96 research outputs found
Nanoparticle detection in an open-access silicon microcavity
We report on the detection of free nanoparticles in a micromachined,
open-access Fabry-P\'erot microcavity. With a mirror separation of m,
a radius of curvature of mm, and a beam waist of m, the mode
volume of our symmetric infrared cavity is smaller than pL. The small
beam waist, together with a finesse exceeding 34,000, enables the detection of
nano-scale dielectric particles in high vacuum. This device allows monitoring
of the motion of individual nm radius silica nanospheres in real time.
We observe strong coupling between the particles and the cavity field, a
precondition for optomechanical control. We discuss the prospects for optical
cooling and detection of dielectric particles smaller than nm in radius
and amu in mass.Comment: 4 pages, 3 figure
Feasibility and cost description of highly intensive rehabilitation involving new technologies in patients with post-acute stroke-a trial of the Swiss RehabTech Initiative
BACKGROUND
There is a need to provide highly repetitive and intensive therapy programs for patients after stroke to improve sensorimotor impairment. The employment of technology-assisted training may facilitate access to individualized rehabilitation of high intensity. The purpose of this study was to evaluate the safety and acceptance of a high-intensity technology-assisted training for patients after stroke in the subacute or chronic phase and to establish its feasibility for a subsequent randomized controlled trial.
METHODS
A longitudinal, multi-center, single-group study was conducted in four rehabilitation clinics. Patients participated in a high-intensity 4-week technology-assisted trainings consisting of 3 to 5 training days per week and at least 5 training sessions per day with a duration of 45 min each. Feasibility was evaluated by examining recruitment, intervention-related outcomes (adherence, subjectively perceived effort and effectiveness, adverse events), patient-related outcomes, and efficiency gains. Secondary outcomes focused on all three domains of the International Classification of Functioning Disability and Health. Data were analyzed and presented in a descriptive manner.
RESULTS
In total, 14 patients after stroke were included. Participants exercised between 12 and 21 days and received between 28 and 82 (mean 46 ± 15) technology-assisted trainings during the study period, which corresponded to 2 to 7 daily interventions. Treatment was safe. No serious adverse events were reported. Minor adverse events were related to tiredness and exertion. From baseline to the end of the intervention, patients improved in several functional performance assessments of the upper and lower extremities. The efficiency gains of the trainings amounted to 10% to 58%, in particular for training of the whole body and for walking training in severely impaired patients.
CONCLUSIONS
Highly intensive technology-assisted training appears to be feasible for in- and outpatients in the subacute or chronic phase after stroke. Further clinical trials are warranted in order to define the most comprehensive approach to highly intensive technology-assisted training and to investigate its efficacy in patients with neurological disorders.
TRIAL REGISTRATION
ClinicalTrials.gov Identifier: NCT03641651 at August 31st 2018
Coulomb plasmas in outer envelopes of neutron stars
Outer envelopes of neutron stars consist mostly of fully ionized, strongly
coupled Coulomb plasmas characterized by typical densities about 10^4-10^{11}
g/cc and temperatures about 10^4-10^9 K. Many neutron stars possess magnetic
fields about 10^{11}-10^{14} G. Here we briefly review recent theoretical
advances which allow one to calculate thermodynamic functions and electron
transport coefficients for such plasmas with an accuracy required for
theoretical interpretation of observations.Comment: 4 pages, 2 figures, latex2e using cpp2e.cls (included). Proc. PNP-10
Workshop, Greifswald, Germany, 4-9 Sept. 2000. Accepted for publication in
Contrib. Plasma Phys. 41 (2001) no. 2-
Hydration Forces Dominate Surface Charge Dependent Lipid Bilayer Interactions under Physiological Conditions
Lipid bilayer interactions are essential to a vast range of biological functions, such as intracellular transport mechanisms. Surface charging mediated by concentration dependent ion adsorption and desorption on lipid headgroups alters electric double layers as well as van der Waals and steric hydration forces of interacting bilayers. Here, we directly measure bilayer interactions during charge modulation in a symmetrically polarized electrochemical three-mirror interferometer surface forces apparatus. We quantify polarization and concentration dependent hydration and electric double layer forces due to cation adsorption/desorption. Our results demonstrate that exponential hydration layer interactions effectively describe surface potential dependent surface forces due to cation adsorption at high salt concentrations. Hence, electric double layers of lipid bilayers are exclusively dominated by inner Helmholtz charge regulation under physiological conditions. These results are important for rationalizing bilayer behavior under physiological conditions, where charge and concentration modulation may act as biological triggers for function and signaling
Third-generation continuous-flow left ventricular assist devices: a comparative outcome analysis by device type.
AIMS
Continuous-flow left ventricular assist devices (CF-LVADs) have become a standard of care in end-stage heart failure. Limited data exist comparing outcomes of HeartMate3 (HM3) and HeartWare HVAD (HW). We aimed to compare midterm outcomes of these devices.
METHODS AND RESULTS
Investigator-initiated retrospective-observational comparative analysis of all patients who underwent primary LVAD implantation of either HM3 or HW at our centre between January 2010 and December 2020. Data were derived from a prospective registry. Primary endpoints were all-cause mortality and heart transplantation. Secondary endpoints included device-related major adverse cardiac and cerebrovascular events, which included major bleeding, major neurological dysfunction (defined as persisting neurological impairment for ≥24 h), device-related major infection (excluding driveline infections), major device malfunctions leading to re-intervention or partial device exchange (pump failure, outflow-graft twist or failure, controller failure, battery failure, patient cable failure, but excluding pump thrombosis), and pump thrombosis. Further secondary endpoints included right heart failure, gastrointestinal bleeding, driveline infections, and surgical re-interventions. The secondary outcomes were analysed not only for the first event but also for recurrent events. The analysis included competing risks analysis and recurrent event regression analysis, with adjustment for confounders age, gender, body mass index (BMI), and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level. Out of 106 primary CF-LVAD implantations, 36 (34%) received HM3 and 70 (66%) received HW. Median follow-up was 1.48 years [interquartile range 0.67, 2.41]. HM3 was more often implanted in men (91.7% vs. 72.9%, P = 0.024); patients were older (median 61 years [54, 66.5] vs. 52.5 years [43, 60], P < 0.001), had a higher BMI (median 26.7 kg/m2 [23.4, 29.0] vs. 24.3 kg/m2 [20.7, 27.4], P = 0.013), had more comorbidities, and were more likely targeted for destination therapy (36.1% vs. 14.3%, P = 0.010). Death occurred in 33.3% of HM3 patients, compared with 22.9% of HW patients, P = 0.247 (probability of survival at 4 years, 54.7% vs. 74.1%, P = 0.296). After adjustment for confounders, we observed a significant six-fold risk increase in device malfunctions for HW [hazard ratio (HR) 6.49, 95% confidence interval (CI) [1.89, 22.32], P = 0.003], but no significant differences in pump thrombosis (P = 0.173) or overall survival (P = 0.801).
CONCLUSIONS
Comparing midterm outcomes between HM3 and HW for LVAD support from a prospective registry, HW patients had a significantly higher risk of device malfunctions. No significant differences were evident between devices in overall survival and in respect to most outcomes
Feasibility and cost description of highly intensive rehabilitation involving new technologies in patients with post-acute stroke : a trial of the Swiss RehabTech Initiative
Background: There is a need to provide highly repetitive and intensive therapy programs for patients after stroke to improve sensorimotor impairment. The employment of technology-assisted training may facilitate access to individualized rehabilitation of high intensity. The purpose of this study was to evaluate the safety and acceptance of a high-intensity technology-assisted training for patients after stroke in the subacute or chronic phase and to establish its feasibility for a subsequent randomized controlled trial.
Methods: A longitudinal, multi-center, single-group study was conducted in four rehabilitation clinics. Patients participated in a high-intensity 4-week technology-assisted trainings consisting of 3 to 5 training days per week and at least 5 training sessions per day with a duration of 45min each. Feasibility was evaluated by examining recruitment, intervention-related outcomes (adherence, subjectively perceived efort and efectiveness, adverse events), patient related outcomes, and efciency gains. Secondary outcomes focused on all three domains of the International Classifcation of Functioning Disability and Health. Data were analyzed and presented in a descriptive manner.
Results: In total, 14 patients after stroke were included. Participants exercised between 12 and 21days and received between 28 and 82 (mean 46±15) technology-assisted trainings during the study period, which corresponded to 2 to 7 daily interventions. Treatment was safe. No serious adverse events were reported. Minor adverse events were related to tiredness and exertion. From baseline to the end of the intervention, patients improved in several functional performance assessments of the upper and lower extremities. The efciency gains of the trainings amounted to 10% to 58%, in particular for training of the whole body and for walking training in severely impaired patients.
Conclusions: Highly intensive technology-assisted training appears to be feasible for in- and outpatients in the subacute or chronic phase after stroke. Further clinical trials are warranted in order to define the most comprehensive approach to highly intensive technology-assisted training and to investigate its efficacy in patients with neurological disorders
Protective immune trajectories in early viral containment of non-pneumonic SARS-CoV-2 infection
The antiviral immune response to SARS-CoV-2 infection can limit viral spread and prevent development of pneumonic COVID-19. However, the protective immunological response associated with successful viral containment in the upper airways remains unclear. Here, we combine a multi-omics approach with longitudinal sampling to reveal temporally resolved protective immune signatures in non-pneumonic and ambulatory SARS-CoV-2 infected patients and associate specific immune trajectories with upper airway viral containment. We see a distinct systemic rather than local immune state associated with viral containment, characterized by interferon stimulated gene (ISG) upregulation across circulating immune cell subsets in non-pneumonic SARS-CoV2 infection. We report reduced cytotoxic potential of Natural Killer (NK) and T cells, and an immune-modulatory monocyte phenotype associated with protective immunity in COVID-19. Together, we show protective immune trajectories in SARS-CoV2 infection, which have important implications for patient prognosis and the development of immunomodulatory therapies
- …