17 research outputs found

    Implementation of Novel Quality Assurance Program for Hepatitis C Viral Load Point of Care Testing

    No full text
    All patients should have access to accurate and timely test results. The introduction of point of care testing (PoCT) for infectious diseases has facilitated access to those unable to access traditional laboratory-based medical testing, including those living in remote and regional locations, or individuals who are marginalized or incarcerated individuals. In many countries, laboratory testing for infectious diseases, such as hepatitis C virus (HCV), is performed in a highly regulated environment. However, this is not the case for PoCT, where testing is performed by non-laboratory staff and quality controls are often lacking. An assessment of the provision of laboratory-based quality assurance to PoCT for infectious disease was conducted and the barriers to participation identified. A novel approach to providing quality assurance to PoCT sites, in particular those testing for HCV, was designed and piloted. This novel approach incudes identifying and validating sample types that are inactivated and stable at ambient temperature, creating cost-effective supply chains to facilitate logistics of samples, and the development of a smart phone-enabled portal for data entry and analyses. The creation and validation of this approach to quality assurance of PoCT removes the barriers to participation and acts to improve the quality and accuracy of testing, reduce errors and waste, and improve patient outcomes

    Evaluation of Three Immunoassays Used for Detection of Anti-Rubella Virus Immunoglobulin M Antibodies

    No full text
    Three automated assays (Abbott AxSYM, Bayer ADVIA Centaur, and bioMerieux VIDAS) used for the detection of rubella virus-specific immunoglobulin M were evaluated. A total of 57 samples from individuals with evidence of infection with rubella virus were used to estimate sensitivity, and 220 samples from blood donors and individuals attending an antenatal clinic who had no evidence of recent infection were used to estimate specificity. Seroconversion panels comprising an additional 31 samples from four individuals were used to determine clinical sensitivity. Samples containing potentially cross-reacting substances were also tested. The sensitivities of the three assays ranged from 84.2 to 96.5%, and the specificities ranged from 96.8 to 99.9%. The Abbott AxSYM assay detected more reactive samples than the other two assays when a panel of 57 positive samples was tested. Bayer ADVIA Centaur detected more reactive samples in the seroconversion panels than the other two assays. All three assays evaluated reported a reactive result in 1 or more of the 48 samples containing potentially cross-reacting analytes. The assays demonstrated comparable performance in testing of a well-characterized panel of samples

    Response to Tony Badrick regarding "Letter to the Editor regarding the article by Wayne J. Dimech et al. Time to address quality control processes applied to antibody testing for infectious diseases. Clin Chem Lab Med 2023; 61(2): 205-212 by"

    No full text
    Response to Tony Badrick regarding "Letter to the Editor regarding the article by Wayne J. Dimech et al. Time to address quality control processes applied to antibody testing for infectious diseases

    Validation of assembled nucleic acid-based tests in diagnostic microbiology laboratories

    No full text
    Medical microbiology and virology laboratories use nucleic acid tests (NAT) to detect genomic material of infectious organisms in clinical samples. Laboratories choose to perform assembled (or in-house) NAT if commercial assays are not available or if assembled NAT are more economical or accurate. One reason commercial assays are more expensive is because extensive validation is necessary before the kit is marketed, as manufacturers must accept liability for the performance of their assays, assuming their instructions are followed. On the other hand, it is a particular laboratory's responsibility to validate an assembled NAT prior to using it for testing and reporting results on human samples. There are few published guidelines for the validation of assembled NAT. One procedure that laboratories can use to establish a validation process for an assay is detailed in this document. Before validating a method, laboratories must optimise it and then document the protocol. All instruments must be calibrated and maintained throughout the testing process. The validation process involves a series of steps including: (i) testing of dilution series of positive samples to determine the limits of detection of the assay and their linearity over concentrations to be measured in quantitative NAT; (ii) establishing the day-to-day variation of the assay's performance; (iii) evaluating the sensitivity and specificity of the assay as far as practicable, along with the extent of cross-reactivity with other genomic material; and (iv) assuring the quality of assembled assays using quality control procedures that monitor the performance of reagent batches before introducing new lots of reagent for testing

    Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008-2010

    Get PDF
    Background: Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue.Methods: The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted.Results: From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively).Conclusions: The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group. © 2014 Dimech et al.; licensee BioMed Central Ltd

    Time to address quality control processes applied to antibody testing for infectious diseases

    No full text
    As testing for infectious diseases moves from manual, biological testing such as complement fixation to high throughput automated autoanalyzer, the methods for controlling these assays have also changed to reflect those used in clinical chemistry. However, there are many differences between infectious disease serology and clinical chemistry testing, and these differences have not been considered when applying traditional quality control methods to serology. Infectious disease serology, which is highly regulated, detects antibodies of varying classes and to multiple and different antigens that change according to the organisms' genotype/serotype and stage of disease. Although the tests report a numerical value (usually signal to cut-off), they are not measuring an amount of antibodies, but the intensity of binding within the test system. All serology assays experience lot-to-lot variation, making the use of quality control methods used in clinical chemistry inappropriate. In many jurisdictions, the use of the manufacturer-provided kit controls is mandatory to validate the test run. Use of third-party controls, which are highly recommended by ISO 15189 and the World Health Organization, must be manufactured in a manner whereby they have minimal lot-to-lot variation and at a level where they detect exceptional variation. This paper outlines the differences between clinical chemistry and infectious disease serology and offers a range of recommendations when addressing the quality control of infectious disease serology

    Low genetic diversity of hepatitis B virus surface gene amongst Australian blood donors

    No full text
    Variants in the small surface gene of hepatitis B virus (HBV), which codes for viral surface antigen (HBsAg), can affect the efficacy of HBsAg screening assays and can be associated with occult HBV infection (OBI). This study aimed to characterise the molecular diversity of the HBV small surface gene from HBV-reactive Australian blood donors. HBV isolates from 16 HBsAg-positive Australian blood donors’ plasma were sequenced and genotyped by phylogenies of viral coding genes and/or whole genomes. An analysis of the genetic diversity of eight HBV small surface genes from our 16 samples was conducted and compared with HBV sequences from NCBI of 164 international (non-Australian) blood donors. Genotypes A–D were identified in our samples. The region of HBV small surface gene that contained the sequence encoding the ‘a’ determinant had a greater genetic diversity than the remaining part of the gene. No escape mutants or OBI-related variants were observed in our samples. Variant call analysis revealed two samples with a nucleotide deletion leading to truncation of polymerase and/or large/middle surface amino acid sequences. Overall, we found that HBV small surface gene sequences from Australian donors demonstrated a lower level of genetic diversity than those from non-Australian donor population included in the study.</p