722 research outputs found
Least Squares Estimator for Vasicek Model Driven by Fractional Levy Processes
In this paper, we consider parameter estimation problem for Vasicek model driven by fractional lévy processes defined
We construct least squares estimator for drift parameters based on time?continuous observations, the consistency and asymptotic distribution of these estimators are studied in the non?ergodic case. In contrast to the fractional Vasicek model, it can be regarded as a Lévy generalization of fractional Vasicek model
Effect of Zn doping on magnetic order and superconductivity in LaFeAsO
We report Zn-doping effect in the parent and F-doped LaFeAsO oxy-arsenides.
Slight Zn doping in LaFeZnAsO drastically suppresses the
resistivity anomaly around 150 K associated with the antiferromagnetic (AFM)
spin density wave (SDW) in the parent compound. The measurements of magnetic
susceptibility and thermopower confirm further the effect of Zn doping on AFM
order. Meanwhile Zn doping does not affect or even enhances the of
LaFeZnAsOF, in contrast to the effect of Zn
doping in high- cuprates. We found that the solubility of Zn content ()
is limited to less than 0.1 in both systems and further Zn doping (i.e.,
0.1) causes phase separation. Our study clearly indicates that the
non-magnetic impurity of Zn ions doped in the FeAs layers
affects selectively the AFM order, and superconductivity remains robust against
the Zn doping in the F-doped superconductors.Comment: 7 figures, 13 pages; revised version with more dat
Retinal oscillations carry visual information to cortex
Thalamic relay cells fire action potentials that transmit information from
retina to cortex. The amount of information that spike trains encode is usually
estimated from the precision of spike timing with respect to the stimulus.
Sensory input, however, is only one factor that influences neural activity. For
example, intrinsic dynamics, such as oscillations of networks of neurons, also
modulate firing pattern. Here, we asked if retinal oscillations might help to
convey information to neurons downstream. Specifically, we made whole-cell
recordings from relay cells to reveal retinal inputs (EPSPs) and thalamic
outputs (spikes) and analyzed these events with information theory. Our results
show that thalamic spike trains operate as two multiplexed channels. One
channel, which occupies a low frequency band (<30 Hz), is encoded by average
firing rate with respect to the stimulus and carries information about local
changes in the image over time. The other operates in the gamma frequency band
(40-80 Hz) and is encoded by spike time relative to the retinal oscillations.
Because these oscillations involve extensive areas of the retina, it is likely
that the second channel transmits information about global features of the
visual scene. At times, the second channel conveyed even more information than
the first.Comment: 21 pages, 10 figures, submitted to Frontiers in Systems Neuroscienc
Short-Wave Near-Infrared Spectrometer for Alcohol Determination and Temperature Correction
A multichannel short-wave near-infrared (SW-NIR) spectrometer module based on charge-coupled device (CCD) detection was designed. The design relied on a tungsten lamp enhanced by light emitting diodes, a fixed grating monochromator and a linear CCD array. The main advantages were high optical resolution and an optimized signal-to-noise ratio (0.24 nm and 500, resp.) in the whole wavelength range of 650 to 1100 nm. An application to alcohol determination using partial least squares calibration and the temperature correction was presented. It was found that the direct transfer method had significant systematic prediction errors due to temperature effect. Generalized least squares weighting (GLSW) method was utilized for temperature correction. After recalibration, the RMSEP found for the 25°C model was 0.53% v/v and errors of the same order of magnitude were obtained at other temperatures (15, 35 and 40°C). And an r2 better than 0.99 was achieved for each validation set. The possibility and accuracy of using the miniature SW-NIR spectrometer and GLSW transfer calibration method for alcohol determination at different temperatures were proven. And the analysis procedure was simple and fast, allowing a strict control of alcohol content in the wine industry
- …