16 research outputs found

    Comparison of Newcastle disease vaccine administered as powder or liquid in relation to the serum antibody response and adverse vaccinal reactions in broilers

    Get PDF
    Liquid spray and aerosol mass vaccination of poultry have several drawbacks, such as uncontrolled deposition of vaccine particles in the respiratory tract and vaccine virus inactivation by formation and evaporation of droplets. These may be addressed by using dry powder vaccines with defined particle size distribution targeting the upper (primary vaccination) or the entire respiratory tract (booster vaccination). Therefore, a coarse Newcastle disease (LZ58 strain) powder vaccine was administered to specified pathogen free (SPF) broiler hens to compare the antibody response and adverse vaccinal reactions with those induced by a coarse liquid spray and a fine liquid aerosol. Groups of 40 broilers each housed in isolators were vaccinated at 4 days of age and intratracheally inoculated with Escherichia coli (strain 506) at 11 days of age. Adverse vaccinal reactions were evaluated by measuring body weight gain and mortality between 4 and 11 days of age and between 11 and 18 days of age, and by recording colibacillosis lesions at 18 days of age. The antibody serum response was measured at 18 days of age by the haemagglutination inhibition test. Despite the relative low initial vaccine virus loss and narrow particle size distribution of the powder vaccines in comparison with their liquid counter parts, no significant differences (P > 0.05) regarding adverse vaccinal reactions and antibody response were observed between broilers vaccinated with the powder vaccines or with their liquid counterparts

    Detection of egg yolk antibodies reflecting Salmonella enteritidis infections using a surface plasmon resonance biosensor

    No full text
    A surface plasmon resonance (SPR) biosensor assay was developed on the basis of a lipopolysaccharide antigen of Salmonella enterica serovar enteritidis (S. enterica serovar enteritidis) to detect egg yolk antibodies against S. enterica serovar enteritidis. This biosensor assay was compared to two commercial ELISA kits based on LPS antigen and flagellar antigen. A number of 163 egg yolk and combined egg white and yolk samples from chickens experimentally infected with S. enterica serovar enteritidis and 90 egg yolk and combined egg white and yolk samples from uninfected chickens were analyzed. Receiver operating characteristic analysis of the data calculated a diagnostic sensitivity of 82% and a diagnostic specificity of 100%. The within-day coefficient of variation of a positive internal-control egg yolk was 1%. The SPR biosensor assay was able to detect antibodies in a significantly higher percentage of known positive samples than the commercial ELISA's. The anticipated use of the SPR biosensor assay is to determine the S. enterica serovar enteritidis serostatus of non-vaccinated layer hen
    corecore