    Oncological Outcomes, Long-Term Toxicities, Quality of Life and Sexual Health after Pencil-Beam Scanning Proton Therapy in Patients with Low-Grade Glioma.

    Get PDF
    PURPOSE To assess oncological outcomes, toxicities, quality of life (QoL) and sexual health (SH) of low-grade glioma (LGG) patients treated with pencil-beam scanning proton therapy (PBS-PT). MATERIAL AND METHODS We retrospectively analyzed 89 patients with LGG (Neurofibromatosis type 1; n = 4 (4.5%) patients) treated with PBS-PT (median dose 54 Gy (RBE)) from 1999 to 2022 at our institution. QoL was prospectively assessed during PBS-PT and yearly during follow-up from 2015 to 2023, while a cross-sectional exploration of SH was conducted in 2023. RESULTS Most LGGs (n = 58; 65.2%) were CNS WHO grade 2 and approximately half (n = 43; 48.3%) were located in the vicinity of the visual apparatus/thalamus. After a median follow-up of 50.2 months, 24 (27%) patients presented with treatment failures and most of these (n = 17/24; 70.8%) were salvaged. The 4-year overall survival was 89.1%. Only 2 (2.2%) and 1 (1.1%) patients presented with CTCAE grade 4 and 3 late radiation-induced toxicity, respectively. No grade 5 late adverse event was observed. The global health as a domain of QoL remained stable and comparable to the reference values during PBS-PT and for six years thereafter. Sexual satisfaction was comparable to the normative population. CONCLUSIONS LGG patients treated with PBS-PT achieved excellent long-term survival and tumor control, with exceptionally low rates of high-grade late toxicity, and favorable QoL and SH

    Universal and dynamic ridge filter for pencil beam scanning particle therapy: a novel concept for ultra-fast treatment delivery.

    Get PDF
    Objective.In pencil beam scanning particle therapy, a short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg peak, to reduce the number of energies and spots required to cover the target volume, thus lowering the treatment time.Approach. Our RF unit comprises two identical RFs placed just before the isocenter. Both RFs move relative to each other, changing the Bragg peak's characteristics dynamically. We simulated different Bragg peak shapes with the RF in Monte Carlo simulation code (TOPAS) and validated them experimentally. We then delivered single-field plans with 1 Gy/fraction to different geometrical targets in water, to measure the dose delivery time using the RF and compare it with the clinical settings.Main results.Aligning the RFs in different positions produces different broadening in the Bragg peak; we achieved a maximum broadening of 2.5 cm. With RF we reduced the number of energies in a field by more than 60%, and the dose delivery time by 50%, for all geometrical targets investigated, without compromising the dose distribution transverse and distal fall-off.Significance. Our novel universal and dynamic RF allows for the adaptation of the Bragg peak broadening for a spot and/or energy layer based on the requirement of dose shaping in the target volume. It significantly reduces the number of energy layers and spots to cover the target volume, and thus the treatment time. This RF design is ideal for ultra-fast treatment delivery within a single breath-hold (5-10 s), efficient delivery of motion mitigation techniques, and small animal irradiation with ultra-high dose rates (FLASH)

    Combined proton-photon therapy for non-small cell lung cancer

    Get PDF
    PURPOSE Advanced non-small cell lung cancer (NSCLC) is still a challenging indication for conventional photon radiotherapy. Proton therapy has the potential to improve outcomes, but proton treatment slots remain a limited resource despite an increasing number of proton therapy facilities. This work investigates the potential benefits of optimally combined proton-photon therapy delivered using a fixed horizontal proton beam line in combination with a photon Linac, which could increase accessibility to proton therapy for such a patient cohort. MATERIALS AND METHODS A treatment planning study has been conducted on a patient cohort of seven advanced NSCLC patients. Each patient had a planning computed tomography scan (CT) and multiple repeated CTs from three different days and for different breath-holds on each day. Treatment plans for combined proton-photon therapy (CPPT) were calculated for individual patients by optimizing the combined cumulative dose on the initial planning CT only (non-adapted) as well as on each daily CT respectively (adapted). The impact of inter-fractional changes and/or breath-hold variability was then assessed on the repeat breath-hold CTs. Results were compared to plans for IMRT or IMPT alone, as well as against combined treatments assuming a proton gantry. Plan quality was assessed in terms of dosimetric, robustness and NTCP metrics. RESULTS Combined treatment plans improved plan quality compared to IMRT treatments, especially in regard to reductions of low and medium doses to organs at risk (OARs), which translated into lower NTCP estimates for three side effects. For most patients, combined treatments achieved results close to IMPT-only plans. Inter-fractional changes impact mainly the target coverage of combined and IMPT treatments, while OARs doses were less affected by these changes. With plan adaptation however, target coverage of combined treatments remained high even when taking variability between breath-holds into account. CONCLUSIONS Optimally combined proton-photon plans improve treatment plan quality compared to IMRT only, potentially reducing the risk of toxicity while also allowing to potentially increase accessibility to proton therapy for NSCLC patients

    Multi-camera optical tracking and fringe pattern analysis for eye surface profilometry in ocular proton therapy.

    Get PDF
    BACKGROUND AND PURPOSE An optical tracking system for high-precision measurement of eye position and orientation during proton irradiation of intraocular tumors was designed. The system performed three-dimensional (3D) topography of the anterior eye segment using fringe pattern analysis based on Fourier Transform Method (FTM). MATERIALS AND METHODS The system consisted of four optical cameras and two projectors. The design and modifications to the FTM pipeline were optimized for the realization of a reliable measurement system. Of note, phase-to-physical coordinate mapping was achieved through the combination of stereo triangulation and fringe pattern analysis. A comprehensive pre-clinical validation was carried out. Then, the system was set to acquire the eye surface of patients undergoing proton therapy. Topographies of the eye were compared to manual contouring on MRI. RESULTS Pre-clinical results demonstrated that 3D topography could achieve sub-millimetric accuracy (median:0.58 mm) and precision (RMSE:0.61 mm) in the clinical setup. The absolute median discrepancy between MRI and FTM-based anterior eye segment surface reconstruction was 0.43 mm (IQR:0.65 mm). CONCLUSIONS The system complied with the requirement of precision and accuracy for image guidance in ocular proton therapy radiation and is expected to be clinically tested soon to evaluate its performance against the current standard

    Dosimetric comparison of autocontouring techniques for online adaptive proton therapy.

    Get PDF
    anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow. Whereas multiple methods for autocontouring exist, none of them are fully accurate, which affects the daily dose. This work aims to quantify the magnitude of this dosimetric effect for four contouring techniques.

Approach: plans reoptimized on automatic contours are compared with plans reoptimized on manual contours. The methods include rigid and deformable registration (DIR), deep-learning based segmentation and patient-specific segmentation.

Results: it was found that independently of the contouring method, the dosimetric influence of using automatic OAR contours is small ( 5% prescribed dose in most cases), indicating that manual verification of that contour remains necessary. However, when compared to non-adaptive therapy, the dose differences caused by automatically contouring the target were small and target coverage was improved, especially for DIR.

Significance: the results show that manual adjustment of OARs is rarely necessary and that several autocontouring techniques are directly usable. Contrarily, manual adjustment of the target is important. This allows prioritizing tasks during time-critical online adaptive proton therapy and therefore supports its further clinical implementation

    MRI and FUNDUS image fusion for improved ocular biometry in Ocular Proton Therapy.

    Get PDF
    INTRODUCTION Ocular biometry in Ocular Proton Therapy (OPT) currently relies on a generic geometrical eye model built by referencing surgically implanted markers. An alternative approach based on image fusion of volumetric Magnetic Resonance Imaging (MRI) and panoramic fundus photography was investigated. MATERIALS AND METHODS Eighteen non-consecutive uveal melanoma (UM) patients, who consented for an MRI and had their tumour base visible on panoramic fundus photography, were included in this comparative analysis. Through generating digitally-reconstructed projections from MRI images using the Lambert azimuthal equal-area projection, 2D-3D image fusion between fundus photography and an eye model delineated on MRI scans was achieved and allowed for a novel definition of the target base (MRI + FCTV). MRI + FCTV was compared with MRI-only delineation (MRIGTV) and the conventional (EyePlan) target definition (EPCTV). RESULTS The combined use of fundus photography and MRI to define tumour volumes reduced the average discrepancies by almost 65% with respect to the MRI only tumour definitions when comparing with the conventionally planned EPCTV. With the proposed method, shallow sub-retinal tumour infiltration, otherwise invisible on MRI, can be included in the target volume definition. Moreover, a novel definition of the fovea location improves the accuracy and personalisation of the 3D eye model. CONCLUSION MRI and fundus image fusion overcomes some of the limitations of ophthalmological MRI for tumour volume definition in OPT. This novel eye tumour modelling method might improve treatment planning personalisation, allowing to better anticipate which patients could benefit from prophylactic treatment protocols for radiation induced maculopathy

    Dosimetric influence of deformable image registration uncertainties on propagated structures for online daily adaptive proton therapy of lung cancer patients

    Get PDF
    Purpose: A major burden of introducing an online daily adaptive proton therapy (DAPT) workflow is the time and resources needed to correct the daily propagated contours. In this study, we evaluated the dosimetric impact of neglecting the online correction of the propagated contours in a DAPT workflow.Material and methods: For five NSCLC patients with nine repeated deep-inspiration breath-hold CTs, proton therapy plans were optimised on the planning CT to deliver 60 Gy-RBE in 30 fractions. All repeated CTs were registered with six different clinically used deformable image registration (DIR) algorithms to the corresponding planning CT. Structures were propagated rigidly and with each DIR algorithm and reference structures were contoured on each repeated CT. DAPT plans were optimised with the uncorrected, propagated structures (propagated DAPT doses) and on the reference structures (ideal DAPT doses), nonadapted doses were recalculated on all repeated CTs.Results: Due to anatomical changes occurring during the therapy, the clinical target volume (CTV) coverage of the non-adapted doses reduces on average by 9.7% (V95) compared to an ideal DAPT doses. For the propagated DAPT doses, the CTV coverage was always restored (average differences in the CTV V95 &lt; 1% compared to the ideal DAPT doses). Hotspots were always reduced with any DAPT approach.Conclusion: For the patients presented here, a benefit of online DAPT was shown, even if the daily optimisation is based on propagated structures with some residual uncertainties. However, a careful (offline) structure review is necessary and corrections can be included in an offline adaption.(c) 2021 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 159 (2021) 136-143 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).</p

    4DMRI-based investigation on the interplay effect for pencil beam scanning proton therapy of pancreatic cancer patients

    Get PDF
    Background: Time-resolved volumetric magnetic resonance imaging (4DMRI) offers the potential to analyze 3D motion with high soft-tissue contrast without additional imaging dose. We use 4DMRI to investigate the interplay effect for pencil beam scanning (PBS) proton therapy of pancreatic cancer and to quantify the dependency of residual interplay effects on the number of treatment fractions. Methods: Based on repeated 4DMRI datasets for nine pancreatic cancer patients, synthetic 4DCTs were generated by warping static 3DCTs with 4DMRI deformation vector fields. 4D dose calculations for scanned proton therapy were performed to quantify the interplay effect by CTV coverage (v95) and dose homogeneity (d5/d95) for incrementally up to 28 fractions. The interplay effect was further correlated to CTV motion characteristics. For quality assurance, volume and mass conservation were evaluated by Jacobian determinants and volume-density comparisons. Results: For the underlying patient cohort with CTV motion amplitudes &lt; 15 mm, we observed significant correlations between CTV motion amplitudes and both the length of breathing cycles and the interplay effect. For individual fractions, tumor underdosage down to v95 = 70% was observed with pronounced dose heterogeneity (d5/d95 = 1.3). For full × 28 fractionated treatments, we observed a mitigation of the interplay effect with increasing fraction numbers. On average, after seven fractions, a CTV coverage with 95–107% of the prescribed dose was reached with sufficient dose homogeneity. For organs at risk, no significant differences were found between the static and accumulated dose plans for 28 fractions. Conclusion: Intrafractional organ motion exhibits a large interplay effect for PBS proton therapy of pancreatic cancer. The interplay effect correlates with CTV motion, but can be mitigated efficiently by fractionation, mainly due to different breathing starting phases in fractionated treatments. For hypofractionated treatments, a further restriction of motion may be required. Repeated 4DMRI measurements are a viable tool for pre- and post-treatment evaluations of the interplay effect

    Maternal outcomes and risk factors for COVID-19 severity among pregnant women.

    Get PDF
    Pregnant women may be at higher risk of severe complications associated with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which may lead to obstetrical complications. We performed a case control study comparing pregnant women with severe coronavirus disease 19 (cases) to pregnant women with a milder form (controls) enrolled in the COVI-Preg international registry cohort between March 24 and July 26, 2020. Risk factors for severity, obstetrical and immediate neonatal outcomes were assessed. A total of 926 pregnant women with a positive test for SARS-CoV-2 were included, among which 92 (9.9%) presented with severe COVID-19 disease. Risk factors for severe maternal outcomes were pulmonary comorbidities [aOR 4.3, 95% CI 1.9-9.5], hypertensive disorders [aOR 2.7, 95% CI 1.0-7.0] and diabetes [aOR2.2, 95% CI 1.1-4.5]. Pregnant women with severe maternal outcomes were at higher risk of caesarean section [70.7% (n = 53/75)], preterm delivery [62.7% (n = 32/51)] and newborns requiring admission to the neonatal intensive care unit [41.3% (n = 31/75)]. In this study, several risk factors for developing severe complications of SARS-CoV-2 infection among pregnant women were identified including pulmonary comorbidities, hypertensive disorders and diabetes. Obstetrical and neonatal outcomes appear to be influenced by the severity of maternal disease
    • 