2,471 research outputs found

    Imaging Subtle Microstructural Variations in Ceramics with Precision Ultrasonic Velocity and Attenuation Measurements

    Get PDF
    There is an international research effort to incorporate ceramic components into hot sections of heat engines. A major portion of this effort is directed towards the understanding and control of ceramic processing so that the strength of ceramics may be optimized. To date, the strength of sintered ceramics (e.g., SiC) is well below, by about two orders of magnitude, the theoretical strength [1,4]. This discrepancy is understood to be due to the presence of voids, inclusions, agglomerates, and anomalously large grains [4]. These defects, causing premature failure, are introduced or formed during the ceramic manufacturing process. Considerable work has already been done to remove these strength reducing material variations. This has resulted in a steady increase in the fracture strength of ceramics; however, the rate of this increase has slowed. Adding to the problem is the fact that the fracture strength of identically produced experimental samples varies as much as 35 percent [2]. As a result of the loss of momentum toward higher strengths, researchers are turning to ceramic- ceramic fiber composites. These composites show promise of increasing the fracture strength of ceramic materials even further. It is likely that the same material strength variations will be present, at least locally in the matrix, in ceramic composites

    Magnetic support of the optical emission line filaments in NGC 1275

    Full text link
    The giant elliptical galaxy NGC 1275, at the centre of the Perseus cluster, is surrounded by a well-known giant nebulosity of emission-line filaments, which are plausibly about >10^8 yr old. The filaments are dragged out from the centre of the galaxy by the radio bubbles rising buoyantly in the hot intracluster gas before later falling back. They act as dramatic markers of the feedback process by which energy is transferred from the central massive black hole to the surrounding gas. The mechanism by which the filaments are stabilized against tidal shear and dissipation into the surrounding 4x10^7 K gas has been unclear. Here we report new observations that resolve thread-like structures in the filaments. Some threads extend over 6 kpc, yet are only 70 pc wide. We conclude that magnetic fields in the threads, in pressure balance with the surrounding gas, stabilize the filaments, so allowing a large mass of cold gas to accumulate and delay star formation.Comment: Published in Nature, includes supplementary information, high resolution images available at http://www-xray.ast.cam.ac.uk/papers/ngc1275

    Global anomalies on Lorentzian space-times

    Get PDF
    We formulate an algebraic criterion for the presence of global anomalies on globally hyperbolic space-times in the framework of locally covariant field theory. We discuss some consequences and check that it reproduces the well-known global SU(2) anomaly in four space-time dimensions

    A novel malaria vaccine candidate antigen expressed in Tetrahymena thermophila

    Get PDF
    Development of effective malaria vaccines is hampered by the problem of producing correctly folded Plasmodium proteins for use as vaccine components. We have investigated the use of a novel ciliate expression system, Tetrahymena thermophila, as a P. falciparum vaccine antigen platform. A synthetic vaccine antigen composed of N-terminal and C-terminal regions of merozoite surface protein-1 (MSP-1) was expressed in Tetrahymena thermophila. The recombinant antigen was secreted into the culture medium and purified by monoclonal antibody (mAb) affinity chromatography. The vaccine was immunogenic in MF1 mice, eliciting high antibody titers against both N- and C-terminal components. Sera from immunized animals reacted strongly with P. falciparum parasites from three antigenically different strains by immunofluorescence assays, confirming that the antibodies produced are able to recognize parasite antigens in their native form. Epitope mapping of serum reactivity with a peptide library derived from all three MSP-1 Block 2 serotypes confirmed that the MSP-1 Block 2 hybrid component of the vaccine had effectively targeted all three serotypes of this polymorphic region of MSP-1. This study has successfully demonstrated the use of Tetrahymena thermophila as a recombinant protein expression platform for the production of malaria vaccine antigens

    Increasing condom use in heterosexual men: development of a theory-based interactive digital intervention

    Get PDF
    Increasing condom use to prevent sexually transmitted infections is a key public health goal. Interventions are more likely to be effective if they are theory- and evidence-based. The Behaviour Change Wheel (BCW) provides a framework for intervention development. To provide an example of how the BCW was used to develop an intervention to increase condom use in heterosexual men (the MenSS website), the steps of the BCW intervention development process were followed, incorporating evidence from the research literature and views of experts and the target population. Capability (e.g. knowledge) and motivation (e.g. beliefs about pleasure) were identified as important targets of the intervention. We devised ways to address each intervention target, including selecting interactive features and behaviour change techniques. The BCW provides a useful framework for integrating sources of evidence to inform intervention content and deciding which influences on behaviour to target

    Dispersing the Mists: An Experimental History of Medicine Study into the Quality of Volatile Inhalations

    Get PDF
    This document is the Accepted Manuscript version. The final publication is available from Mary Ann Liebert, Inc. Publishers at https://doi.org/10.1089/jamp.2016.1357.Background: Dr. Nelson's Improved Inhaler was first marketed with an advertisement in The Lancet in 1865. Revolutionary at the time for its ease of use and patient-friendliness, the inhaler is still in use for self-treatment by many all over the world. On the occasion of its 150th anniversary, this study reports an experimental historical medicine approach to identify evidence for the quality of vapor inhalers. Methods: Through accessing reviews of the device's use by the contemporary medical establishment, it was established that Dr. Nelson's Inhaler enjoyed a reputation of quality and efficacy among reputable physicians generating empirical evidence of clinical performance. There was a general absence of product performance tests during this period. Therefore, modern inhalation performance testing was applied to test the aerosol delivery performance for Friars' Balsam, and its key chemical constituent, benzoic acid (BA). Results: A respirable dose of 59.9 ± 9.0 μg of BA was aerosolized in a 10 minutes period from a dose of 3.3 mL Friars' Balsam (equivalent to 35.1 ± 0.2 mg of BA) in 375 mL of steaming water using the glass twin stage impinger at a flow rate of 60 L·min−1. The respirable dose from a standardized aqueous BA inhalation formulation increased from 115.9 ± 10.6 to 200.2 ± 19.9 μg by increasing the simulated inhalation period from 5 to 10 minutes. When tested with a simulated inhalation maneuver (500 mL tidal volume, 13 minutes−1 respiration rate, 1:2 inspiratory:expiratory ratio) a respirable dose of 112.8 ± 40.3 μg was produced. Conclusions: This work has highlighted the potential for aerosol drug delivery using steam inhalers that are popular with patients. Physicians should therefore be aware of the potential for lung dosing with irritants when patients self-medicate using the Nelson Inhaler with vaporizing formulations such as Friars' Balsam.Peer reviewedFinal Accepted Versio

    A Novel Ultrasonic Method for Accurate Characterization of Microstructural Gradients in Monolithic and Composite Tubular Structures

    Get PDF
    Prior studies have shown that ultrasonic velocity/time-of-flight imaging that uses back surface echo reflections to gauge volumetric material quality is well suited (perhaps more so than is the commonlyused peak amplitude c-scanning) for quantitative characterization of microstructural gradients. Such gradients include those due to pore fraction, density, fiber fraction, and chemical composition variations [11–15]. Variations in these microstructural factors can affect the uniformity of physical performance (including mechanical [stiffness, strength], thermal [conductivity], and electrical [conductivity, superconducting transition temperature], etc. performance) of monolithic and composite [1,3,6,12]. A weakness of conventional ultrasonic velocity/time-of-flight imaging (as well as to a lesser extent ultrasonic peak amplitude c-scanning where back surface echoes are gated [17] is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this type of imaging’s usefulness in practical applications. The effect of thickness is easily observed from the equation for pulse-echo waveform time-of-flight (2τ) between the first front surface echo (FS) and the first back surface echo (B1), or between two successive back surface echoes where: 2τ=(2d)V (1) where d is the sample thickness and V is the velocity of ultrasound in the material. Interpretation of the time-of-flight image is difficult as thickness variation effects can mask or overemphasize the true microstructural variation portrayed in the image of a part containing thickness variations. Thickness effects on time-of-flight can also be interpreted by rearranging equation (1) to calculate velocity: V=(2d)2τ (2) such that velocity is inversely proportional to time-of-flight. Velocity and time-of-flight maps will be affected similarly (although inversely in terms of magnitude) by thickness variations, and velocity maps are used in this investigation to indicate time-of-flight variations.</p
    • …
    corecore