: Intracoronary beta radiation therapy produces a significant dose-dependent decrease in the rate of restenosis after angioplasty. An 18-Gy dose not only prevents the renarrowing of the lumen typically observed after successful balloon angioplasty, but actually induces luminal enlargement

    Rationale and design of a randomized clinical trial comparing safety and efficacy of myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: The LANDMARK trial

    Get PDF
    BACKGROUND: The recent approval of transcatheter aortic valve replacement (TAVR) in patients with low operative risk has paved the way for the introduction of novel and potentially improved technologies. The safety and efficacy of these novel technologies should be investigated in randomized control trials against the contemporary TAVR devices. The objective of the LANDMARK trial is to compare the balloon-expandable Myval transcatheter heart valve (THV) series with contemporary THV (SAPIEN THV and Evolut THV series) series in patients with severe symptomatic native aortic stenosis. METHODS/DESIGN: The LANDMARK trial (ClinicalTrials.govNCT04275726, EudraCT number 2020-000,137-40) is a prospective, randomized, multinational, multicenter, open-label, and noninferiority trial of approximately 768 patients treated with TAVR via the transfemoral approach. Patients will be allocated in a 1:1 randomization to Myval THV series (n = 384) or to contemporary THV (n = 384) (either of SAPIEN THV or Evolut THV series). The primary combined safety and efficacy endpoint is a composite of all-cause mortality, all stroke (disabling and nondisabling), bleeding (life-threatening or disabling), acute kidney injury (stage 2 or 3), major vascular complications, prosthetic valve regurgitation (moderate or severe), and conduction system disturbances (requiring new permanent pacemaker implantation), according to the Valve Academic Research Consortium-2 criteria at 30-day follow-up. All patients will have follow-up to 10 years following TAVR. SUMMARY: The LANDMARK trial is the first randomized head-to-head trial comparing Myval THV series to commercially available THVs in patients indicated for TAVR. We review prior data on head-to-head comparisons of TAVR devices and describe the rationale and design of the LANDMARK trial

    Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    Get PDF
    BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition
    corecore