726 research outputs found
Two calculation procedures for the determination of composition and mass thickness of thin samples by x-ray spectrometry
Two procedures are described for calculating the composition and mass thickness of thin samples from measured x-ray intensities. One procedure is suitable for use with a programmable hand calculator but gives correct results only for very thin samples. The other procedure utilizes the NRLXRF program and produces correct results for thin and thick films
Ertrag und Qualität von Winterweizengenotypen unter integrierten und ökologischen Anbaubedingungen
An annually identical assortment of each of 32 winter wheat varieties and lines bred
under conventional conditions was tested between 2004 and 2007 both in a
conventionally and in an organically managed environment. Previously the assortment
had been evaluated with respect to yield and indirect parameters of baking quality.
The objective was to obtain evidence for a targeted selection of lines for their later use
as bread varieties in organic farming. It was discovered that for a successful selection
of lines for the subsequent cultivation under organic conditions especially the
evaluation of yield must be conducted strictly under the same conditions
О подборе материала профессиональной направленности на занятиях по немецкому языку в группах факультета искусств
Цель статьи показать ряд методических приемов профессиональной направленности для проведения
занятий по немецкому языку в группах факультета искусств
Exact Calculation of the Vortex-Antivortex Interaction Energy in the Anisotropic 3D XY-model
We have developed an exact method to calculate the vortex-antivortex
interaction energy in the anisotropic 3D-XY model. For this calculation, dual
transformation which is already known for the 2D XY-model was extended. We
found an explicit form of this interaction energy as a function of the
anisotropic ratio and the separation between the vortex and antivortex
located on the same layer. The form of interaction energy is at the
small limi t but is proportional to at the opposite limit. This form of
interaction energ y is consistent with the upper bound calculation using the
variational method by Cataudella and Minnhagen.Comment: REVTeX 12 pages, In print for publication in Phys. Rev.
Risk factors for nosocomial pneumonia comparing adult critical-care populations
The purpose of the study was to examine risk factors for nosocomial pneumonia in the surgical and medical/respiratory intensive care unit (ICU) populations. In a public teaching hospital, all cases of nosocomial pneumonia in the surgical and medical/respiratory ICUs (n = 20, respectively) were identified by prospective surveillance during a 5-yr period from 1987-1991. Each group of ICU cases was compared with 40 ICU control patients who did not acquire pneumonia, and analyzed for 25 potential risk factors. Surgical ICU patients were found to have consistently higher rates of nosocomial pneumonia than medical ICU patients (RR = 2.2). The strongest predictor for nosocomial pneumonia in both the surgical and medical/respiratory ICU groups was found to be prolonged mechanical ventilation (> 1 d) resulting in a 12-fold increase in risk over nonventilated patients. APACHE III score was found to be predictive of nosocomial pneumonia in the surgical ICU population, but not in the medical/respiratory ICU population. We conclude that certain groups deserve special attention for infection control intervention. Surgical ICU patients with high APACHE scores and receiving prolonged mechanical ventilation may be at the greatest risk of acquiring nosocomial pneumonia of all hospitalized patients
Rapid Colorimetric Detection of Pseudomonas aeruginosa in Clinical Isolates Using a Magnetic Nanoparticle Biosensor
A rapid, sensitive, and specific colorimetric biosensor based on the use of magnetic nanoparticles (MNPs) was designed for the detection of Pseudomonas aeruginosa in clinical samples. The biosensing platform was based on the measurement of P. aeruginosa proteolytic activity using a specific protease substrate. At the N-terminus, this substrate was covalently bound to MNPs and was linked to a gold sensor surface via cystine at the C-terminus of the substrates. The golden sensor appears black to naked eyes because of the coverage of the MNPs. However, upon proteolysis, the cleaved peptide-MNP moieties will be attracted by an external magnet, revealing the golden color of the sensor surface, which can be observed by the naked eye. In vitro, the biosensor was able to detect specifically and quantitatively the presence of P. aeruginosa with a detection limit of 102 cfu/mL in less than 1 min. The colorimetric biosensor was used to test its ability to detect in situ P. aeruginosa in clinical isolates from patients. This biochip is anticipated to be useful as a rapid point-of-care device for the diagnosis of P. aeruginosa-related infections
Optical frequency measurement of the 1S-3S two-photon transition in hydrogen
This article reports the first optical frequency measurement of the
transition in hydrogen. The excitation of this
transition occurs at a wavelength of 205 nm which is obtained with two
frequency doubling stages of a titanium sapphire laser at 820 nm. Its frequency
is measured with an optical frequency comb. The second-order Doppler effect is
evaluated from the observation of the motional Stark effect due to a transverse
magnetic field perpendicular to the atomic beam. The measured value of the
frequency splitting is with a relative uncertainty of
. After the measurement of the
frequency, this result is the most precise of the optical frequencies in
hydrogen
and Oxygen Stoichiometry: Structure, Resistivity, Fermi Surface Topology and Normal State Properties
(2212) single crystal samples
were studied using transmission electron microscopy (TEM), plane
() and axis () resistivity, and high resolution
angle-resolved ultraviolet photoemission spectroscopy (ARUPS). TEM reveals that
the modulation in the axis for doped 2212 is dominantly
of type that is not sensitive to the oxygen content of the system, and the
system clearly shows a structure of orthorhombic symmetry. Oxygen annealed
samples exhibit a much lower axis resistivity and a resistivity minimum at
K. He-annealed samples exhibit a much higher axis resistivity and
behavior below 300K. The Fermi surface (FS) of oxygen annealed
2212 mapped out by ARUPS has a pocket in the FS around the
point and exhibits orthorhombic symmetry. There are flat, parallel sections of
the FS, about 60\% of the maximum possible along , and about 30\%
along . The wavevectors connecting the flat sections are about
along , and about along , rather than . The symmetry of the near-Fermi-energy dispersing
states in the normal state changes between oxygen-annealed and He-annealed
samples.Comment: APS_REVTEX 3.0, 49 pages, including 11 figures, available upon
request. Submitted to Phys. Rev. B
- …