    Quality Control-Driven Image Segmentation Towards Reliable Automatic Image Analysis in Large-Scale Cardiovascular Magnetic Resonance Aortic Cine Imaging

    Get PDF
    “The final authenticated version is available online at https://doi.org/10.1007/978-3-030-32245-8_83.”© 2019, Springer Nature Switzerland AG. Recent progress in fully-automated image segmentation has enabled efficient extraction of clinical parameters in large-scale clinical imaging studies, reducing laborious manual processing. However, the current state-of-the-art automatic image segmentation may still fail, especially when it comes to atypical cases. Visual inspection of segmentation quality is often required, thus diminishing the improvements in efficiency. This drives an increasing need to enhance the overall data processing pipeline with robust automatic quality scoring, especially for clinical applications. We present a novel quality control-driven (QCD) framework to provide reliable segmentation using a set of different neural networks. In contrast to the prior segmentation and quality scoring methods, the proposed framework automatically selects the optimal segmentation on-the-fly from the multiple candidate segmentations available, directly utilizing the inherent Dice similarity coefficient (DSC) predictions. We trained and evaluated the framework on a large-scale cardiovascular magnetic resonance aortic cine image sequences from the UK Biobank Study. The framework achieved segmentation accuracy of mean DSC at 0.966, mean prediction error of DSC within 0.015, and mean error in estimating lumen area ≤17.6 mm2 for both ascending aorta and proximal descending aorta. This novel QCD framework successfully integrates the automatic image segmentation along with detection of critical errors on a per-case basis, paving the way towards reliable fully-automatic extraction of clinical parameters for large-scale imaging studies

    Poor Bone Quality is Associated With Greater Arterial Stiffness: Insights From the UK Biobank

    Get PDF
    Osteoporosis and ischemic heart disease (IHD) represent important public health problems. Existing research suggests an association between the two conditions beyond that attributable to shared risk factors, with a potentially causal relationship. In this study, we tested the association of bone speed of sound (SOS) from quantitative heel ultrasound with (i) measures of arterial compliance from cardiovascular magnetic resonance (aortic distensibility [AD]); (ii) finger photoplethysmography (arterial stiffness index [ASI]); and (iii) incident myocardial infarction and IHD mortality in the UK Biobank cohort. We considered the potential mediating effect of a range of blood biomarkers and cardiometabolic morbidities and evaluated differential relationships by sex, menopause status, smoking, diabetes, and obesity. Furthermore, we considered whether associations with arterial compliance explained association of SOS with ischemic cardiovascular outcomes. Higher SOS was associated with lower arterial compliance by both ASI and AD for both men and women. The relationship was most consistent with ASI, likely relating to larger sample size available for this variable (n = 159,542 versus n = 18,229). There was no clear evidence of differential relationship by menopause, smoking, diabetes, or body mass index (BMI). Blood biomarkers appeared important in mediating the association for both men and women, but with different directions of effect and did not fully explain the observed effects. In fully adjusted models, higher SOS was associated with significantly lower IHD mortality in men, but less robustly in women. The association of SOS with ASI did not explain this observation. In conclusion, our findings support a positive association between bone and vascular health with consistent patterns of association in men and women. The underlying mechanisms are complex and appear to vary by sex

    Quality assurance of quantitative cardiac T1-mapping in multicenter clinical trials - A T1 phantom program from the hypertrophic cardiomyopathy registry (HCMR) study.

    Get PDF
    BACKGROUND: Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials. PURPOSE: To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use. METHODS: MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites. RESULTS: T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R2 > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions. CONCLUSIONS: The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials

    Standardized image post-processing of cardiovascular magnetic resonance T1-mapping reduces variability and improves accuracy and consistency in myocardial tissue characterization

    No full text
    Background: Myocardial T1-mapping is increasingly used in multicentre studies and trials. Inconsistent image analysis introduces variability, hinders differentiation of diseases, and results in larger sample sizes. We present a systematic approach to standardize T1-map analysis by human operators to improve accuracy and consistency. Methods: We developed a multi-step training program for T1-map post-processing. The training dataset contained 42 left ventricular (LV) short-axis T1-maps (normal and diseases; 1.5 and 3 Tesla). Contours drawn by two experienced human operators served as reference for myocardial T1 and wall thickness (WT). Trainees (n = 26) underwent training and were evaluated by: (a) qualitative review of contours; (b) quantitative comparison with reference T1 and WT. Results: The mean absolute difference between reference operators was 8.4 ± 6.3 ms (T1) and 1.2 ± 0.7 pixels (WT). Trainees' mean discrepancy from reference in T1 improved significantly post-training (from 8.1 ± 2.4 to 6.7 ± 1.4 ms; p b 0.001), with a 43% reduction in standard deviation (SD) (p = 0.035). WT also improved significantly post-training (from 0.9 ± 0.4 to 0.7 ± 0.2 pixels, p = 0.036), with 47% reduction in SD (p = 0.04). These experimentally-derived thresholds served to guide the training process: T1 (±8 ms) and WT (±1 pixel) from reference. Conclusion: A standardized approach to CMR T1-map image post-processing leads to significant improvements in the accuracy and consistency of LV myocardial T1 values and wall thickness. Improving consistency between operators can translate into 33–72% reduction in clinical trial sample-sizes. This work may: (a) serve as a basis for re-certification for core-lab operators; (b) translate to sample-size reductions for clinical studies; (c) produce better-quality training datasets for machine learning.</br

    MOCOnet: robust motion correction of cardiovascular magnetic resonance T1 mapping using convolutional neural networks

    No full text
    Background: Quantitative cardiovascular magnetic resonance (CMR) T1 mapping has shown promise for advanced tissue characterisation in routine clinical practise. However, T1 mapping is prone to motion artefacts, which affects its robustness and clinical interpretation. Current methods for motion correction on T1 mapping are model-driven with no guarantee on generalisability, limiting its widespread use. In contrast, emerging data-driven deep learning approaches have shown good performance in general image registration tasks. We propose MOCOnet, a convolutional neural network solution, for generalisable motion artefact correction in T1 maps. Methods: The network architecture employs U-Net for producing distance vector fields and utilises warping layers to apply deformation to the feature maps in a coarse-to-fine manner. Using the UK Biobank imaging dataset scanned at 1.5T, MOCOnet was trained on 1,536 mid-ventricular T1 maps (acquired using the ShMOLLI method) with motion artefacts, generated by a customised deformation procedure, and tested on a different set of 200 samples with a diverse range of motion. MOCOnet was compared to a well-validated baseline multi-modal image registration method. Motion reduction was visually assessed by 3 human experts, with motion scores ranging from 0% (strictly no motion) to 100% (very severe motion). Results: MOCOnet achieved fast image registration (<1 second per T1 map) and successfully suppressed a wide range of motion artefacts. MOCOnet significantly reduced motion scores from 37.1±21.5 to 13.3±10.5 (p < 0.001), whereas the baseline method reduced it to 15.8±15.6 (p < 0.001). MOCOnet was significantly better than the baseline method in suppressing motion artefacts and more consistently (p = 0.007). Conclusion: MOCOnet demonstrated significantly better motion correction performance compared to a traditional image registration approach. Salvaging data affected by motion with robustness and in a time-efficient manner may enable better image quality and reliable images for immediate clinical interpretation

    MOCOnet: robust motion correction of cardiovascular magnetic resonance T1 mapping using convolutional neural networks

    No full text
    Background: Quantitative cardiovascular magnetic resonance (CMR) T1 mapping has shown promise for advanced tissue characterisation in routine clinical practise. However, T1 mapping is prone to motion artefacts, which affects its robustness and clinical interpretation. Current methods for motion correction on T1 mapping are model-driven with no guarantee on generalisability, limiting its widespread use. In contrast, emerging data-driven deep learning approaches have shown good performance in general image registration tasks. We propose MOCOnet, a convolutional neural network solution, for generalisable motion artefact correction in T1 maps. Methods: The network architecture employs U-Net for producing distance vector fields and utilises warping layers to apply deformation to the feature maps in a coarse-to-fine manner. Using the UK Biobank imaging dataset scanned at 1.5T, MOCOnet was trained on 1,536 mid-ventricular T1 maps (acquired using the ShMOLLI method) with motion artefacts, generated by a customised deformation procedure, and tested on a different set of 200 samples with a diverse range of motion. MOCOnet was compared to a well-validated baseline multi-modal image registration method. Motion reduction was visually assessed by 3 human experts, with motion scores ranging from 0% (strictly no motion) to 100% (very severe motion). Results: MOCOnet achieved fast image registration (<1 second per T1 map) and successfully suppressed a wide range of motion artefacts. MOCOnet significantly reduced motion scores from 37.1±21.5 to 13.3±10.5 (p < 0.001), whereas the baseline method reduced it to 15.8±15.6 (p < 0.001). MOCOnet was significantly better than the baseline method in suppressing motion artefacts and more consistently (p = 0.007). Conclusion: MOCOnet demonstrated significantly better motion correction performance compared to a traditional image registration approach. Salvaging data affected by motion with robustness and in a time-efficient manner may enable better image quality and reliable images for immediate clinical interpretation