655 research outputs found
Upgrades of beam diagnostics in support of emittance-exchange experiments at the Fermilab A0 photoinjector
The possibility of using electron beam phase space manipulations to support a
free-electron laser accelerator design optimization has motivated our research.
An on-going program demonstrating the exchange of transverse horizontal and
longitudinal emittances at the Fermilab A0 photoinjector has benefited recently
from the upgrade of several of the key diagnostics stations. Accurate
measurements of these properties upstream and downstream of the exchanger
beamline are needed. Improvements in the screen resolution term and reduced
impact of the optical system's depth-of-focus by using YAG:Ce single crystals
normal to the beam direction will be described. The requirement to measure
small energy spreads (<10 keV) in the spectrometer and the exchange process
which resulted in bunch lengths less than 500 fs led to other diagnostics
performance adjustments and upgrades as well. A longitudinal to transverse
exchange example is also reported.Comment: 16 p
Beam instrumentation for the Tevatron Collider
The Tevatron in Collider Run II (2001-present) is operating with six times
more bunches and many times higher beam intensities and luminosities than in
Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and
the never-ending luminosity upgrade campaign. We present the overall picture of
the Tevatron diagnostics development for Run II, outline machine needs for new
instrumentation, present several notable examples that led to Tevatron
performance improvements, and discuss the lessons for future colliders
First observation of the exchange of transverse and longitudinal emittances
An experimental program to demonstrate a novel phase space manipulation in
which the horizontal and longitudinal emittances of a particle beam are
exchanged has been completed at the Fermilab A0 Photoinjector. A new beamline,
consisting of a TM110 deflecting mode cavity flanked by two horizontally
dispersive doglegs has been installed. We report on the first direct
observation of transverse and longitudinal emittance exchange
Synchrotron radiation based beam diagnostics at the Fermilab Tevatron
Synchrotron radiation has been used for many years as a beam diagnostic at
electron accelerators. It is not normally associated with proton accelerators
as the intensity of the radiation is too weak to make detection practical.
However, if one utilizes the radiation originating near the edge of a bending
magnet, or from a short magnet, the rapidly changing magnetic field serves to
enhance the wavelengths shorter than the cutoff wavelength, which for more
recent high energy proton accelerators such as Fermilab's Tevatron, tends to be
visible light. This paper discusses the implementation at the Tevatron of two
devices. A transverse beam profile monitor images the synchrotron radiation
coming from the proton and antiproton beams separately and provides profile
data for each bunch. A second monitor measures the low-level intensity of beam
in the abort gaps which poses a danger to both the accelerator's
superconducting magnets and the silicon detectors of the high energy physics
experiments. Comparisons of measurements from the profile monitor to
measurements from the flying wire profile systems are presented as are a number
of examples of the application of the profile and abort gap intensity
measurements to the modelling of Tevatron beam dynamics
Measurement of the Strong Coupling Constant from Inclusive Jet Production at the Tevatron Collider
We report a measurement of the strong coupling constant, ,
extracted from inclusive jet production in collisions at
1800 GeV. The QCD prediction for the evolution of with
jet transverse energy is tested over the range 40<<450 GeV using
for the renormalization scale. The data show good agreement with QCD in
the region below 250 GeV. In the text we discuss the data-theory comparison in
the region from 250 to 450 GeV. The value of at the mass of the
boson averaged over the range 40<<250 GeV is found to be
. The associated theoretical uncertainties are mainly due to the choice
of renormalization scale (^{+6%}_{-4%}) and input parton distribution
functions (5%).Comment: 7 pages, 3 figures, using RevTeX. Submitted to Physical Review
Letter
Measurement of Rapidity Distribution for High Mass Drell-Yan ee Pairs at CDF
We report on the first measurement of the rapidity distribution dsigma/dy
over nearly the entire kinematic region of rapidity for e^+e^- pairs in the
Z-boson region of 66116 GeV/c^2.
The data sample consists of 108 pb^{-1} of ppbar collisions at \sqrt{s}=1.8 TeV
taken by the Collider Detector at Fermilab during 1992--1995. The total cross
section in the -boson region is measured to be 252 +- 11 pb. The measured
total cross section and d\sigma/dy are compared with quantum chromodynamics
calculations in leading and higher orders.Comment: 7 pages, 3 figures. Submitted to Physical Review Letter
Search for a Fourth-Generation Quark More Massive than the Z0 Boson in ppbar Collisions at sqrt(s) = 1.8 TeV
We present the results of a search for pair production of a fourth-generation
charge -1/3 quark (b') in sqrt(s)=1.8 TeV ppbar collisions using 88 pb^(-1) of
data obtained with the Collider Detector at Fermilab. We assume that both
quarks decay via the flavor-changing neutral current process b' -> bZ and that
the b' mass is greater than m_Z + m_b. We studied the decay mode b'b'bar -> ZZ
b bbar where one Z0 decays into e^+e^- or mu^+ mu^- and the other decays
hadronically, giving a signature of two leptons plus jets. An upper limit on
the cross section of ppbar -> b'b'bar times [BR (b' -> bZ)]^2 is established as
a function of the b' mass. We exclude at 95% confidence level a b' quark with
mass between 100 and 199 GeV/c^2 for BR(b' -> bZ) = 100%.Comment: 12 pages, 2 figures, submitted to Phys. Rev. Letters on 9/12/9
Search for charged Higgs decays of the top quark using hadronic tau decays
We present the result of a search for charged Higgs decays of the top quark,
produced in collisions at 1.8 TeV. When the charged
Higgs is heavy and decays to a tau lepton, which subsequently decays
hadronically, the resulting events have a unique signature: large missing
transverse energy and the low-charged-multiplicity tau. Data collected in the
period 1992-1993 at the Collider Detector at Fermilab, corresponding to
18.70.7~pb, exclude new regions of combined top quark and charged
Higgs mass, in extensions to the standard model with two Higgs doublets.Comment: uuencoded, gzipped tar file of LaTeX and 6 Postscript figures; 11 pp;
submitted to Phys. Rev.
- …