27 research outputs found
Arm-length stabilisation for interferometric gravitational-wave detectors using frequency-doubled auxiliary lasers
Residual motion of the arm cavity mirrors is expected to prove one of the
principal impediments to systematic lock acquisition in advanced
gravitational-wave interferometers. We present a technique which overcomes this
problem by employing auxiliary lasers at twice the fundamental measurement
frequency to pre-stabilise the arm cavities' lengths. Applying this approach,
we reduce the apparent length noise of a 1.3 m long, independently suspended
Fabry-Perot cavity to 30 pm rms and successfully transfer longitudinal control
of the system from the auxiliary laser to the measurement laser
DC readout experiment in Enhanced LIGO
The two 4 km long gravitational wave detectors operated by the Laser
Interferometer Gravitational-wave Observatory (LIGO) were modified in 2008 to
read out the gravitational wave channel using the DC readout form of homodyne
detection and to include an optical filter cavity at the output of the
detector. As part of the upgrade to Enhanced LIGO, these modifications replaced
the radio-frequency (RF) heterodyne system used previously. We describe the
motivations for and the implementation of DC readout and the output mode
cleaner in Enhanced LIGO. We present characterizations of the system, including
measurements and models of the couplings of the noises from the laser source to
the gravitational wave readout channel. We show that noise couplings using DC
readout are improved over those for RF readout, and we find that the achieved
shot-noise-limited sensitivity is consistent with modeled results
Searching for stochastic gravitational waves using data from the two colocated LIGO Hanford detectors
Searches for a stochastic gravitational-wave background (SGWB) using terrestrial detectors typically involve cross-correlating data from pairs of detectors. The sensitivity of such cross-correlation analyses depends, among other things, on the separation between the two detectors: the smaller the separation, the better the sensitivity. Hence, a colocated detector pair is more sensitive to a gravitational-wave background than a noncolocated detector pair. However, colocated detectors are also expected to suffer from correlated noise from instrumental and environmental effects that could contaminate the measurement of the background. Hence, methods to identify and mitigate the effects of correlated noise are necessary to achieve the potential increase in sensitivity of colocated detectors. Here we report on the first SGWB analysis using the two LIGO Hanford detectors and address the complications arising from correlated environmental noise. We apply correlated noise identification and mitigation techniques to data taken by the two LIGO Hanford detectors, H1 and H2, during LIGO’s fifth science run. At low frequencies, 40–460 Hz, we are unable to sufficiently mitigate the correlated noise to a level where we may confidently measure or bound the stochastic gravitational-wave signal. However, at high frequencies, 460–1000 Hz, these techniques are sufficient to set a 95% confidence level upper limit on the gravitational-wave energy density of Ω(f) < 7.7 × 10[superscript -4](f/900 Hz)[superscript 3], which improves on the previous upper limit by a factor of ~180. In doing so, we demonstrate techniques that will be useful for future searches using advanced detectors, where correlated noise (e.g., from global magnetic fields) may affect even widely separated detectors.National Science Foundation (U.S.)United States. National Aeronautics and Space AdministrationCarnegie TrustDavid & Lucile Packard FoundationAlfred P. Sloan Foundatio
31st Annual Meeting and Associated Programs of the Society for Immunotherapy of Cancer (SITC 2016) : part two
Background
The immunological escape of tumors represents one of the main ob- stacles to the treatment of malignancies. The blockade of PD-1 or CTLA-4 receptors represented a milestone in the history of immunotherapy. However, immune checkpoint inhibitors seem to be effective in specific cohorts of patients. It has been proposed that their efficacy relies on the presence of an immunological response. Thus, we hypothesized that disruption of the PD-L1/PD-1 axis would synergize with our oncolytic vaccine platform PeptiCRAd.
Methods
We used murine B16OVA in vivo tumor models and flow cytometry analysis to investigate the immunological background.
Results
First, we found that high-burden B16OVA tumors were refractory to combination immunotherapy. However, with a more aggressive schedule, tumors with a lower burden were more susceptible to the combination of PeptiCRAd and PD-L1 blockade. The therapy signifi- cantly increased the median survival of mice (Fig. 7). Interestingly, the reduced growth of contralaterally injected B16F10 cells sug- gested the presence of a long lasting immunological memory also against non-targeted antigens. Concerning the functional state of tumor infiltrating lymphocytes (TILs), we found that all the immune therapies would enhance the percentage of activated (PD-1pos TIM- 3neg) T lymphocytes and reduce the amount of exhausted (PD-1pos TIM-3pos) cells compared to placebo. As expected, we found that PeptiCRAd monotherapy could increase the number of antigen spe- cific CD8+ T cells compared to other treatments. However, only the combination with PD-L1 blockade could significantly increase the ra- tio between activated and exhausted pentamer positive cells (p= 0.0058), suggesting that by disrupting the PD-1/PD-L1 axis we could decrease the amount of dysfunctional antigen specific T cells. We ob- served that the anatomical location deeply influenced the state of CD4+ and CD8+ T lymphocytes. In fact, TIM-3 expression was in- creased by 2 fold on TILs compared to splenic and lymphoid T cells. In the CD8+ compartment, the expression of PD-1 on the surface seemed to be restricted to the tumor micro-environment, while CD4 + T cells had a high expression of PD-1 also in lymphoid organs. Interestingly, we found that the levels of PD-1 were significantly higher on CD8+ T cells than on CD4+ T cells into the tumor micro- environment (p < 0.0001).
Conclusions
In conclusion, we demonstrated that the efficacy of immune check- point inhibitors might be strongly enhanced by their combination with cancer vaccines. PeptiCRAd was able to increase the number of antigen-specific T cells and PD-L1 blockade prevented their exhaus- tion, resulting in long-lasting immunological memory and increased median survival
Search for gravitational waves from binary black hole inspiral, merger, and ringdown
We present the first modeled search for gravitational waves using the complete binary black-hole gravitational waveform from inspiral through the merger and ringdown for binaries with negligible component spin. We searched approximately 2 years of LIGO data, taken between November 2005 and September 2007, for systems with component masses of 1–99M⊙ [1-99 M circled dot operator] and total masses of 25–100M⊙ [25-100 M circled dot operator]. We did not detect any plausible gravitational-wave signals but we do place upper limits on the merger rate of binary black holes as a function of the component masses in this range. We constrain the rate of mergers for 19M⊙≤m1 [19 M circled dot operator greater than or equal to m subscript 1], m2≤28M⊙ [m subscript 2 greater than or equal to 28 M circled dot operator] binary black-hole systems with negligible spin to be no more than 2.0 Mpc-3 {Mpc superscript -3] Myr-1 [Myr superscript -1] at 90% confidence.National Science Foundation (U.S.)United States. National Aeronautics and Space AdministrationCarnegie TrustLeverhulme TrustDavid & Lucile Packard FoundationResearch CorporationAlfred P. Sloan Foundatio
Gravitational waves from known pulsars: results from the initial detector era
We present the results of searches for gravitational waves from a large selection of pulsars using data from the most recent science runs (S6, VSR2 and VSR4) of the initial generation of interferometric gravitational wave detectors LIGO (Laser Interferometric Gravitational-wave Observatory) and Virgo. We do not see evidence for gravitational wave emission from any of the targeted sources but produce upper limits on the emission amplitude. We highlight the results from seven young pulsars with large spin-down luminosities. We reach within a factor of five of the canonical spin-down limit for all seven of these, whilst for the Crab and Vela pulsars we further surpass their spin-down limits. We present new or updated limits for 172 other pulsars (including both young and millisecond pulsars). Now that the detectors are undergoing major upgrades, and, for completeness, we bring together all of the most up-to-date results from all pulsars searched for during the operations of the first-generation LIGO, Virgo and GEO600 detectors. This gives a total of 195 pulsars including the most recent results described in this paper.David & Lucile Packard FoundationResearch CorporationAlfred P. Sloan Foundatio
Recommended from our members
Application of a Hough search for continuous gravitational waves on data from the fifth LIGO science run
We report on an all-sky search for periodic gravitational waves in the frequency range 50-1000 Hz with the first derivative of frequency in the range -8.9 × 10⁻¹⁰ Hz s⁻¹ to zero in two years of data collected during LIGO's fifth science run. Our results employ a Hough transform technique, introducing a χ² test and analysis of coincidences between the signal levels in years 1 and 2 of observations that offers a significant improvement in the product of strain sensitivity with compute cycles per data sample compared to previously published searches. Since our search yields no surviving candidates, we present results taking the form of frequency dependent, 95% confidence upper limits on the strain amplitude h₀. The most stringent upper limit from year 1 is 1.0 × 10⁻²⁴ in the 158.00-158.25 Hz band. In year 2, the most stringent upper limit is 8.9 × 10⁻²⁵ in the 146.50-146.75 Hz band. This improved detection pipeline, which is computationally efficient by at least two orders of magnitude better than our flagship Einstein@Home search, will be important for 'quick-look' searches in the Advanced LIGO and Virgo detector era