2,356 research outputs found

    On Using Backpropagation for Speech Texture Generation and Voice Conversion

    Full text link
    Inspired by recent work on neural network image generation which rely on backpropagation towards the network inputs, we present a proof-of-concept system for speech texture synthesis and voice conversion based on two mechanisms: approximate inversion of the representation learned by a speech recognition neural network, and on matching statistics of neuron activations between different source and target utterances. Similar to image texture synthesis and neural style transfer, the system works by optimizing a cost function with respect to the input waveform samples. To this end we use a differentiable mel-filterbank feature extraction pipeline and train a convolutional CTC speech recognition network. Our system is able to extract speaker characteristics from very limited amounts of target speaker data, as little as a few seconds, and can be used to generate realistic speech babble or reconstruct an utterance in a different voice.Comment: Accepted to ICASSP 201

    Presynaptic GABAB receptors inhibit vomeronasal nerve transmission to accessory olfactory bulb mitral cells

    Get PDF
    Vomeronasal sensory neurons (VSNs) recognize pheromonal and kairomonal semiochemicals in the lumen of the vomeronasal organ. VSNs send their axons along the vomeronasal nerve (VN) into multiple glomeruli of the accessory olfactory bulb (AOB) and form glutamatergic synapses with apical dendrites of mitral cells, the projection neurons of the AOB. Juxtaglomerular interneurons release the inhibitory neurotransmitter Îł-aminobutyric acid (GABA). Besides ionotropic GABA receptors, the metabotropic GABAB receptor has been shown to modulate synaptic transmission in the main olfactory system. Here we show that GABAB receptors are expressed in the AOB and are primarily located at VN terminals. Electrical stimulation of the VN provokes calcium elevations in VSN nerve terminals, and activation of GABAB receptors by the agonist baclofen abolishes calcium influx in AOB slice preparations. Patch clamp recordings reveal that synaptic transmission from the VN to mitral cells can be completely suppressed by activation of GABAB receptors. A potent GABAB receptor antagonist, CGP 52432, reversed the baclofen-induced effects. These results indicate that modulation of VSNs via activation of GABAB receptors affects calcium influx and glutamate release at presynaptic terminals and likely balances synaptic transmission at the first synapse of the accessory olfactory system

    Effect of variations in atelectasis on tumor displacement during radiation therapy for locally advanced lung cancer

    Get PDF
    Purpose Atelectasis (AT), or collapsed lung, is frequently associated with central lung tumors. We investigated the variation of atelectasis volumes during radiation therapy and analyzed the effect of AT volume changes on the reproducibility of the primary tumor (PT) position. Methods and materials Twelve patients with lung cancer who had AT and 10 patients without AT underwent repeated 4-dimensional fan beam computed tomography (CT) scans during radiation therapy per protocols that were approved by the institutional review board. Interfraction volume changes of AT and PT were correlated with PT displacements relative to bony anatomy using both a bounding box (BB) method and change in center of mass (COM). Linear regression modeling was used to determine whether PT and AT volume changes were independently associated with PT displacement. PT displacement was compared between patients with and without AT. Results The mean initial AT volume on the planning CT was 189 cm3 (37-513 cm3), and the mean PT volume was 93 cm3 (12-176 cm3). During radiation therapy, AT and PT volumes decreased on average 136.7 cm3 (20-369 cm3) for AT and 40 cm3 (−7 to 131 cm3) for PT. Eighty-three percent of patients with AT had at least one unidirectional PT shift that was greater than 0.5 cm outside of the initial BB during treatment. In patients with AT, the maximum PT COM shift was ≄0.5 cm in all patients and \u3e1 cm in 58% of patients (0.5-2.4 cm). Changes in PT and AT volumes were independently associated with PT displacement (P \u3c .01), and the correlation was smaller with COM (R2 = 0.58) compared with the BB method (R2 = 0.80). The median root mean squared PT displacement with the BB method was significantly less for patients without AT (0.45 cm) compared with those with AT (0.8cm, P = .002). Conclusions Changes in AT and PT volumes during radiation treatment were significantly associated with PT displacements that often exceeded standard setup margins. Repeated 3-dimensional imaging is recommended in patients with AT to evaluate for PT displacements during treatment. Summary This study analyzed 12 patients with atelectasis and 10 patients without atelectasis who underwent repeat 4-dimensional fan beam computed tomography during radiation therapy. Patients with atelectasis had significantly greater tumor displacements than patients without atelectasis, and these tumor displacements often exceeded standard setup margins. Patients with atelectasis may benefit from repeated 3-dimensional imaging during radiation therapy and possible replanning for large tumor displacements

    Effect of variations in atelectasis on tumor displacement during radiation therapy for locally advanced lung cancer

    Get PDF
    Purpose Atelectasis (AT), or collapsed lung, is frequently associated with central lung tumors. We investigated the variation of atelectasis volumes during radiation therapy and analyzed the effect of AT volume changes on the reproducibility of the primary tumor (PT) position. Methods and materials Twelve patients with lung cancer who had AT and 10 patients without AT underwent repeated 4-dimensional fan beam computed tomography (CT) scans during radiation therapy per protocols that were approved by the institutional review board. Interfraction volume changes of AT and PT were correlated with PT displacements relative to bony anatomy using both a bounding box (BB) method and change in center of mass (COM). Linear regression modeling was used to determine whether PT and AT volume changes were independently associated with PT displacement. PT displacement was compared between patients with and without AT. Results The mean initial AT volume on the planning CT was 189 cm3 (37-513 cm3), and the mean PT volume was 93 cm3 (12-176 cm3). During radiation therapy, AT and PT volumes decreased on average 136.7 cm3 (20-369 cm3) for AT and 40 cm3 (−7 to 131 cm3) for PT. Eighty-three percent of patients with AT had at least one unidirectional PT shift that was greater than 0.5 cm outside of the initial BB during treatment. In patients with AT, the maximum PT COM shift was ≄0.5 cm in all patients and \u3e1 cm in 58% of patients (0.5-2.4 cm). Changes in PT and AT volumes were independently associated with PT displacement (P \u3c .01), and the correlation was smaller with COM (R2 = 0.58) compared with the BB method (R2 = 0.80). The median root mean squared PT displacement with the BB method was significantly less for patients without AT (0.45 cm) compared with those with AT (0.8cm, P = .002). Conclusions Changes in AT and PT volumes during radiation treatment were significantly associated with PT displacements that often exceeded standard setup margins. Repeated 3-dimensional imaging is recommended in patients with AT to evaluate for PT displacements during treatment. Summary This study analyzed 12 patients with atelectasis and 10 patients without atelectasis who underwent repeat 4-dimensional fan beam computed tomography during radiation therapy. Patients with atelectasis had significantly greater tumor displacements than patients without atelectasis, and these tumor displacements often exceeded standard setup margins. Patients with atelectasis may benefit from repeated 3-dimensional imaging during radiation therapy and possible replanning for large tumor displacements

    Regionale Innovationspolitik: Konzentration auf Hightech kann in die Irre fĂŒhren

    Get PDF
    Die Bewertung der InnovationsfĂ€higkeit von Regionen hat vor dem Hintergrund des verschĂ€rften regionalen Wettbewerbs um Fördermittel an Bedeutung gewonnen. Zur Bestimmung des regionalen Innovationspotentials werden oftmals einfach zu erhebende Indikatoren wie die Anzahl der Patentanmeldungen aus einer Region oder die innovationsrelevante BeschĂ€ftigung herangezogen. Diese Indikatoren sind jedoch stark auf forschungsintensive Branchen fokussiert und vernachlĂ€ssigen, dass es neben wissenschaftsbasierter Innovation auch die weniger akademische Form der ingenieursbasierten Innovation gibt. Dies birgt die Gefahr fehlgeleiteter innovationspolitischer Maßnahmen, bei denen die HeterogenitĂ€t von Branchen nicht ausreichend berĂŒcksichtigt wird. Solche Strategien sind daher wenig geeignet, regionale Innovationspotentiale - und damit die regionale WettbewerbsfĂ€higkeit - effektiv zu fördern.Regional innovation capacity, Regional innovation policy, Cluster, Knowledge bases
    • 

    corecore