Experimental forced vibration responses of test houses during the Edwards Air Force Base phase of the national sonic boom test program
Experimental vibration studies were conducted on two houses to determine some of the dynamic response characteristics, resulting from sonic boom. The primary objectives of the vibration tests were to identify the mode shapes associated with the various frequencies determined from the sonic boom response data, and to obtain some basic information about the vibration behavior of buildings in general. The results are presented of forced sinusoidal vibration studies of some components of the test structures. Included are acceleration response data on selected walls, wall surface modal patterns, and vibration induced noise measurements at various locations in the test structures
Interior noise levels of two propeller-driven light aircraft
The relationships between aircraft operating conditions and interior noise and the degree to which ground testing can be used in lieu of flight testing for performing interior noise research were studied. The results show that the noise inside light aircraft is strongly influenced by the rotational speed of the engine and propeller. Both the overall noise and low frequency spectra levels were observed to decrease with increasing high speed rpm operations during flight. This phenomenon and its significance is not presently understood. Comparison of spectra obtained in flight with spectra obtained on the ground suggests that identification of frequency components and relative amplitude of propeller and engine noise sources may be evaluated on stationary aircraft
Review of subjective measures of human response to aircraft noise
The development of aircraft noise rating scales and indexes is reviewed up to the present time. Single event scales, multiple event indexes, and their interrelation with each other, are considered. Research requirements for further refinement and development of aircraft noise rating quantification factors are discussed
Description of Langley low-frequency noise facility and study of human response to noise frequencies below 50 cps
Test facility for determining human performance in very low frequency noise environment - physiological and psychological response
Description and research capabilities of the Langley Low Frequency Noise Facility
Description and research capabilities of low frequency noise facilit
Effects of aircraft noise on flight and ground structures
Acoustic loads measured on jet-powered STOL configurations are presented for externally blown and upper surface blown flap models ranging in size from a small laboratory model up to a full-scale aircraft model. The implications of the measured loads for potential acoustic fatigue and cabin noise are discussed. Noise transmission characteristics of light aircraft structures are presented. The relative importance of noise transmission paths, such as fuselage sidewall and primary structure, is estimated. Acceleration responses of a historic building and a residential home are presented for flyover noise from subsonic and supersonic aircraft. Possible effects on occupant comfort are assessed. The results from these three examples show that aircraft noise can induce structural responses that are large enough to require consideration in the design or operation of the aircraft
Inventory of aquatic contaminant flux arising from historical metal mining in England and Wales
The impact of discharges from abandoned metal and ironstone mines has been a much studied form of aquatic pollution in recent decades. Few attempts however, have been made to accurately determine the overall contaminant mass flux arising from abandoned mine sites at scales above catchment level. Such assessments are critical to determine the significance of former mining to national, regional and ultimately global trace metal flux. This paper presents the most comprehensive national survey to date across England and Wales of the total pollution burden discharged at source from abandoned non-coal mine sites. 338 discharges have been identified (from 4923 known abandoned metal mines) and while concurrent flow and contaminant concentration records are only available for around 30% of these, significant quantities of metals (and As) have been quantified to be discharged. A minimum of 193 tonnes of Zn, 18.5 tonnes of Pb, 0.64 tonnes Cd, 19.1 tonnes of Cu, 551 tonnes Fe, 72 tonnes Mn and 5.1 tonnes As are released in water discharges from abandoned non-coal mines to the surface water environment of England and Wales each year. Precautionary extrapolation of mass fluxes based on the frequency distribution of measured concentration and flow data, for discharges with absent data, suggests that the actual total mass flux for these contaminants could be up to 41% higher. The mass flux of Pb released from mines exceeds that of all currently permitted discharges (e.g. active industrial sites and wastewater treatment works) to surface waters across England and Wales, while those of As, Cd and Zn are of a similar magnitude. These data put into context the enduring legacy of historic mining on the water environment, highlighting its significance relative to more highly regulated polluting sites. Comparison of the figures with estimates of global trace metal flux suggests that the national total identified here is significant on a global scale
Concorde noise-induced building vibrations John F. Kennedy International Airport
The outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at six home sites along with the associated vibration levels in the walls, windows, and floors of these test homes. Limited subjective tests conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise showed that both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Preliminary results indicate that the relationship between window vibration and aircraft noise is: (1) linear, with vibration levels being accurately predicted from OASPL levels measured near the window; (2) consistent from flyover to flyover for a given aircraft type under approach conditions; (3) no different for Concorde than for other conventional jet transports (in the case of window vibrations induced under approach power conditions); and (4) relatively high levels of window vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde source characteristics
Concorde noise-induced building vibrations: John F. Kennedy International Airport
Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics
Concorde Noise-Induced Building Vibrations, Montgomery County, Maryland
A series of studies are reported to assess the noise induced building vibrations associated with Concorde operations. The levels of induced vibration and associated indoor/outdoor noise levels resulting from aircraft and nonaircraft events in selected homes, historic and other buildings near Dulles International Airport were recorded. The building response resulting from aircraft operations was found to be directly proportional to the overall sound pressure level and approximately independent of the aircraft type. The noise levels and, consequently, the response levels were observed to be higher for the Concorde operations than for the CTOL operations. Furthermore, the vibration could be closely reproduced by playing aircraft noise through a loudspeaker system located near the vibration measurement location. Nonaircraft events such as door closing were again observed to result in higher response levels than those induced by aircraft
- …