2,599 research outputs found
Recommended from our members
Current Knowledge and Attitudes Concerning Cost-Effectiveness in Glaucoma Pharmacotherapy: A Glaucoma Specialists Focus Group Study.
Background:Rising healthcare costs motivate continued cost-reduction efforts. To help lower costs associated with open-angle glaucoma (OAG), a prevalent, progressive disease with substantial direct and indirect costs, clinicians need to understand the cost-effectiveness of intraocular pressure (IOP)-lowering pharmacotherapies. There is little published information on clinicians' knowledge and attitudes about cost-effectiveness in glaucoma treatment. Purpose:This pilot focus group study aimed to explore clinician attitudes and perspectives around the costs and cost drivers of glaucoma therapy; the implementation of cost-effectiveness decisions; the clinical utility of cost-effectiveness studies; and the cost-effectiveness of available treatments. Methods:Six US glaucoma specialists participated in two separate teleconferencing sessions (three participants each), managed by an independent, skilled moderator (also a glaucoma specialist) using a discussion guide. Participants reviewed recent publications (n=25) on health economics outcomes research in glaucoma prior to the sessions. Results:Participants demonstrated a clear understanding of the economic burden of glaucoma therapy and identified medications, diagnostics, office visits, and treatment changes as key cost drivers. They considered cost-effectiveness an appropriate component of treatment decision-making but identified the need for additional data to inform these decisions. Participants indicated that there were only a few recent studies on health economics outcomes in glaucoma which evaluate parameters important to patient care, such as quality of life and medication adherence, and that longitudinal data were scant. In addition to efficacy, participants felt patient adherence and side-effect profile should be included in economic evaluations of glaucoma pharmacotherapy. Recently approved medications were evaluated in this context. Conclusion:Clinicians deem treatment decisions based on cost-effectiveness data as clinically appropriate. Newer IOP-lowering therapies with potentially greater efficacy and favorable side-effect and adherence profiles may help optimize cost-effectiveness. Future studies should include: clinicians' perspectives; lack of commercial bias; analysis of long-term outcomes/costs; more comprehensive parameters; real-world (including quality-of-life) data; and a robust Markov model
Structural Change Can Be Detected in Advanced-Glaucoma Eyes.
PurposeTo compare spectral-domain optical coherence tomography (SD-OCT) standard structural measures and a new three-dimensional (3D) volume optic nerve head (ONH) change detection method for detecting change over time in severely advanced-glaucoma (open-angle glaucoma [OAG]) patients.MethodsThirty-five eyes of 35 patients with very advanced glaucoma (defined as a visual field mean deviation < -21 dB) and 46 eyes of 30 healthy subjects to estimate aging changes were included. Circumpapillary retinal fiber layer thickness (cpRNFL), minimum rim width (MRW), and macular retinal ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured using the San Diego Automated Layer Segmentation Algorithm (SALSA). Progression was defined as structural loss faster than 95th percentile of healthy eyes. Three-dimensional volume ONH change was estimated using the Bayesian-kernel detection scheme (BKDS), which does not require extensive retinal layer segmentation.ResultsThe number of progressing glaucoma eyes identified was highest for 3D volume BKDS (13, 37%), followed by GCPIL (11, 31%), cpRNFL (4, 11%), and MRW (2, 6%). In advanced-OAG eyes, only the mean rate of GCIPL change reached statistical significance, -0.18 μm/y (P = 0.02); the mean rates of cpRNFL and MRW change were not statistically different from zero. In healthy eyes, the mean rates of cpRNFL, MRW, and GCIPL change were significantly different from zero. (all P < 0.001).ConclusionsGanglion cell-inner plexiform layer and 3D volume BKDS show promise for identifying change in severely advanced glaucoma. These results suggest that structural change can be detected in very advanced disease. Longer follow-up is needed to determine whether changes identified are false positives or true progression
Recommended from our members
Macular Pigment and Visual Function in Patients With Glaucoma: The San Diego Macular Pigment Study.
PurposeAlthough recent studies have shown that macular pigment (MP) is significantly lower in glaucoma patients, this relationship merits further investigation.MethodsThis cross-sectional study included 85 glaucoma patients and 22 controls. All subjects had standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements. Intake of lutein (L) and zeaxanthin (Z) was estimated using a novel dietary screener. The Heidelberg Spectralis dual-wavelength autofluorescence (AF) technology was employed to study the relationship between MP and glaucoma. The association between MP volume and glaucoma was investigated using linear regression models accounting for potential confounding factors.ResultsGlaucoma patients had significantly worse SAP mean deviation (MD) and lower RNFL thickness in the study eye compared to control subjects (P < 0.001 for both). MP (volume) was comparable between groups (P = 0.436). In the univariable model, diagnosis of glaucoma was not associated with MP volume (R2 = 1.22%; P = 0.257). Dietary intake of L and Z was positively and significantly related to MP in the univariable (P = 0.022) and multivariable (P = 0.020) models.ConclusionsThese results challenge previous studies that reported that glaucoma is associated with low MP. Dietary habits were found to be the main predictor of MP in this sample. Further research is merited to better understand the relationship between glaucoma, MP, and visual performance in these patients
Widely tunable, non-degenerate three-wave mixing microwave device operating near the quantum limit
We present the first experimental realization of a widely frequency tunable,
non-degenerate three-wave mixing device for quantum signals at GHz frequency.
It is based on a new superconducting building-block consisting of a ring of
four Josephson junctions shunted by a cross of four linear inductances. The
phase configuration of the ring remains unique over a wide range of magnetic
fluxes threading the loop. It is thus possible to vary the inductance of the
ring with flux while retaining a strong, dissipation-free, and noiseless
non-linearity. The device has been operated in amplifier mode and its noise
performance has been evaluated by using the noise spectrum emitted by a voltage
biased tunnel junction at finite frequency as a test signal. The unprecedented
accuracy with which the crossover between zero-point-fluctuations and shot
noise has been measured provides an upper-bound for the noise and dissipation
intrinsic to the device.Comment: Accepted for Physical Review Letters. Supplementary material can be
found in the source packag
Synchronous Meteorological Satellite Phase B Study Report
Design of base line system for synchronous meteorological satellit
Retinal Nerve Fiber Layer Features Identified by Unsupervised Machine Learning on Optical Coherence Tomography Scans Predict Glaucoma Progression.
Purpose:To apply computational techniques to wide-angle swept-source optical coherence tomography (SS-OCT) images to identify novel, glaucoma-related structural features and improve detection of glaucoma and prediction of future glaucomatous progression. Methods:Wide-angle SS-OCT, OCT circumpapillary retinal nerve fiber layer (cpRNFL) circle scans spectral-domain (SD)-OCT, standard automated perimetry (SAP), and frequency doubling technology (FDT) visual field tests were completed every 3 months for 2 years from a cohort of 28 healthy participants (56 eyes) and 93 glaucoma participants (179 eyes). RNFL thickness maps were extracted from segmented SS-OCT images and an unsupervised machine learning approach based on principal component analysis (PCA) was used to identify novel structural features. Area under the receiver operating characteristic curve (AUC) was used to assess diagnostic accuracy of RNFL PCA for detecting glaucoma and progression compared to SAP, FDT, and cpRNFL measures. Results:The RNFL PCA features were significantly associated with mean deviation (MD) in both SAP (R2 = 0.49, P < 0.0001) and FDT visual field testing (R2 = 0.48, P < 0.0001), and with mean circumpapillary RNFL thickness (cpRNFLt) from SD-OCT (R2 = 0.58, P < 0.0001). The identified features outperformed each of these measures in detecting glaucoma with an AUC of 0.95 for RNFL PCA compared to an 0.90 for mean cpRNFLt (P = 0.09), 0.86 for SAP MD (P = 0.034), and 0.83 for FDT MD (P = 0.021). Accuracy in predicting progression was also significantly higher for RNFL PCA compared to SAP MD, FDT MD, and mean cpRNFLt (P = 0.046, P = 0.007, and P = 0.044, respectively). Conclusions:A computational approach can identify structural features that improve glaucoma detection and progression prediction
Recommended from our members
The Relative Odds of Progressing by Structural and Functional Tests in Glaucoma.
PurposeThe purpose of this study was to evaluate the effect of disease severity and number of tests acquired during follow-up on the relative odds of identifying progression by structural or functional tests in glaucoma.MethodsThis was an observational cohort study involving 462 eyes of 305 patients with glaucoma and 62 eyes of 49 healthy subjects. Glaucoma patients and healthy subjects were followed for an average of 3.6 ± 0.9 and 3.8 ± 0.9 years, with a median (interquantile range) of 8 (6-9) and 7 (6-8) visits, respectively. At each visit, subjects underwent visual field assessment with standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) evaluation by spectral-domain optical coherence tomography (SD-OCT). Slopes of change in SAP mean sensitivity and OCT RNFL thickness over time were estimated by linear regression using progressively cumulative visits over time. Cutoff values for age-related expected rates of change for each test were obtained from the healthy group. Progression by SD-OCT and/or SAP was determined if the slope of change was statistically significant and also lower (faster) than the fifth percentile cutoff calculated from the healthy group. A generalized estimating equation logistic regression model was used to evaluate the relative odds of progressing by OCT versus SAP in glaucoma eyes.ResultsEyes with less severe disease at baseline had a higher chance of being detected as progressing by SD-OCT but not by SAP, whereas an increase in disease severity at baseline increased the chance that the eye would be detected as progressing by SAP but not SD-OCT. Each 1 dB higher MD was associated with a 5% increase in the odds of detecting progression by SD-OCT versus SAP (odds ratio = 1.05 per 1 dB; 95% confidence interval: 1.01-1.09; P = 0.005).ConclusionsThe ability to detect glaucoma progression by SAP versus SD-OCT is significantly influenced by the stage of disease. Our results may provide useful information for guiding clinicians on the relative utility of these tests for detecting change throughout the disease continuum
W-band 0.3W PHEMT MMIC power amplifier module
A compact (1.8 by 3.0 by 3.8 cm) WR-10 waveguide amplifier module providing 310-mW power output, 20-dB gain, and 5 GHz of 1-dB bandwidth at a center frequency of 96 GHz is described. The module is comprised of 22 identical PHEMT chips, 4-way microstrip power combiners and dividers, and a 4-way waveguide power combiner
Deep-Layer Microvasculature Dropout by Optical Coherence Tomography Angiography and Microstructure of Parapapillary Atrophy.
Purpose:To investigate the association between the microstructure of β-zone parapapillary atrophy (βPPA) and parapapillary deep-layer microvasculature dropout assessed by optical coherence tomography angiography (OCT-A). Methods:Thirty-seven eyes with βPPA devoid of the Bruch's membrane (BM) (γPPA) ranging between completely absent and discontinuous BM were matched by severity of the visual field (VF) damage with 37 eyes with fully intact BM (βPPA+BM) based on the spectral-domain (SD) OCT imaging. Parapapillary deep-layer microvasculature dropout was defined as a dropout of the microvasculature within choroid or scleral flange in the βPPA on the OCT-A. The widths of βPPA, γPPA, and βPPA+BM were measured on six radial SD-OCT images. Prevalence of the dropout was compared between eyes with and without γPPA. Logistic regression was performed for evaluating association of the dropout with the width of βPPA, γPPA, and βPPA+BM, and the γPPA presence. Results:Eyes with γPPA had significantly higher prevalence of the dropout than did those without γPPA (75.7% versus 40.8%; P = 0.004). In logistic regression, presence and longer width of the γPPA, worse VF mean deviation, and presence of focal lamina cribrosa defects were significantly associated with the dropout (P < 0.05), whereas width of the βPPA and βPPA+BM, axial length, and choroidal thickness were not (P > 0.10). Conclusions:Parapapillary deep-layer microvasculature dropout was associated with the presence and larger width of γPPA, but not with the βPPA+BM width. Presence and width of the exposed scleral flange, rather than the retinal pigmented epithelium atrophy, may be associated with deep-layer microvasculature dropout
- …