47 research outputs found
Tight-binding parameters for charge transfer along DNA
We systematically examine all the tight-binding parameters pertinent to
charge transfer along DNA. The molecular structure of the four DNA bases
(adenine, thymine, cytosine, and guanine) is investigated by using the linear
combination of atomic orbitals method with a recently introduced
parametrization. The HOMO and LUMO wavefunctions and energies of DNA bases are
discussed and then used for calculating the corresponding wavefunctions of the
two B-DNA base-pairs (adenine-thymine and guanine-cytosine). The obtained HOMO
and LUMO energies of the bases are in good agreement with available
experimental values. Our results are then used for estimating the complete set
of charge transfer parameters between neighboring bases and also between
successive base-pairs, considering all possible combinations between them, for
both electrons and holes. The calculated microscopic quantities can be used in
mesoscopic theoretical models of electron or hole transfer along the DNA double
helix, as they provide the necessary parameters for a tight-binding
phenomenological description based on the molecular overlap. We find that
usually the hopping parameters for holes are higher in magnitude compared to
the ones for electrons, which probably indicates that hole transport along DNA
is more favorable than electron transport. Our findings are also compared with
existing calculations from first principles.Comment: 15 pages, 3 figures, 7 table
Fitting the integrated Spectral Energy Distributions of Galaxies
Fitting the spectral energy distributions (SEDs) of galaxies is an almost
universally used technique that has matured significantly in the last decade.
Model predictions and fitting procedures have improved significantly over this
time, attempting to keep up with the vastly increased volume and quality of
available data. We review here the field of SED fitting, describing the
modelling of ultraviolet to infrared galaxy SEDs, the creation of
multiwavelength data sets, and the methods used to fit model SEDs to observed
galaxy data sets. We touch upon the achievements and challenges in the major
ingredients of SED fitting, with a special emphasis on describing the interplay
between the quality of the available data, the quality of the available models,
and the best fitting technique to use in order to obtain a realistic
measurement as well as realistic uncertainties. We conclude that SED fitting
can be used effectively to derive a range of physical properties of galaxies,
such as redshift, stellar masses, star formation rates, dust masses, and
metallicities, with care taken not to over-interpret the available data. Yet
there still exist many issues such as estimating the age of the oldest stars in
a galaxy, finer details ofdust properties and dust-star geometry, and the
influences of poorly understood, luminous stellar types and phases. The
challenge for the coming years will be to improve both the models and the
observational data sets to resolve these uncertainties. The present review will
be made available on an interactive, moderated web page (sedfitting.org), where
the community can access and change the text. The intention is to expand the
text and keep it up to date over the coming years.Comment: 54 pages, 26 figures, Accepted for publication in Astrophysics &
Space Scienc
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Liquid xenon time projection chambers are promising detectors to search for
neutrinoless double beta decay (0), due to their response
uniformity, monolithic sensitive volume, scalability to large target masses,
and suitability for extremely low background operations. The nEXO collaboration
has designed a tonne-scale time projection chamber that aims to search for
0 of \ce{^{136}Xe} with projected half-life sensitivity of
~yr. To reach this sensitivity, the design goal for nEXO is
1\% energy resolution at the decay -value (~keV).
Reaching this resolution requires the efficient collection of both the
ionization and scintillation produced in the detector. The nEXO design employs
Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm
scintillation light of liquid xenon. This paper reports on the characterization
of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3
SiPMs specifically designed for nEXO, as well as new measurements on new test
samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters
(MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct
crosstalk, correlated avalanches and photon detection efficiency were measured
as a function of the applied over voltage and wavelength at liquid xenon
temperature (163~K). The results from this study are used to provide updated
estimates of the achievable energy resolution at the decay -value for the
nEXO design
Effects of sleep deprivation on neural functioning: an integrative review
Sleep deprivation has a broad variety of effects on human performance and neural functioning that manifest themselves at different levels of description. On a macroscopic level, sleep deprivation mainly affects executive functions, especially in novel tasks. Macroscopic and mesoscopic effects of sleep deprivation on brain activity include reduced cortical responsiveness to incoming stimuli, reflecting reduced attention. On a microscopic level, sleep deprivation is associated with increased levels of adenosine, a neuromodulator that has a general inhibitory effect on neural activity. The inhibition of cholinergic nuclei appears particularly relevant, as the associated decrease in cortical acetylcholine seems to cause effects of sleep deprivation on macroscopic brain activity. In general, however, the relationships between the neural effects of sleep deprivation across observation scales are poorly understood and uncovering these relationships should be a primary target in future research