50,157 research outputs found

    EXIST: Mission Design Concept and Technology Program

    Get PDF
    The Energetic X-ray Imaging Survey Telescope (EXIST) is a proposed very large area coded aperture telescope array, incorporating 8m^2 of pixellated Cd-Zn-Te (CZT) detectors, to conduct a full-sky imaging and temporal hard x-ray (10-600 keV) survey each 95min orbit. With a sensitivity (5sigma, 1yr) of ~0.05mCrab (10-150 keV), it will extend the ROSAT soft x-ray (0.5-2.5keV) and proposed ROSITA medium x-ray (2-10 keV) surveys into the hard x-ray band and enable identification and study of sources ~10-20X fainter than with the ~15-100keV survey planned for the upcoming Swift mission. At ~100-600 keV, the ~1mCrab sensitivity is 300X that achieved in the only previous (HEAO-A4, non-imaging) all-sky survey. EXIST will address a broad range of key science objectives: from obscured AGN and surveys for black holes on all scales, which constrain the accretion history of the universe, to the highest sensitivity and resolution studies of gamma-ray bursts it will conduct as the Next Generation Gamma-Ray Burst mission. We summarize the science objectives and mission drivers, and the results of a mission design study for implementation as a free flyer mission, with Delta IV launch. Key issues affecting the telescope and detector design are discussed, and a summary of some of the current design concepts being studied in support of EXIST is presented for the wide-field but high resolution coded aperture imaging and very large area array of imaging CZT detectors. Overall mission design is summarized, and technology development needs and a development program are outlined which would enable the launch of EXIST by the end of the decade, as recommended by the NAS/NRC Decadal Survey.Comment: 14 pages, 8 figures, 2 tables. PDF file only. Presented at SPIE (Aug. 2002) and to appear in Proc. SPIE, vol. 485

    Spectral Representation Theory for Dielectric Behavior of Nonspherical Cell Suspensions

    Full text link
    Recent experiments revealed that the dielectric dispersion spectrum of fission yeast cells in a suspension was mainly composed of two sub-dispersions. The low-frequency sub-dispersion depended on the cell length, while the high-frequency one was independent of it. The cell shape effect was simulated by an ellipsoidal cell model but the comparison between theory and experiment was far from being satisfactory. Prompted by the discrepancy, we proposed the use of spectral representation to analyze more realistic cell models. We adopted a shell-spheroidal model to analyze the effects of the cell membrane. It is found that the dielectric property of the cell membrane has only a minor effect on the dispersion magnitude ratio and the characteristic frequency ratio. We further included the effect of rotation of dipole induced by an external electric field, and solved the dipole-rotation spheroidal model in the spectral representation. Good agreement between theory and experiment has been obtained.Comment: 19 pages, 5 eps figure

    Nonlinear dynamic analysis of shells of revolution by matrix displacement method

    Get PDF
    Nonlinear dynamic analysis of shells of revolution by matrix displacement metho

    Detector and Telescope Development for ProtoEXIST and Fine Beam Measurements of Spectral Response of CZT Detectors

    Get PDF
    We outline our plan to develop ProtoEXIST, a balloon-borne prototype experiment for the Energetic X-ray Imaging Survey Telescope (EXIST) for the Black Hole Finder Probe. EXIST will consist of multiple wide-field hard X-ray coded-aperture telescopes. The current design of the EXIST mission employs two types of telescope systems: high energy telescopes (HETs) using CZT detectors, and low energy telescopes (LETs) using Si detectors. With ProtoEXIST, we will develop and demonstrate the technologies required for the EXIST HETs. As part of our development efforts, we also present recent laboratory measurements of the spectral response and efficiency variation of imaging CZT detectors on a fine scale (~0.5 mm). The preliminary results confirm the need for multi-pixel readouts and small inter-pixel gaps to achieve uniform spectral response and high detection efficiency across detectors.Comment: 9 pages, 12 figures, 1 table, appears in SPIE 2005 proceedings (5898: UV, X-ray, and Gamma-ray Space Instrumentation for Astronomy XIV

    Gait Verification using Knee Acceleration Signals

    Get PDF
    A novel gait recognition method for biometric applications is proposed. The approach has the following distinct features. First, gait patterns are determined via knee acceleration signals, circumventing difficulties associated with conventional vision-based gait recognition methods. Second, an automatic procedure to extract gait features from acceleration signals is developed that employs a multiple-template classification method. Consequently, the proposed approach can adjust the sensitivity and specificity of the gait recognition system with great flexibility. Experimental results from 35 subjects demonstrate the potential of the approach for successful recognition. By setting sensitivity to be 0.95 and 0.90, the resulting specificity ranges from 1 to 0.783 and 1.00 to 0.945, respectively
    corecore