195 research outputs found

    Thermal simulation modeling of a hydrostatic machine feed platform

    Get PDF
    Hydrostatic guideways are widely applied into precision and ultra-precision machine tools. Meanwhile, the oil film heat transfer causes thermal disturbance to the machine accuracy. Therefore, it is necessary to study the mechanism of the oil film heat transfer and the heat-transfer-reducing method to improve the machine accuracy. This paper describes a comprehensive thermal finite element (FE) simulation modeling method for the hydrostatic machine feed platform to study methods of reducing machine thermal errors. First of all, the generating heat power of viscous hydraulic oil flowing between parallel planes is calculated based on the Bernoulli equation. This calculation is then employed for the simulation load calculations for the closed hydrostatic guideways, which is adopted by the hydrostatic machine feed platform. Especially, in these load calculations, the changing of oil film thickness (resulted from external loads) and the changing of oil dynamic viscosity (influenced by its temperature) are taken into account. Based on these loads, thermal FE simulation modeling of the hydrostatic machine feed platform is completed to predict and analyze its thermal characteristics. The reliability of this simulation modeling method is verified by experiments. The studies demonstrate that the hydrostatic machine thermal error degree is determined by the oil film heat transfer scale, and this scale is mainly influenced by the relative oil supply temperature to ambient temperature (quantitative comparison of oil supply temperature and ambient temperature). Furthermore, the reduction of the absolute value of this relative oil supply temperature can reduce the oil film heat transfer scale and improve the machine accuracy

    A differentiated multi-loops bath recirculation system for precision machine tools

    Get PDF
    Traditional bath recirculation cooler for precision machine tools always has the uniform and open-loop cooling strategy onto different heat generating parts. This causes redundant generated heat being transferred into the machine structure, and results in unsatisfactory thermal errors of precision machine tools. For the solution of this problem, this paper presents the differentiated multi-loops bath recirculation system. The developed system can accomplish differentiated and close-loop cooling strategies onto machine heat generating parts during its operation. Specially, in order to illustrate the advantages of this system, constant supply cooling powers strategy is presented with its applications onto a certain type of built-in motorized spindle. Consequently, advantages of the proposed strategy based on the differentiated multi-loops bath recirculation system are verified experimentally in the environment within consistent temperature (TR = 20 ± 0.3°C). Compared with room temperature tracing strategy based on the traditional bath recirculation cooler, the constant supply cooling powers strategy is verified to be advantageous in spindle temperature stabilization and thermal errors decrease

    Online dosimetric evaluation of larynx SBRT: A pilot study to assess the necessity of adaptive replanning

    Get PDF
    PURPOSE: We have initiated a multi-institutional phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for Stage III-IVa laryngeal cancer. We conducted this pilot dosimetric study to confirm potential utility of online adaptive replanning to preserve treatment quality. METHODS: We evaluated ten cases: five patients enrolled onto the current trial and five patients enrolled onto a separate phase I SBRT trial for early-stage glottic larynx cancer. Baseline SBRT treatment plans were generated per protocol. Daily cone-beam CT (CBCT) or diagnostic CT images were acquired prior to each treatment fraction. Simulation CT images and target volumes were deformably registered to daily volumetric images, the original SBRT plan was copied to the deformed images and contours, delivered dose distributions were re-calculated on the deformed CT images. All of these were performed on a commercial treatment planning system. In-house software was developed to propagate the delivered dose distribution back to reference CT images using the deformation information exported from the treatment planning system. Dosimetric differences were evaluated via dose-volume histograms. RESULTS: We could evaluate dose within 10 minutes in all cases. Prescribed coverage to gross tumor volume (GTV) and clinical target volume (CTV) was uniformly preserved; however, intended prescription dose coverage of planning treatment volume (PTV) was lost in 53% of daily treatments (mean: 93.9%, range: 83.9-97.9%). Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. CONCLUSIONS: Although GTV and CTV SBRT dose coverage is preserved with in-room three-dimensional image guidance, PTV coverage can vary significantly from intended plans and dose to critical structures may exceed tolerances. Online adaptive treatment re-planning is potentially necessary and clinically applicable to fully preserve treatment quality. Confirmatory trial accrual and analysis remains ongoing

    Polyester Usage in Manufacturing of Electrical and Mechanical Products and Assemblies

    Get PDF
    This chapter focuses on the processes in which polyester is usually used for the manufacturing of mechanical components and assemblies. Various methods of manufacturing these products are mentioned in this chapter. These methods include wet layup method, filament winding, pultrusion, vacuum bagging and autoclave curing, resin transfer molding (RTM) and vacuum-assisted resin transfer molding (VARTM). Various production levels and properties can be achieved by polyester resin using abovementioned processes. Each process has its own benefits and disadvantages, which are discussed in this chapter. Furthermore, the use of polyester in making electrical insulation is also discussed in the chapter. Advantages and disadvantages of each impregnation technique are also explained

    Mini percutaneous nephrolithotomy is a noninferior modality to standard percutaneous nephrolithotomy for the management of 20-40 mm renal calculi: A Multicenter randomized controlled trial

    Get PDF
    Background: High quality of evidence comparing mini percutaneous nephrolithotomy (mPNL) with standard percutaneous nephrolithotomy (sPNL) for the treatment of larger-sized renal stones is lacking. Objective: To compare the efficacy and safety of mPNL and sPNL for the treatment of 20–40 mm renal stones. Design, setting, and participants: A parallel, open-label, and noninferior randomized controlled trial was performed at 20 Chinese centers (2016–2019). The inclusion criteria were patients 18–70 yr old, with normal renal function, and 20–40 mm renal stones. Intervention: Percutaneous nephrolithotomy PNL was performed using either 18 F or 24 F percutaneous nephrostomy tracts. Outcome measurements and statistical analysis: The primary outcome was the one-session stone-free rate (SFR). The secondary outcomes included operating time, visual analog pain scale (VAS) score, blood loss, complications as per the Clavien-Dindo grading system, and length of hospitalization. Results and limitations: The 1980 intention-to-treat patients were randomized. The mPNL group achieved a noninferior one-session SFR to the sPNL group by the one-side noninferiority test (0.5% [difference], p < 0.001). The transfusion and embolization rates were comparable; however, the sPNL group had a higher hemoglobin drop (5.2 g/l, p < 0.001). The sPNL yielded shorter operating time (–2.2 min, p = 0.008) but a higher VAS score (0.8, p < 0.001). Patients in the sPNL group also had longer hospitalization (0.6 d, p < 0.001). There was no statistically significant difference in fever or urosepsis occurrences. The study's main limitation was that only 18F or 24F tract sizes were used. Conclusions: Mini mPNL achieves noninferior SFR outcomes to sPNL, but with reduced bleeding, less postoperative pain, and shorter hospitalization. Patient summary: We evaluated the surgical outcomes of percutaneous nephrolithotomy using two different sizes of nephrostomy tracts in a large population. We found that the smaller tract might be a sensible alternative for patients with 20–40 mm renal stones. This multicenter, parallel, open-label, and noninferior randomized controlled trial showed that mini percutaneous nephrolithotomy achieved noninferior stone-free rate with advantages of reduced blood loss, less postoperative pain, and shorter hospitalization. Mini percutaneous nephrolithotomy should be considered a sensible alternative treatment of 20–40 mm renal stones.grants from high-level development funding of Guangzhou Medical Universit

    Neutrino Physics with JUNO

    Get PDF
    The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purposeunderground liquid scintillator detector, was proposed with the determinationof the neutrino mass hierarchy as a primary physics goal. It is also capable ofobserving neutrinos from terrestrial and extra-terrestrial sources, includingsupernova burst neutrinos, diffuse supernova neutrino background, geoneutrinos,atmospheric neutrinos, solar neutrinos, as well as exotic searches such asnucleon decays, dark matter, sterile neutrinos, etc. We present the physicsmotivations and the anticipated performance of the JUNO detector for variousproposed measurements. By detecting reactor antineutrinos from two power plantsat 53-km distance, JUNO will determine the neutrino mass hierarchy at a 3-4sigma significance with six years of running. The measurement of antineutrinospectrum will also lead to the precise determination of three out of the sixoscillation parameters to an accuracy of better than 1\%. Neutrino burst from atypical core-collapse supernova at 10 kpc would lead to ~5000inverse-beta-decay events and ~2000 all-flavor neutrino-proton elasticscattering events in JUNO. Detection of DSNB would provide valuable informationon the cosmic star-formation rate and the average core-collapsed neutrinoenergy spectrum. Geo-neutrinos can be detected in JUNO with a rate of ~400events per year, significantly improving the statistics of existing geoneutrinosamples. The JUNO detector is sensitive to several exotic searches, e.g. protondecay via the pK++νˉp\to K^++\bar\nu decay channel. The JUNO detector will providea unique facility to address many outstanding crucial questions in particle andastrophysics. It holds the great potential for further advancing our quest tounderstanding the fundamental properties of neutrinos, one of the buildingblocks of our Universe

    Potential of Core-Collapse Supernova Neutrino Detection at JUNO

    Get PDF
    JUNO is an underground neutrino observatory under construction in Jiangmen, China. It uses 20kton liquid scintillator as target, which enables it to detect supernova burst neutrinos of a large statistics for the next galactic core-collapse supernova (CCSN) and also pre-supernova neutrinos from the nearby CCSN progenitors. All flavors of supernova burst neutrinos can be detected by JUNO via several interaction channels, including inverse beta decay, elastic scattering on electron and proton, interactions on C12 nuclei, etc. This retains the possibility for JUNO to reconstruct the energy spectra of supernova burst neutrinos of all flavors. The real time monitoring systems based on FPGA and DAQ are under development in JUNO, which allow prompt alert and trigger-less data acquisition of CCSN events. The alert performances of both monitoring systems have been thoroughly studied using simulations. Moreover, once a CCSN is tagged, the system can give fast characterizations, such as directionality and light curve
    corecore