46 research outputs found

    Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting

    Get PDF
    AbstractObjective: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. Methods: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. Results: Baseline characteristics were similar. The number of grafts performed per patient (mean ± SD 3.39 ± 1.04 for off-pump coronary artery bypass grafting, 3.40 ± 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 ± 0.18 for off-pump coronary artery bypass grafting, 1.01 ± 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 ± 6.5 for off-pump coronary artery bypass grafting, 6.1 ± 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. Conclusions: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.J Thorac Cardiovasc Surg 2003;125:797-80

    Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting

    Get PDF
    AbstractObjective: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. Methods: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. Results: Baseline characteristics were similar. The number of grafts performed per patient (mean ± SD 3.39 ± 1.04 for off-pump coronary artery bypass grafting, 3.40 ± 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 ± 0.18 for off-pump coronary artery bypass grafting, 1.01 ± 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 ± 6.5 for off-pump coronary artery bypass grafting, 6.1 ± 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. Conclusions: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.J Thorac Cardiovasc Surg 2003;125:797-80

    New insights into the genetic etiology of Alzheimer's disease and related dementias

    Get PDF
    Characterization of the genetic landscape of Alzheimer's disease (AD) and related dementias (ADD) provides a unique opportunity for a better understanding of the associated pathophysiological processes. We performed a two-stage genome-wide association study totaling 111,326 clinically diagnosed/'proxy' AD cases and 677,663 controls. We found 75 risk loci, of which 42 were new at the time of analysis. Pathway enrichment analyses confirmed the involvement of amyloid/tau pathways and highlighted microglia implication. Gene prioritization in the new loci identified 31 genes that were suggestive of new genetically associated processes, including the tumor necrosis factor alpha pathway through the linear ubiquitin chain assembly complex. We also built a new genetic risk score associated with the risk of future AD/dementia or progression from mild cognitive impairment to AD/dementia. The improvement in prediction led to a 1.6- to 1.9-fold increase in AD risk from the lowest to the highest decile, in addition to effects of age and the APOE Δ4 allele

    Active ingredient contents of 'me-too' registered abamectin products and differences in their efficacy on Tetranychus cinnabarinus

    No full text
    Many agrochemical companies in Turkey purchase generic active ingredients (a.i.) and, by way of 'me-too' registration, sell pesticides under different brand names. Farmers and researchers often claim that these products are ineffective. In order to determine the a.i. content and efficacy of me-too registered abamectin-based products, we studied seven (in 2004) and ten (in 2005) products, which were chosen based on their availability and high market share. Differences in both efficacy and a.i. contents were observed in the products investigated in the study, but making speculative statements that could affect all me-too registered products based on our investigations of only 17 abamectin-based samples is not realistic. TimectinÂź was found to be statistically less effective on Tetranychus cinnabarinus in both laboratory and greenhouse trials than all other tested products. Furthermore, Timectin was determined to have 69.8% less a.i. than in its product specifications. Our findings make it clear that grower complaints about the qualities of agricultural pesticides are based on actual chemical inadequacies of formulated pesticides. Analysis of the a.i. should be carried out as part of regular market inspection in order to determine whether agricultural pesticides comply with their product specifications. In this way growers will be provided with good quality but inexpensive products.Firat University Scientific Research Projects Management UnitWe would like to thank Syngenta, Turkey, for providing the abamectin standard; EBILTEM for providing HPLC to be used in analysis; and Ege University Scientific Research Projects Commission for the financial support they provided for the study. -
    corecore