49 research outputs found

    An autoethnographic inquiry into my practice and experiences as a teacher trainer and beginning principal at two international schools in Sri Lanka

    Get PDF
    This thesis uses autoethography to explore the process of leading a teacher training programme in an international school in Sri Lanka, as well as the experience of becoming a Principal of another international school. It comprises two narrative accounts: the first of 20,000 words, describes a year spent in one of the most prestigious international schools in Colombo, and the second of 5,000 words, describes my first three months as Principal of a school in another, smaller town. These two narratives describe events soon after they happened. In the case of the first narrative, I use reflective techniques and the passage of time to look back on the events and my reactions to them from a different perspective. Using qualitative techniques of open and selective coding, the narratives as well as interviews with 15 teachers from the first school were analysed. This revealed the importance of school culture and of respecting the local culture, as well as the need for international schools to maintain contact with the local community. In terms of school leadership the thesis highlights the role of the school principal as the architect and nurturer of school culture, and highlights the role autoethnography can play in developing one’s own leadership skills. I attempt to evaluate my own autoethnographic accounts in terms of criteria presented by Bochner and Richardson (2000), and demonstrate my own process of personal and professional development. The thesis presents a case for the application of autoethnography to the fields of teacher development and school leadership

    BIS monitoring versus clinical assessment for sedation in mechanically ventilated adults in the intensive care unit and its impact on clinical outcomes and resource utilization.

    Get PDF
    BACKGROUND: Patients admitted to intensive care and on mechanical ventilation, are administered sedative and analgesic drugs to improve both their comfort and interaction with the ventilator. Optimizing sedation practice may reduce mortality, improve patient comfort and reduce cost. Current practice is to use scales or scores to assess depth of sedation based on clinical criteria such as consciousness, understanding and response to commands. However these are perceived as subjective assessment tools. Bispectral index (BIS) monitors, which are based on the processing of electroencephalographic signals, may overcome the restraints of the sedation scales and provide a more reliable and consistent guidance for the titration of sedation depth.The benefits of BIS monitoring of patients under general anaesthesia for surgical procedures have already been confirmed by another Cochrane review. By undertaking a well-conducted systematic review our aim was to find out if BIS monitoring improves outcomes in mechanically ventilated adult intensive care unit (ICU) patients. OBJECTIVES: To assess the effects of BIS monitoring compared with clinical sedation assessment on ICU length of stay (LOS), duration of mechanical ventilation, any cause mortality, risk of ventilator-associated pneumonia (VAP), risk of adverse events (e.g. self-extubation, unplanned disconnection of indwelling catheters), hospital LOS, amount of sedative agents used, cost, longer-term functional outcomes and quality of life as reported by authors for mechanically ventilated adults in the ICU. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, CINAHL, ProQuest, OpenGrey and SciSearch up to May 2017 and checked references citation searching and contacted study authors to identify additional studies. We searched trial registries, which included clinicaltrials.gov and controlled-trials.com. SELECTION CRITERIA: We included all randomized controlled trials comparing BIS versus clinical assessment (CA) for the management of sedation in mechanically ventilated critically ill adults. DATA COLLECTION AND ANALYSIS: We used Cochrane's standard methodological procedures. We undertook analysis using Revman 5.3 software. MAIN RESULTS: We identified 4245 possible studies from the initial search. Of those studies, four studies (256 participants) met the inclusion criteria. One more study is awaiting classification. Studies were, conducted in single-centre surgical and mixed medical-surgical ICUs. BIS monitor was used to assess the level of sedation in the intervention arm in all the studies. In the control arm, the sedation assessment tools for CA included the Sedation-Agitation Scale (SAS), Ramsay Sedation Scale (RSS) or subjective CA utilizing traditional clinical signs (heart rate, blood pressure, conscious level and pupillary size). Only one study was classified as low risk of bias, the other three studies were classified as high risk.There was no evidence of a difference in one study (N = 50) that measured ICU LOS (Median (Interquartile Range IQR) 8 (4 to 14) in the CA group; 12 (6 to 18) in the BIS group; low-quality evidence).There was little or no effect on the duration of mechanical ventilation (MD -0.02 days (95% CI -0.13 to 0.09; 2 studies; N = 155; I2 = 0%; low-quality evidence)). Adverse events were reported in one study (N = 105) and the effects on restlessness after suction, endotracheal tube resistance, pain tolerance during sedation or delirium after extubation were uncertain due to very low-quality evidence. Clinically relevant adverse events such as self-extubation were not reported in any study. Three studies reported the amount of sedative agents used. We could not measure combined difference in the amount of sedative agents used because of different sedation protocols and sedative agents used in the studies. GRADE quality of evidence was very low. No study reported other secondary outcomes of interest for the review. AUTHORS' CONCLUSIONS: We found insufficient evidence about the effects of BIS monitoring for sedation in critically ill mechanically ventilated adults on clinical outcomes or resource utilization. The findings are uncertain due to the low- and very low-quality evidence derived from a limited number of studies

    Comparison of the immunogenicity of five COVID-19 vaccines in Sri Lanka

    Get PDF
    To determine the antibody responses elicited by different vaccines against SARS-CoV-2, we compared antibody responses in individuals 3 months post-vaccination in those who had received different vaccines in Sri Lanka. Abs to the receptor binding domain (RBD) of the ancestral (wild type) virus (WT) as well as to variants of concern (VoCs), and ACE2 blocking Abs, were assessed in individuals vaccinated with Moderna (n = 225), Sputnik V (n = 128) or Sputnik light (n = 184) and the results were compared with previously reported data on Sinopharm and AZD1222 vaccinees. A total of 99.5% of Moderna, >94% of AZD1222 or Sputnik V and >70% of Sputnik light, >60% of Sinopharm vaccine recipients, had a positive response to ACE2 blocking antibodies. The ACE2 blocking antibody levels were highest to lowest was Moderna > Sputnik V/AZD1222 (had equal levels) > Sputnik light > Sinopharm. All Moderna recipients had antibodies to the RBD of WT, alpha and beta, while positivity rates for delta variant was 80%. The positivity rates for Sputnik V vaccinees for the WT and VoCs were higher than for AZD1222 vaccinees while those who received Sinopharm had the lowest positivity rates (<16.7%). The total antibodies to the RBD were highest for the Sputnik V and AZD1222 vaccinees. The Moderna vaccine elicited the highest ACE2 blocking antibody levels followed by Sputnik V/AZD1222, while those who received Sinopharm had the lowest levels. These findings highlight the need for further studies to understand the effects on clinical outcomes

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    An autoethnographic exploration of my professional experiences as teacher trainer and principal at two international schools in Sri Lanka

    Get PDF
    My research represents an application of the method of autoethnography to the field of teacher education. According to one definition, autoethnography is ‘an autobiographical genre of writing and research that displays multiple layers of consciousness connecting the personal to the cultural’ (Ellis & Bochner 2000: 739). It is associated with the growing acceptance of the use of the self in research which is characteristic of the postmodern era (Muncey 2010: xii). One of its advantages is that it allows voices that are normally hidden to be heard, including those which are deviant in some way or differ from the official explanations given for a phenomenon (ibid.: 110). Any situation that involves human beings is complex, and the opportunities offered by autoethnography allow the researcher to engage productively with this complexity

    Nipple aspirate fluid and its use for the early detection of breast cancer

    Get PDF
    Nipple aspirate fluid is the physiological biofluid lining ductal epithelial cells. Historically, cytology of nipple fluid has been the gold standard diagnostic method for assessment of ductal fluid in patients with symptomatic nipple discharge. The role of biomarker discovery in nipple aspirate fluid for assessment of asymptomatic and high-risk patients is highly attractive but evaluation to date is limited by poor diagnostic accuracy. However, the emergence of new technologies capable of identifying metabolites that have been previously thought unidentifiable within such small volumes of fluid, has enabled testing of nipple biofluid to be re-examined. This review evaluates the use of new technologies to evaluate the components of nipple fluid and their potential to serve as biomarkers in screening
    corecore