23 research outputs found

    Breath-hold MR cholangiopancreatography with three-dimensional, segmented, echo-planar imaging and volume rendering

    Get PDF
    End-expiration, 21-second breath-hold, three-dimensional magnetic resonance (MR) cholangiopancreatography (MRCP) was developed with segmented echo-planar imaging. In 15 healthy subjects and 14 randomly selected patients undergoing liver studies, three-dimensional MRCP images were obtained and volume rendered. In 15 (100%) healthy subjects and 13 (93%) patients, clear depiction of biliary, hepatic, and pancreatic ducts (with lumen diameter of at least 2 mm) was possible with good signal-to-noise ratio

    Labelling of mammalian cells for visualisation by MRI

    Get PDF
    Through labelling of cells with magnetic contrast agents it is possible to follow the fate of transplanted cells in vivo with magnetic resonance imaging (MRI) as has been demonstrated in animal studies as well as in a clinical setting. A large variety of labelling strategies are available that allow for prolonged and sensitive detection of the labelled cells with MRI. The various protocols each harbour specific advantages and disadvantages. In choosing a particular labelling strategy it is also important to ascertain that the labelling procedure does not negatively influence cell functionality, for which a large variety of assays are available. In order to overcome the challenges still faced in fully exploiting the benefits of in vivo cell tracking by MRI a good understanding and standardisation of the procedures and assays used will be crucial

    Magnetic resonance imaging of the larynx in the pediatric population: A systematic review

    Get PDF
    Abstract Background: Magnetic Resonance Imaging (MRI) techniques to image the larynx have evolved rapidly into a promising and safe imaging modality, without need for sedation or ionizing radiation. MRI is therefore of great interest to image pediatric laryngeal diseases. Our aim was to review MRI developments relevant for the pediatric larynx and to discuss future imaging options. Methods: A systematic search was conducted to identify all morphological and diagnostic studies in which MRI was used to image the pediatric larynx, laryngeal disease, or vocal cords. Results: Fourteen articles were included: three studies on anatomical imaging of the larynx, two studies on Diffusion Weighted Imaging, four studies on vocal cord imag

    Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique

    Get PDF
    BACKGROUND: Magnetic resonance coronary angiography is challenging because of the motion of the vessels during cardiac contraction and respiration. Additional challenges are the small calibre of the arteries and their complex three dimensional course. Respiratory gating, turboflash acquisition, and volume rendering techniques may meet the necessary requirements for appropriate visualisation. OBJECTIVE: To determine the diagnostic accuracy of respiratory gated magnetic resonance imaging (MRI) for the detection of significant coronary artery stenoses evaluated with three dimensional postprocessing software. METHODS: 32 patients referred for elective coronary angiography were studied with a retrospective respiratory gated three dimensional gradient echo MRI technique. Resolution was 1.9 x 1.25 x 2 mm. After manual segmentation three dimensional evaluation was performed with a volume rendering technique. RESULTS: Overall 74% (range 50% to 90%) of the proximal and mid coronary artery segments were visualised with an image quality suitable for further analysis. Sensitivity and specificity for the detection of significant stenoses were 50% and 91%, respectively. CONCLUSIONS: Volume rendering of respiratory gated MRI techniques allows adequate visualisation of the coronary arteries in patients with a regular breathing pattern. Significant lesions in the major coronary artery branches can be identified with a moderate sensitivity and a high specificity

    MR coronary angiography with breath-hold targeted volumes: preliminary clinical results

    Get PDF
    PURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred for elective coronary angiography were included. The coronary arteries were localized during single-breath-hold, three-dimensional imaging of the entire heart. MR coronary angiography was then performed along the major coronary branches with a double-oblique, three-dimensional, gradient-echo sequence. Conventional coronary angiography was the reference-standard method. RESULTS: Adequate visualization was achieved with MR coronary angiography in 85%-91% of the proximal coronary arterial branches and in 38%-76% of the middle and distal branches. Overall, 187 (69%) of 272 segments were suitable for comparison between conventional and MR coronary angiography. The diagnostic accuracy of MR coronary angiography for the detection of hemodynamically significant stenoses was 92%; sensitivity, 68%; and specificity, 97%. The sensitivity in individual segments was 50%-77%, whereas the specificity was 94%-100%. CONCLUSION: Adequate visualization of the major coronary arterial branches was possible in the majority of patients. The observed accuracy of MR coronary angiography for detection of hemodynamically significant coronary arterial stenosis is promising, but it needs to be higher before this modality can be used reliably in a clinical setting

    The clinical impact of phase offset errors and different correction methods in cardiovascular magnetic resonance phase contrast imaging: a multi-scanner study

    Get PDF
    Background: Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and 2) to evaluate the clinical implications of these methods. Methods: CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue order was determined per scanner and software program. Velo

    Structure and Function of the Vocal Cords after Airway Reconstruction on Magnetic Resonance Imaging

    Get PDF
    Objectives/Hypothesis: Dysphonia is a common problem at long-term follow-up after airway surgery for laryngotracheal stenosis (LTS) with major impact on quality of life. Dysphonia after LTS can be caused by scar tissue from initial stenosis along with anatomical alterations after surgery. There is need for a modality to noninvasively image structure and function of the reconstructed upper airways including the vocal cords to assess voice outcom

    Validation of 4D flow CMR against simultaneous invasive hemodynamic measurements: a swine study

    Get PDF
    The purpose of this study was to compare invasively measured aorta fow with 2D phase contrast fow and 4D fow measurements by cardiovascular magnetic resonance (CMR) imaging in a large animal model. Nine swine (mean weight 63±4 kg) were included in the study. 4D fow CMR exams were performed on a 1.5T MRI scanner. Flow measurements were performed on 4D fow images at the aortic valve level, in the ascending aorta, and main pulmonary artery. Simultaneously, fow was measured using an invasive fow probe, placed around the ascending aorta. Additionally, standard 2D phase contrast fow and 2D left ventricular (LV) volumetric data were used for comparison. The correlations of cardiac output (CO) between the invasive fow probe, and CMR modalities were strong to very strong. CO measured by 4D fow CMR correlated better with the CO measured by the invasive fow probe than 2D fow CMR fow and volumetric LV data (4D fow CMR: Spearman’s rho = 0.86 at the aortic valve level and 0.90 at the ascending aorta level; 2D fow CMR: 0.67 at aortic valve level; LV measurements: 0.77). In addition, there tended to be a correlation between mean pulmonary artery fow and aorta fow with 4D fow (Spearman’s rho=0.65, P=0.07), which was absent in measurements obtained with 2D fow CMR (Spearman’s rho=0.40, P=0.33). This study shows that aorta fow can be accurately measured by 4D fow CMR compared to simultaneously measured invasive fow. This helps to further validate the quantitative reliability of this technique

    Possibility of quantitative T2-mapping MRI of cartilage near metal in high tibial osteotomy: A human cadaver study

    Get PDF
    T2-mapping is a widely used quantitative MRI technique in osteoarthritis research. An important challenge for its application in the context of high tibial osteotomy (HTO) is the presence of metallic fixation devices. In this study, we evaluated the possibility of performing T2-mapping after a HTO, by assessing the extent of magnetic susceptibility artifacts and the influence on T2 relaxation times caused by two commonly used fixation devices. T2-mapping with a 3D fast spin-echo sequence at three Tesla was performed on 11 human cadaveric knee joints before and after implantation of a titanium plate and screws (n = 5) or cobalt chrome staples (n = 6). Mean T2 relaxation times were calculated in six cartila

    Hospital implementation of minimally invasive autopsy: A prospective cohort study of clinical performance and costs

    Get PDF
    Objectives Autopsy rates worldwide have dropped significantly over the last decades and imaging-based autopsies are increasingly used as an alternative to conventional autopsy. Our aim was to evaluate the clinical performance and cost of minimally invasive autopsy. Methods This study was part of a prospective cohort study evaluating a newly implemented minimally invasive autopsy consisting of MRI, CT, and biopsies. We calculated diagnostic yield and clinical utility—defined as the percentage successfully answered clinical questions—of minimally invasive autopsy. We performed minimally invasive autopsy in 46 deceased (30 men, 16 women; mean age 62.9±17.5, min-max: 18–91). Results Ninety-six major diagnoses were found with the minimally invasive autopsy of which 47/96 (49.0%) were new diagnoses. CT found 65/96 (67.7%) major diagnoses and MRI found 82/ 96 (85.4%) major diagnoses. Eighty-four clinical questions were asked in all cases. Seventy-one (84.5%) of these questions could be answered with minimally invasive autopsy. CT successfully answered 34/84 (40.5%) clinical questions; in 23/84 (27.4%) without the need for biopsies, and in 11/84 (13.0%) a biopsy was required. MRI successfully answered 60/84 (71.4%) clinical questions, in 27/84 (32.1%) without the need for biopsies, and in 33/ 84 (39.8%) a biopsy was required. The mean cost of a minimally invasive autopsy was €1296 including brain biopsies and €1087 without brain biopsies. Mean cost of CT was €187 and of MRI €284. Conclusions A minimally invasive autopsy, consisting of CT, MRI and CT-guided biopsies, performs well in answering clinical questions and detecting major diagnoses. However, the diagnostic yield and clinical utility were quite low for postmortem CT and MRI as standalone modalities