722 research outputs found

    Least Squares Estimator for Vasicek Model Driven by Fractional Levy Processes

    Get PDF
    In this paper, we consider parameter estimation problem for Vasicek model driven by fractional lévy processes defined We construct least squares estimator for drift parameters based on time?continuous observations, the consistency and asymptotic distribution of these estimators are studied in the non?ergodic case. In contrast to the fractional Vasicek model, it can be regarded as a Lévy generalization of fractional Vasicek model

    Effect of Zn doping on magnetic order and superconductivity in LaFeAsO

    Get PDF
    We report Zn-doping effect in the parent and F-doped LaFeAsO oxy-arsenides. Slight Zn doping in LaFe1x_{1-x}Znx_{x}AsO drastically suppresses the resistivity anomaly around 150 K associated with the antiferromagnetic (AFM) spin density wave (SDW) in the parent compound. The measurements of magnetic susceptibility and thermopower confirm further the effect of Zn doping on AFM order. Meanwhile Zn doping does not affect or even enhances the TcT_c of LaFe1x_{1-x}Znx_{x}AsO0.9_{0.9}F0.1_{0.1}, in contrast to the effect of Zn doping in high-TcT_c cuprates. We found that the solubility of Zn content (xx) is limited to less than 0.1 in both systems and further Zn doping (i.e., xx \geq 0.1) causes phase separation. Our study clearly indicates that the non-magnetic impurity of Zn2+^{2+} ions doped in the Fe2_2As2_2 layers affects selectively the AFM order, and superconductivity remains robust against the Zn doping in the F-doped superconductors.Comment: 7 figures, 13 pages; revised version with more dat

    Retinal oscillations carry visual information to cortex

    Get PDF
    Thalamic relay cells fire action potentials that transmit information from retina to cortex. The amount of information that spike trains encode is usually estimated from the precision of spike timing with respect to the stimulus. Sensory input, however, is only one factor that influences neural activity. For example, intrinsic dynamics, such as oscillations of networks of neurons, also modulate firing pattern. Here, we asked if retinal oscillations might help to convey information to neurons downstream. Specifically, we made whole-cell recordings from relay cells to reveal retinal inputs (EPSPs) and thalamic outputs (spikes) and analyzed these events with information theory. Our results show that thalamic spike trains operate as two multiplexed channels. One channel, which occupies a low frequency band (<30 Hz), is encoded by average firing rate with respect to the stimulus and carries information about local changes in the image over time. The other operates in the gamma frequency band (40-80 Hz) and is encoded by spike time relative to the retinal oscillations. Because these oscillations involve extensive areas of the retina, it is likely that the second channel transmits information about global features of the visual scene. At times, the second channel conveyed even more information than the first.Comment: 21 pages, 10 figures, submitted to Frontiers in Systems Neuroscienc

    Short-Wave Near-Infrared Spectrometer for Alcohol Determination and Temperature Correction

    Get PDF
    A multichannel short-wave near-infrared (SW-NIR) spectrometer module based on charge-coupled device (CCD) detection was designed. The design relied on a tungsten lamp enhanced by light emitting diodes, a fixed grating monochromator and a linear CCD array. The main advantages were high optical resolution and an optimized signal-to-noise ratio (0.24 nm and 500, resp.) in the whole wavelength range of 650 to 1100 nm. An application to alcohol determination using partial least squares calibration and the temperature correction was presented. It was found that the direct transfer method had significant systematic prediction errors due to temperature effect. Generalized least squares weighting (GLSW) method was utilized for temperature correction. After recalibration, the RMSEP found for the 25°C model was 0.53% v/v and errors of the same order of magnitude were obtained at other temperatures (15, 35 and 40°C). And an r2 better than 0.99 was achieved for each validation set. The possibility and accuracy of using the miniature SW-NIR spectrometer and GLSW transfer calibration method for alcohol determination at different temperatures were proven. And the analysis procedure was simple and fast, allowing a strict control of alcohol content in the wine industry
    corecore