1,446 research outputs found

    ARE ALTERNATIVE TREATMENTS EFFECTIVE? ISSUES & METHODS INVOLVED IN MEASURING EFFECTIVENESS OF ALTERNATIVE TREATMENTS

    Get PDF
    This paper reviews common research methods which have been used in alternative medicine. We focus on a case series method called the before-after treatment experimental design. How this method can be used by practitioners to measure the effectiveness of their treatments is explored in depth. We address what variables should be measured before, during and after treatment. References to commonly used measurement instruments for physical, emotional and spiritually based variables are included

    Risk of Secondary Malignant Neoplasms From Proton Therapy and Intensity-Modulated X-Ray Therapy for Early-Stage Prostate Cancer

    Get PDF
    Purpose: To assess the risk of a secondary malignant neoplasm (SMN) from proton therapy relative to intensity-modulated radiation therapy (IMRT) using X-rays, taking into account contributions from both primary and secondary sources of radiation, for prostate cancer. Methods and Materials: A proton therapy plan and a 6-MV IMRT plan were constructed for 3 patients with early-stage adenocarcinoma of the prostate. Doses from the primary fields delivered to organs at risk of developing an SMN were determined from treatment plans. Secondary doses from the proton therapy and IMRT were determined from Monte Carlo simulations and available measured data, respectively. The risk of an SMN was estimated from primary and secondary doses on an organ-by-organ basis by use of risk models from the Committee on the Biological Effects of Ionizing Radiation. Results: Proton therapy reduced the risk of an SMN by 26% to 39% compared with IMRT. The risk of an SMN for both modalities was greatest in the in-field organs. However, the risks from the in-field organs were considerably lower with the proton therapy plan than with the IMRT plan. This reduction was attributed to the substantial sparing of the rectum and bladder from exposure to the therapeutic beam by the proton therapy plan. Conclusions: When considering exposure to primary and secondary radiation, proton therapy can reduce the risk of an SMN in prostate patients compared with contemporary IMRT. © 2009 Elsevier Inc. All rights reserved

    High performance WR-1.5 corrugated horn based on stacked rings

    Full text link
    We present the development and characterisation of a high frequency (500-750 GHz) corrugated horn based on stacked rings. A previous horn design, based on a Winston profile, has been adapted for the purpose of this manufacturing process without noticeable RF degradation. A subset of experimental results obtained using a vector network analyser are presented and compared to the predicted performance. These first results demonstrate that this technology is suitable for most commercial applications and also astronomical receivers in need of horn arrays at high frequencies.Comment: 9 page

    Dekonstruktion af Placebo Effekten og fundet af Betydningsrespons

    Get PDF
    We provide a new perspect ve with which to understand what for a half century has been known as the »placebo effect.« We argue that, as currently used, the concept includes much that has nothing to do with placebos, confusirig the most interesting and important aspects of the phenomenon. We propose a new way to understand those aspects of medical care, plus a broad range of additional human experiences, by focusing on the idea of »meaning,« to which people, when they are sick, often respond. We review several of the many areas in medicine in which meaning affects illness or healing and introduce the idea of the »meaning response.« We suggest that use of this formulation, rather than the fixation on inert placebos, will probably lead to far greater insight into how treatment works and perhaps to real improvements in human well-being

    A systematic review of the quality of homeopathic clinical trials

    Get PDF
    BACKGROUND: While a number of reviews of homeopathic clinical trials have been done, all have used methods dependent on allopathic diagnostic classifications foreign to homeopathic practice. In addition, no review has used established and validated quality criteria allowing direct comparison of the allopathic and homeopathic literature. METHODS: In a systematic review, we compared the quality of clinical-trial research in homeopathy to a sample of research on conventional therapies using a validated and system-neutral approach. All clinical trials on homeopathic treatments with parallel treatment groups published between 1945–1995 in English were selected. All were evaluated with an established set of 33 validity criteria previously validated on a broad range of health interventions across differing medical systems. Criteria covered statistical conclusion, internal, construct and external validity. Reliability of criteria application is greater than 0.95. RESULTS: 59 studies met the inclusion criteria. Of these, 79% were from peer-reviewed journals, 29% used a placebo control, 51% used random assignment, and 86% failed to consider potentially confounding variables. The main validity problems were in measurement where 96% did not report the proportion of subjects screened, and 64% did not report attrition rate. 17% of subjects dropped out in studies where this was reported. There was practically no replication of or overlap in the conditions studied and most studies were relatively small and done at a single-site. Compared to research on conventional therapies the overall quality of studies in homeopathy was worse and only slightly improved in more recent years. CONCLUSIONS: Clinical homeopathic research is clearly in its infancy with most studies using poor sampling and measurement techniques, few subjects, single sites and no replication. Many of these problems are correctable even within a "holistic" paradigm given sufficient research expertise, support and methods

    Estimate of the uncertainties in the relative risk of secondary malignant neoplasms following proton therapy and intensity-modulated photon therapy

    Get PDF
    Theoretical calculations have shown that proton therapy can reduce the incidence of radiation-induced secondary malignant neoplasms (SMN) compared with photon therapy for patients with prostate cancer. However, the uncertainties associated with calculations of SMN risk had not been assessed. The objective of this study was to quantify the uncertainties in projected risks of secondary cancer following contemporary proton and photon radiotherapies for prostate cancer. We performed a rigorous propagation of errors and several sensitivity tests to estimate the uncertainty in the ratio of relative risk (RRR) due to the largest contributors to the uncertainty: the radiation weighting factor for neutrons, the dose-response model for radiation carcinogenesis and interpatient variations in absorbed dose. The interval of values for the radiation weighting factor for neutrons and the dose-response model were derived from the literature, while interpatient variations in absorbed dose were taken from actual patient data. The influence of each parameter on a baseline RRR value was quantified. Our analysis revealed that the calculated RRR was insensitive to the largest contributors to the uncertainty. Uncertainties in the radiation weighting factor for neutrons, the shape of the dose-risk model and interpatient variations in therapeutic and stray doses introduced a total uncertainty of 33% to the baseline RRR calculation. © 2010 Institute of Physics and Engineering in Medicine

    Dose perturbations from implanted helical gold markers in proton therapy of prostate cancer

    Get PDF
    Implanted gold fiducial markers are widely used in radiation therapy to improve targeting accuracy. Recent investigations have revealed that metallic fiducial markers can cause severe perturbations in dose distributions for proton therapy, suggesting smaller markers should be considered. The objective of this study was to estimate the dosimetric impact of small gold markers in patients receiving proton therapy for prostate cancer. Small, medium, and large helical wire markers with lengths of 10 mm and helix diameters of 0.35 mm, 0.75 mm, and 1.15 mm, respectively, were implanted in an anthropomorphic phantom. Radiographic visibility was confirmed using a kilovoltage x-ray imaging system, and dose perturbations were predicted from Monte Carlo simulations and confirmed by measurements. Monte Carlo simulations indicated that size of dose perturbation depended on marker size, orientation, and distance from the beam\u27s end of range. Specifically, the perturbation of proton dose for the lateral-opposed-pair treatment technique was 31% for large markers and 23% for medium markers in a typical oblique orientation. Results for perpendicular and parallel orientations were respectively lower and higher. Consequently, these markers are not well suited for use in patients receiving proton therapy for prostate cancer. Dose perturbation was not observed for the small markers, but these markers were deemed too fragile for transrectal implantation in the prostate
    • …
    corecore