6,917 research outputs found

    High-tip-speed, low-loading transonic fan stage. Part 3: Final report

    Get PDF
    Tests were conducted on a high-tip-speed, low-loading transonic fan stage to determine the performance and inlet flow distortion tolerance of the design. The fan was designed for high efficiency at a moderate pressure ratio by designing the hub section to operate at minimum loss when the tip operates with an oblique shock. The design objective was an efficiency of 86 percent at a pressure ratio of 1.5, a specific flow (flow per unit annulus area) of 42 lb/sec-sq. ft (205.1 kgm/sec-m sq), and a tip speed of 1600 ft/sec (488.6 m/sec). During testing, a peak efficiency of 84 percent was achieved at design speed and design specific flow. At the design speed and pressure ratio, the flow was 4 percent greater than design, efficiency was 81 percent, and a stall margin of 24 percent was obtained. The stall line was improved with hub radial distortion but was reduced when the stage was tested with tip radial and circumferential flow distortions. Blade-to-blade values of static pressures were measured over the rotor blade tips

    Hightip-speed, low-loading transonic fan stage. Part 2: Data compilation

    Get PDF
    Tests were conducted on a high-tip-speed low-loading transonic fan stage to determine the performance and inlet flow distortion tolerance of the design. Test data were recorded for overall and blade element performance with both uniform and distorted inlet flows. A tabular summary of the data and a representative selection of the computer data reduction sheets are presented

    Small axial compressor technology, volume 1

    Get PDF
    A scaled single-stage, highly-loaded, axial-flow transonic compressor was tested at speeds from 70 to 110% design equivalent speed to evaluate the effects of scaling compromises and the individual and combined effects of rotor tip running clearance and rotor shroud casing treatment on the overall and blade element performance. At design speed and 1% tip clearance the stage demonstrated an efficiency of 83.2% at 96.4% design flow and a pressure ratio of 1.865. Casing treatment increased design speed surge margin 2.0 points to 12.8%. Overall performance was essentially unchanged. An increase in rotor running clearance to 2.2%, with smooth casing, reduced design speed peak efficiency 5.7 points, flow by 7.4%, pressure ratio to 1.740, and surge margin to 5.4%. Reinstalling casing treatment regained 3.5 points in design speed peak efficiency, 4.7% flow, increased pressure ratio to 1.800 and surge margin to 8.7%

    Photon counting compressive depth mapping

    Get PDF
    We demonstrate a compressed sensing, photon counting lidar system based on the single-pixel camera. Our technique recovers both depth and intensity maps from a single under-sampled set of incoherent, linear projections of a scene of interest at ultra-low light levels around 0.5 picowatts. Only two-dimensional reconstructions are required to image a three-dimensional scene. We demonstrate intensity imaging and depth mapping at 256 x 256 pixel transverse resolution with acquisition times as short as 3 seconds. We also show novelty filtering, reconstructing only the difference between two instances of a scene. Finally, we acquire 32 x 32 pixel real-time video for three-dimensional object tracking at 14 frames-per-second.Comment: 16 pages, 8 figure

    High-Tip-Speed, Low-Loading Transonic Fan Stage. Part 1: Aerodynamic and Mechanical Design

    Get PDF
    A high-tip-speed, low-loading transonic fan stage was designed to deliver an overall pressure ratio of 1.5 with an adiabatic efficiency of 86 percent. The design flow per unit annulus area is 42.0 pounds per square foot. The fan features a hub/tip ratio of 0.46, a tip diameter of 28.74 in. and operates at a design tip speed of 1600 fps. For these design conditions, the rotor blade tip region operates with supersonic inlet and supersonic discharge relative velocities. A sophisticated quasi-three-dimensional characteristic section design procedure was used for the all-supersonic sections and the inlet of the midspan transonic sections. For regions where the relative outlet velocities are supersonic, the blade operates with weak oblique shocks only

    Application of holography to flow visualization within rotating compressor blade row

    Get PDF
    Two holographic interblade row flow visualization systems were designed to determine the three-dimensional shock patterns and velocity distributions within the rotating blade row of a transonic fan rotor, utilizing the techniques of pulsed laser transmission holography. Both single- and double-exposure bright field holograms and dark field scattered-light holograms were successfully recorded. Two plastic windows were installed in the rotor tip casing and outer casing forward of the rotor to view the rotor blade passage. The viewing angle allowed detailed investigation of the leading edge shocks and shocks in the midspan damper area; limited details of the trailing edge shocks also were visible. A technique was devised for interpreting the reconstructed holograms by constructing three dimensional models that allowed identification of the major shock systems. The models compared favorably with theoretical predictions and results of the overall and blade element data. Most of the holograms were made using the rapid double-pulse technique

    Southwest Research Institute assistance to NASA in biomedical areas of the technology utilization program Final report, 1 Nov. 1967 - 30 Nov. 1968

    Get PDF
    Southwest Research Institute activities in technology utilization program in biomedical areas, Nov. 1967 - Nov. 196

    Small axial compressor technology, volume 2

    Get PDF
    Complete computer printout data are presented and supporting tests discussed in Volume I

    Cross-Cultural Understanding of Health Assessments for People with Intellectual Disability: An Australian resource in the Philippines

    Get PDF
    The Convention on the Rights of Persons with Disabilities has resulted in the involvement of high income countries in international development assistance to people with disabilities in low and middle income countries.  Healthcare tools designed in high income countries and delivered in low and middle income countries may not be appropriate to the context of the lives of people with disabilities.  We undertook a short qualitative study of participants’ views of an Australian-designed comprehensive health assessment tool, with participation from a WHO-Collaborating non-government organisation in regional Philippines. We also examined the participants’ perceptions of the barriers to healthcare for Filipinos with intellectual disabilities.  Responses to the comprehensive health assessment tool were positive although participants agreed that both linguistic and cultural translation would enhance wider use of the tool. The barriers identified included poverty, family isolation, stigma and communication issues as preventing appropriate healthcare delivery to Filipinos with intellectual disability. Consideration must be given to the complexities of transference of healthcare resources to a low and middle income country context, as well as the systemic and cultural barriers to appropriate healthcare provision to people with disabilities
    • …
    corecore