3,442 research outputs found

    The Photometry of Undersampled Point Spread Functions

    Get PDF
    An undersampled point spread function may interact with the microstructure of a solid-state detector such that the total flux detected can depend sensitively on where the PSF center falls within a pixel. Such intra-pixel sensitivity variations will not be corrected by flat field calibration and may limit the accuracy of stellar photometry conducted with undersampled images, as are typical for Hubble Space Telescope observations. The total flux in a stellar image can vary by up to 0.03 mag in F555W WFC images depending on how it is sampled, for example. For NIC3, these variations are especially strong, up to 0.39 mag, strongly limiting its use for stellar photometry. Intra-pixel sensitivity variations can be corrected for, however, by constructing a well-sampled PSF from a dithered data set. The reconstructed PSF is the convolution of the optical PSF with the pixel response. It can be evaluated at any desired fractional pixel location to generate a table of photometric corrections as a function of relative PSF centroid. A caveat is that the centroid of an undersampled PSF can also be affected by the pixel response function, thus sophisticated centroiding methods, such as cross-correlating the observed PSF with its fully-sampled counterpart, are required to derive the proper photometric correction.Comment: 20 pages, 14 postscript figures, submitted to the PAS

    Infrared analysis of polyethylene wear specimens using attenuated total reflection spectroscopy

    Get PDF
    Attenuated total reflection infrared spectroscopy was used to analyze ultrahigh molecular weight polyethylene wear test specimens. Three different specimens were analyzed. One specimen was gamma irradiated to a dose of 5.0 MRad, another to a dose of 2.5 MRad, and the final specimen was unirradiated. There was no conclusive evidence of chemical changes (i.e., unsaturation or oxidation) in the surface regions of any of the polyethylene samples. Therefore, it was concluded that the gamma irradiation sterilization procedure shoud not alter the boundary lubricating properties of the polyethylene

    Analysis of a thioether lubricant by infrared Fourier microemission spectrophotometry

    Get PDF
    An infrared Fourier microemission spectrophotometer is used to obtain spectra (wavenumber range, 630 to 1230 0.1 cm) from microgram quantities of thioether lubricant samples deposited on aluminum foil. Infrared bands in the spectra are reproducible and could be identified as originating from aromatic species (1,3-disubstituted benzenes). Spectra from all samples (neat and formulated, used and unused) are very similar. Additives (an acid and a phosphinate) present in low concentration (0.10 percent) in the formulated fluid are not detected. This instrument appears to be a viable tool in helping to identify lubricant components separated by liquid chromatography

    Effect of aluminum substitution on the reflectance spectra of hematite

    Get PDF
    Hematite and aluminous hematite were synthesized and the diffuse reflectance spectra were recorded for the region between 0.35 and 1.20 microns. Results show that the near-IR based minimum for the aluminous hematite is shifted longward by about 0.02 microns and is much more shallow. Also, the aluminous specimen is considerably more reflective shortward of approximately 0.55 microns where the ferritic specimen is strongly absorbing. This is noteworthy since the visible slope and the red shoulder are often used in the construction of false color and band ratio images

    Community Radio in Guatemala: A Half-Century of Resistance in the Face of Repression

    Get PDF
    While Guatemalan community radio stations have been legally repressed or “criminalized” since 1996, there is a longer trend of military repression of community radio stations that reaches back to the 1970s. Looking at an extended narrative of repression lends context to the present day fight for policy change in favor of community radio rights; it illustrates a continual exclusion and sustained repression by the state against the institution of Guatemalan community radio and the Maya campesino population

    Characterization of lubricated bearing surfaces operated under high loads

    Get PDF
    The composition and surface profiles of M-50 steel surfaces were measured after operation at high loads in a bearing contact simulator. An ester lubricant (trimethyolpropane triheptanoate) was used with and without various additives. Optical profiles were obtained + or - to 30 depth resolution with a phase-locked interference microscope in 10 micron diameter areas within and outside the wear tracks. Optical constants and surface film thickness were measured in the same areas with an electronic scanning ellipsometer. Film composition was measured with a scanning Auger electron spectrometer. It is concluded that metal oxide formation is accelerated within the wear tracks

    Surface profile changes of scuffed bearing surfaces

    Get PDF
    A phase locked interference microscope capable of resolving depth differences to 30 A and planar displacements of 6000 A was constructed for the examination of the profiles of bearing surfaces without physical contact. This instrument was used to determine surface chemical reactivity by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. Scuffed bearing surfaces reacted much faster than unscuffed ones, but bearing surfaces which had been previously exposed to lubricants containing an organic chloride reacted much more slowly. In a separate series of experiments, a number of stainless steel plates were heated in a nitrogen atmosphere to different temperatures and their reactivity examined later at room temperature. The change of surface contour as a result of the probe reaction followed an Arrhenius type relation with respect to heat treatment temperature. This result could have implications on the scuffing mechanism

    Infrared emission spectrophotometric study of the changes produced by TiN coating of metal surfaces in an operating EHD contact

    Get PDF
    Infrared emission spectra and related measurements were obtained from an operating ball/plate elastohydrodynamic (EHD) sliding contact under a variety of operating conditions. In order to be able to compare the effect of the ball surface, some of the balls were coated with a thin layer of titanium nitride (TiN) by vapor deposition. Polyphenyl ether (5P4E) was used as lubricant and 1 percent of 1,1,2-trichloroethane (TCE) as a surface-probing additive. TiN is chemically inert and its thermal conductivity is lower than that of steel. Therefore, the overall temperatures with TiN coated balls were higher. Nevertheless, no scuffing was observed with the coated balls under conditions giving rise to scuffing with the uncoated balls. Tractions were lower with the TiN coated balls and always when TCE was added to the 5P4E. These findings were found to be inversely related to the degree of polarization of the spectral emission bands. The intensity and the dichrosim of these bands were related to shear rates and inlet conditions of the EHD contact

    Effect of Imperceptible Vibratory Noise Applied to Wrist Skin On Fingertip Touch Evoked Potentials – An EEG Study

    Get PDF
    Random vibration applied to skin can change the sense of touch. Specifically, low amplitude white-noise vibration can improve fingertip touch perception. In fact, fingertip touch sensation can improve even when imperceptible random vibration is applied to other remote upper extremity areas such as wrist, dorsum of the hand, or forearm. As such, vibration can be used to manipulate sensory feedback and improve dexterity, particularly during neurological rehabilitation. Nonetheless, the neurological bases for remote vibration enhanced sensory feedback are yet poorly understood. This study examined how imperceptible random vibration applied to the wrist changes cortical activity for fingertip sensation. We measured somatosensory evoked potentials to assess peak-to-peak response to light touch of the index fingertip with applied wrist vibration versus without. We observed increased peak-to-peak somatosensory evoked potentials with wrist vibration, especially with increased amplitude of the later component for the somatosensory, motor, and premotor cortex with wrist vibration. These findings corroborate an enhanced cortical-level sensory response motivated by vibration. It is possible that the cortical modulation observed here is the result of the establishment of transient networks for improved perception
    corecore