8,495 research outputs found

    Automated clinical system for chromosome analysis

    Get PDF
    An automatic chromosome analysis system is provided wherein a suitably prepared slide with chromosome spreads thereon is placed on the stage of an automated microscope. The automated microscope stage is computer operated to move the slide to enable detection of chromosome spreads on the slide. The X and Y location of each chromosome spread that is detected is stored. The computer measures the chromosomes in a spread, classifies them by group or by type and also prepares a digital karyotype image. The computer system can also prepare a patient report summarizing the result of the analysis and listing suspected abnormalities

    A reliable Pade analytical continuation method based on a high accuracy symbolic computation algorithm

    Full text link
    We critique a Pade analytic continuation method whereby a rational polynomial function is fit to a set of input points by means of a single matrix inversion. This procedure is accomplished to an extremely high accuracy using a novel symbolic computation algorithm. As an example of this method in action we apply it to the problem of determining the spectral function of a one-particle thermal Green's function known only at a finite number of Matsubara frequencies with two example self energies drawn from the T-matrix theory of the Hubbard model. We present a systematic analysis of the effects of error in the input points on the analytic continuation, and this leads us to propose a procedure to test quantitatively the reliability of the resulting continuation, thus eliminating the black magic label frequently attached to this procedure.Comment: 11 pages, 8 eps figs, revtex format; revised version includes reference to anonymous ftp site containing example codes (MapleVr5.1 worksheets) displaying the implementation of the algorithm, including the padematinv.m library packag

    Modelling microelectrode biosensors : free-flow calibration can substantially underestimate tissue concentrations

    Get PDF
    Microelectrode amperometric biosensors are widely used to measure concentrations of analytes in solution and tissue including acetylcholine, adenosine, glucose and glutamate. A great deal of experimental and modelling effort has been directed at quantifying the response of the biosensors themselves; however, the influence that the macroscopic tissue environment has on biosensor response has not been subjected to the same level of scrutiny. Here we identify an important issue in the way microelectrode biosensors are calibrated that is likely to have led to underestimations of analyte tissue concentrations. Concentration in tissue is typically determined by comparing the biosensor signal to that measured in free-flow calibration conditions. In a free-flow environment the concentration of the analyte at the outer surface of the biosensor can be considered constant. However, in tissue the analyte reaches the biosensor surface by diffusion through the extracellular space. Because the enzymes in the biosensor break down the analyte, a density gradient is set up resulting in a significantly lower concentration of analyte near the biosensor surface. This effect is compounded by the diminished volume fraction (porosity) and reduction in the diffusion coefficient due to obstructions (tortuosity) in tissue. We demonstrate this effect through modelling and experimentally verify our predictions in diffusive environments

    Using flow gauges to determine leaf specific conductance in hybrid poplars under mesic and xeric conditions

    Get PDF
    Non-Peer ReviewedA study was conducted using sap flow gauges to determine leaf specific conductance (LSC) in hybrid poplars in an environmentally-controlled greenhouse at Swift Current, Saskatchewan. Sap flow rates were compared between CanAm and Walker poplar clones using stem flow gauges. The primary objectives were to verify differences in LSC observed between the clones under moist field conditions in a previous study and to compare the responses in sap flow and LSC within these trees as imposed soil conditions changed from moist to dry. Walker poplars appear to be well-suited to mesic sites, and, under ample soil moisture, perform better than CanAms. However, they are susceptible to mid-season terminal shoot dieback, while CanAm poplars do not seem to be as susceptible. We suspect that this is primarily attributable to a greater LSC of CanAm poplars and possibly achieving better stomatal responses during periods of extended vapor pressure deficits. The gauges were mounted near the base of each tree. Following gauge installation, the trees were watered to field capacity. No additional water was added during the course of the test. Sap flow, leaf water potentials and tree conditions were monitored for 17 days as the soil conditions evolved from moist to dry. Results indicate that the CanAms displayed a greater LSC under moist as well as dry conditions compared to the Walkers. Throughout the testing period, CanAm mid-day leaf water potentials were slightly more negative than for the Walker poplars. Although CanAm poplars appear to be less water efficient than Walkers, they are better able to function and survive during periods of extended vapour pressure deficits

    Transmission Electron Study of Heteroepitaxial Growth in the BiSrCaCuO System

    Full text link
    Films of Bi2\rm _2Sr2\rm _2CaCu2\rm _2O8\rm _8 and Bi2\rm _2Sr2\rm _2CuO6\rm _6 have been grown using Atomic-Layer-by-Layer Molecular Beam Epitaxy (ALL-MBE) on lattice-matched substrates. These materials have been combined with layers of closely-related metastable compounds like Bi2\rm _2Sr2\rm _2Ca7\rm _7Cu8\rm _8O20\rm _{20} (2278) and rare-earth-doped compounds like Bi2\rm _2Sr2\rm _2Dyx\rm _xCa1x\rm _{1-x}Cu2\rm _2O8\rm _8 (Dy:2212) to form heterostructures with unique superconducting properties, including superconductor/insulator multilayers and tunnel junctions. Transmission electron microscopy (TEM) has been used to study the morphology and microstructure of these heterostructures. These TEM studies shed light on the physical properties of the films, and give insight into the growth mode of highly anisotropic solids like Bi2\rm _2Sr2\rm _2CaCu2\rm _2O8\rm _8.Comment: 17 pages, submitted to J. Materials Research. Email to [email protected] if you want to receive copies of the figure
    corecore