53 research outputs found

    Ninety-day complication rate based on 532 Latarjet procedures in Dutch hospitals with different operation volumes

    Get PDF
    Background: In this study, we aimed to provide insight into the 90-day complication rates following the Latarjet procedure. Data from 2015 were collected from multiple hospitals in the Netherlands, with different volumes of Latarjet procedures. Our second aim was to examine which patient and surgical factors were associated with complications.Methods: We conducted a retrospective chart review of 13 hospitals between 2015 and 2022. Data regarding complications within 90 days of Latarjet procedures were extracted. The effect of sex, age, body mass index (BMI), smoking, previous shoulder operations, fixation material, hospital volume, screw size, and operation time on the complication rate was assessed by multivariable logistic regression analysis.Results: Of the 532 included patients, 58 (10.9%) had complications. The most common complications were material failure (n = 19, 3.6%) and nerve injury (n = 13, 2.4%). The risk of complications was lower for male patients than for female patients (odds ratio, 0.40; 95% confidence interval, 0.21-0.77; P = .006). Age, BMI, smoking, previous shoulder operations, type of fixation material, hospital volume, screw size, and operation time were not associated with complications.Conclusion: The 90-day complication rate after the Latarjet procedure was 10.9% and was higher in female patients than in male patients. Age, BMI, smoking, previous shoulder operations, type of fixation material, hospital volume, screw size, and operation time did not affect complication rates. We advise setting up a national registry to prevent under-reporting of complications.</p

    Interobserver reliability of classification and characterization of proximal humeral fractures: a comparison of two and three-dimensional CT

    Full text link
    Interobserver reliability for the classification of proximal humeral fractures is limited. The aim of this study was to test the null hypothesis that interobserver reliability of the AO classification of proximal humeral fractures, the preferred treatment, and fracture characteristics is the same for two-dimensional (2-D) and three-dimensional (3-D) computed tomography (CT). Members of the Science of Variation Group--fully trained practicing orthopaedic and trauma surgeons from around the world--were randomized to evaluate radiographs and either 2-D CT or 3-D CT images of fifteen proximal humeral fractures via a web-based survey and respond to the following four questions: (1) Is the greater tuberosity displaced? (2) Is the humeral head split? (3) Is the arterial supply compromised? (4) Is the glenohumeral joint dislocated? They also classified the fracture according to the AO system and indicated their preferred treatment of the fracture (operative or nonoperative). Agreement among observers was assessed with use of the multirater kappa (&kappa;) measure. Interobserver reliability of the AO classification, fracture characteristics, and preferred treatment generally ranged from &quot;slight&quot; to &quot;fair.&quot; A few small but statistically significant differences were found. Observers randomized to the 2-D CT group had slightly but significantly better agreement on displacement of the greater tuberosity (&kappa; = 0.35 compared with 0.30, p &lt; 0.001) and on the AO classification (&kappa; = 0.18 compared with 0.17, p = 0.018). A subgroup analysis of the AO classification results revealed that shoulder and elbow surgeons, orthopaedic trauma surgeons, and surgeons in the United States had slightly greater reliability on 2-D CT, whereas surgeons in practice for ten years or less and surgeons from other subspecialties had slightly greater reliability on 3-D CT. Proximal humeral fracture classifications may be helpful conceptually, but they have poor interobserver reliability even when 3-D rather than 2-D CT is utilized. This may contribute to the similarly poor interobserver reliability that was observed for selection of the treatment for proximal humeral fractures. The lack of a reliable classification confounds efforts to compare the outcomes of treatment methods among different clinical trials and reports

    Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    Get PDF
    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tear

    Functional treatment versus plaster for simple elbow dislocations (FuncSiE): a randomized trial

    Get PDF
    Background. Elbow dislocations can be classified as simple or complex. Simple dislocations are characterized by the absence of fractures, while complex dislocations are associated with fractures. After reduction of a simple dislocation, treatment options include immobilization in a static plaster for different periods of time or so-called functional treatment. Functional treatment is characterized by early active motion within the limits of pain with or without the use of a sling or hinged brace. Theoretically, functional treatment should prevent stiffness without introducing increased joint instability. The primary aim of this randomized controlled trial is to compare early functional treatment versus plaster immobilization following simple dislocations of the elbow. Methods/Design. The design of the study will be a multicenter randomized controlled trial of 100 patients who have sustained a simple elbow dislocation. After reduction of the dislocation, patients are randomized between a pressure bandage for 5-7 days and early functional treatment or a plaster in 90 degrees flexion, neutral position for pro-supination for a period of three weeks. In the functional group, treatment is started with early active motion within the limits of pain. Function, pain, and radiographic recovery will be evaluated at regular intervals over the subsequent 12 months. The primary outcome measure is the Quick Disabilities of the Arm, Shoulder, and Hand score. The secondary outcome measures are the Mayo Elbow Performance Index, Oxford elbow score, pain level at both sides, range of motion of the elbow joint at both sides, rate of secondary interventions and complication rates in both groups (secondary dislocation, instability, relaxation), health-related quality of life (Short-Form 36 and EuroQol-5D), radiographic appearance of the elbow joint (degenerative changes and heterotopic ossifications), costs, and cost-effectiveness. Discussion. The successful completion of this trial will provide evidence on the effectiveness of a functional treatment for the management of simple elbow dislocations. Trial Registration. The trial is registered at the Netherlands Trial Register (NTR2025)

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Rotator cuff tear: A detailed update

    Get PDF
    Rotator cuff tear has been a known entity for orthopaedic surgeons for more than two hundred years. Although the exact pathogenesis is controversial, a combination of intrinsic factors proposed by Codman and extrinsic factors theorized by Neer is likely responsible for most rotator cuff tears. Magnetic resonance imaging remains the gold standard for the diagnosis of rotator cuff tears, but the emergence of ultrasound has revolutionized the diagnostic capability. Even though mini-open rotator cuff repair is still commonly performed, and results are comparable to arthroscopic repair, all-arthroscopic repair of rotator cuff tear is now fast becoming a standard care for rotator cuff repair. Appropriate knowledge of pathology and healing pattern of cuff, strong and biological repair techniques, better suture anchors, and gradual rehabilitation of postcuff repair have led to good to excellent outcome after repair. As the healing of degenerative cuff tear remains unpredictable, the role of biological agents such as platelet-rich plasma and stem cells for postcuff repair augmentation is still under evaluation. The role of scaffolds in massive cuff tear is also being probed
    • …
    corecore