82 research outputs found

    Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel–Titanium Stent: Feasibility and Safety Porcine Trial

    Get PDF
    We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel–titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted

    Successful interdisciplinary management of the misdeployment of two self-expanding stents into the internal carotid artery: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>With the widespread use of carotid artery stenting, previously unknown technical mistakes of this treatment modality are now being encountered. There are multiple strategies for the treatment of in-stent restenosis. With regard to surgical management, endarterectomy and patch plasty are favored. To the best of our knowledge, this report is the first description of a complete stent removal by the eversion technique.</p> <p>Case presentation</p> <p>We report the case of a 63-year-old Caucasian man with misdeployment of two stents into his stenotic proximal internal carotid artery, resulting in a high-grade mechanical obstruction of the internal carotid artery lumen. With the contralateral internal carotid artery already occluded and associated stenoses of both proximal and distal vertebral arteries, an interdisciplinary therapeutic concept was applied. Bilateral balloon angioplasty and stenting of the proximal and distal stenotic vertebral arteries were carried out to provide sufficient posterior collateral blood flow, followed by successful surgical stentectomy and carotid endarterectomy using the eversion technique. Duplex scanning and neurological assessments were normal over a 12-month follow-up period.</p> <p>Conclusions</p> <p>Interdisciplinary treatment is a recommended option to protect patients from further impairment. Further evaluation in larger studies is highly recommended.</p

    Bronchial artery embolization for management of massive cryptogenic hemoptysis: a case series

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Hemoptysis constitutes a common and urgent medical problem. Swift and effective management is of crucial importance, especially in severe, life-threatening cases. In cases of idiopathic hemoptysis, in which no underlying pulmonary pathology can be identified, treatment is challenging. We report our experience with bronchial artery embolization in the treatment of massive idiopathic hemoptysis.</p> <p>Cases presentation</p> <p>We report three consecutive cases of acute severe idiopathic hemoptysis. Our patients (two men aged 51 and 56 years and one woman aged 46 years), were of Caucasian ethnicity. We discuss the results and management of the patients, and review the literature. All three patients were treated safely and successfully with transcatheter embolization of the bronchial arteries using tris-acryl gelatin microspheres. Hemoptysis was controlled. All cases were followed up for 12 months, and there was no recurrence of bleeding.</p> <p>Conclusion</p> <p>Bronchial artery embolization is an effective tool for the evaluation and treatment of massive idiopathic hemoptysis.</p

    Canagliflozin attenuates the progression of atherosclerosis and inflammation process in APOE knockout mice

    Get PDF
    Background: Sodium glucose co-transporter2 inhibitors reduce the incidence of cardiovascular events in patients with type 2 diabetes mellitus based on the results of recent cardiovascular outcome studies. Herein, we investigated the efects of long-term treatment with canaglifozin on biochemical and immunohistochemical markers related to atherosclerosis and atherosclerosis development in the aorta of apolipoprotein E knockout (Apo-E(−/−) ) mice. Methods: At the age of 5 weeks, mice were switched from normal to a high-fat diet. After 5 weeks, Apo-E(−/−) mice were divided into control-group (6 mice) treated with 0.5% hydroxypropyl methylcellulose and Cana-group (7 mice) treated with canaglifozin (10 mg/kg per day) per os. After 5 weeks of intervention, animals were sacrifced, and heart and aorta were removed. Sections stained with hematoxylin–eosin (H&E) were used for histomorphometry whereas Masson’s stained tissues were used to quantify the collagen content. Immunohistochemistry to assess MCP-1, CD68, a-smooth muscle actin, MMP-2, MMP-9, TIMP-1 and TIMP-2 expression was carried out and q-PCR experiments were performed to quantify mRNA expression. Results: Canaglifozin-group mice had lower total-cholesterol, triglycerides and glucose levels (P<0.01), while heart rate was signifcantly lower (P<0.05). Histomorphometry revealed that one in seven Cana-group mice versus four in six control mice developed atheromatosis, while aortic root plaque was signifcantly less, and collagen was 1.6 times more intense in canaglifozin-group suggesting increased plaque stability. Immunohistochemistry revealed that MCP-1 was signifcantly less expressed (P<0.05) in the aortic root of canaglifozin-group while reduced expression of a-actin and CD68 was not reaching signifcance (P=0.15). VCAM-1 and MCP-1 mRNA levels were lower (P=0.02 and P=0.07, respectively), while TIMP-1/MMP-2 ratio expression was higher in canaglifozin-group approaching statistical signifcance (P=0.07). Conclusions: Canaglifozin attenuates the progression of atherosclerosis, reducing (1) hyperlipidemia and hyper‑ glycemia, and (2) infammatory process, by lowering the expression of infammatory molecules such as MCP-1 and VCAM-1. Moreover, canaglifozin was found to increase the atherosclerotic plaque stability via increasing TIMP-1/ MMP-2 ratio expression
    corecore