4,256 research outputs found

    Design and performance of a 39cm balloon-borne telescope

    Get PDF
    A system for stabilizing a balloon-borne telescope using a star sensor device is described. Guide stars from minus four to plus four magnitude can be used and the sensor may be offset with respect to the telescope by as much as plus or minus five degrees in elevation and cross elevation to enable parts of the sky containing no suitable guide stars to be viewed. Acquisition of the guide star and setting of the offset coordinates is carried out by ground command and both may be changed in flight. The main design parameters of the equipment are summarized. Block diagrams and circuit diagrams of the star tracker are provided

    Electron Interactions and Transport Between Coupled Quantum Hall Edges

    Full text link
    We examine the effects of electron-electron interactions on transport between edge states in a multilayer integer quantum Hall system. The edge states of such a system, coupled by interlayer tunneling, form a two-dimensional, chiral metal at the sample surface. We calculate the temperature-dependent conductivity and the amplitude of conductance fluctuations in this chiral metal, treating Coulomb interactions and disorder exactly in the weak-tunneling limit. We find that the conductivity increases with increasing temperature, as observed in recent experiments, and we show that the correlation length characterising conductance fluctuations varies inversely with temperature.Comment: 4 pages, 2 figures, typos corrected, Ref. 17 added, minor changes made for publicatio

    Nuclear Magnetic Resonance and Hyperfine Structure

    Get PDF
    Contains reports on three research projects

    Laboratory Information Management System Chain of Custody: Reliability and Security

    Get PDF
    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare

    Design, fabrication, and delivery of a charge injection device as a stellar tracking device

    Get PDF
    Six 128 x 128 CID imagers fabricated on bulk silicon and with thin polysilicon upper-level electrodes were tested in a star tracking mode. Noise and spectral response were measured as a function of temperature over the range of +25 C to -40 C. Noise at 0 C and below was less than 40 rms carriers/pixel for all devices at an effective noise bandwidth of 150 Hz. Quantum yield for all devices averaged 40% from 0.4 to 1.0 microns with no measurable temperature dependence. Extrapolating from these performance parameters to those of a large (400 x 400) array and accounting for design and processing improvements, indicates that the larger array would show a further improvement in noise performance -- on the order of 25 carriers. A preliminary evaluation of the projected performance of the 400 x 400 array and a representative set of star sensor requirements indicates that the CID has excellent potential as a stellar tracking device

    Nuclear Magnetic Resonance and Hyperfine Structure

    Get PDF
    Contains reports on three research projects

    Nuclear Magnetic Resonance and Hyperfine Structure

    Get PDF
    Contains reports on four research projects

    Nuclear Magnetic Resonance and Hyperfine Structure

    Get PDF
    Contains reports on six research projects

    Transport between edge states in multilayer integer quantum Hall systems: exact treatment of Coulomb interactions and disorder

    Full text link
    A set of stacked two-dimensional electron systems in a perpendicular magnetic field exhibits a three-dimensional version of the quantum Hall effect if interlayer tunneling is not too strong. When such a sample is in a quantum Hall plateau, the edge states of each layer combine to form a chiral metal at the sample surface. We study the interplay of interactions and disorder in transport properties of the chiral metal, in the regime of weak interlayer tunneling. Our starting point is a system without interlayer tunneling, in which the only excitations are harmonic collective modes: surface magnetoplasmons. Using bosonization and working perturbatively in the interlayer tunneling amplitude, we express transport properties in terms of the spectrum for these collective modes, treating electron-electron interactions and impurity scattering exactly. We calculte the conductivity as a function of temperature, finding that it increases with increasing temperature as observed in recent experiments. We also calculate the autocorrelation function of mesoscopic conductance fluctuations induced by changes in a magnetic field component perpendicular to the sample surface, and its dependence on temperature. We show that conductance fluctuations are characterised by a dephasing length that varies inversely with temperature.Comment: 13 pages, 10 figures, minor changes made for publicatio

    Development of diagnostic algorithm for Cushing’s syndrome: a tertiary centre experience

    Get PDF
    Purpose: No consensus exists as the gold standard for Cushing’s Syndrome (CS) screening. This study aimed to evaluate the diagnostic accuracy and utility of late-night salivary cortisol (LNSC) and cortisone (LNSE), overnight dexamethasone suppression test (ODST), and urinary free cortisol (UFC) in developing a screening algorithm for CS. Methods: A retrospective, single-centre analysis on 93 adult patients referred to the Oxford Centre for Diabetes, Endocrinology, and Metabolism for CS evaluation (2017–2022). Data were analysed using binomial logistic regression and area under the receiver-operating curve (AUROC). Results: Fifty-three patients were diagnosed with CS. LNSC (sensitivity 87.5%, specificity 64.9%, AUC 0.76), LNSE (sensitivity 72.4%, specificity 85.7%, AUC 0.79), and ODST (sensitivity 94.7%, specificity 52.1%; AUC 0.74) demonstrated comparable effectiveness for CS diagnosis. Their combined application increased diagnostic accuracy (AUC 0.91). UFC was not statistically significant. Pre-test clinical symptom inclusion improved screening test performance (AUC LNSC: 0.83; LNSE: 0.84; ODST: 0.82). For CD diagnosis, LNSE + LNSC (AUC 0.95) outperformed ODST. Combining these with ACTH levels < 12.6 pmol/L perfectly distinguished MACS (AUC 1.00). ODST (AUC 0.76) exhibited superior performance (sensitivity 100.0%, specificity 52.2%) in MACS detection. Conclusions: LNSC, LNSE, and ODST are robust tools for CS screening, with their combined use offering the highest diagnostic precision. LNSE, especially when used with LNSC, is highly effective for CD diagnosis, exceeding ODST accuracy. ODST is preferable for MACS identification. Integrating ACTH levels markedly improves differentiation between CD and MACS. Conversely, UFC shows limited diagnostic utility
    corecore