1,601 research outputs found

    Waste heat utilization in industrial processes

    Get PDF
    A survey is given of new developments in heat exchangers and heat pumps. With respect to practical applications, internal criteria for plant operation are discussed. Possibilities of government support are pointed out. Waste heat steam generators and waste heat aggregates for hot water generation or in some cases for steam superheating are used. The possibilities of utilization can be classified according to the economic improvements and according to their process applications, for example, gascooling. Examples are presented for a large variety of applications

    Cluster formation in quantum critical systems

    Full text link
    The presence of magnetic clusters has been verified in both antiferromagnetic and ferromagnetic quantum critical systems. We review some of the strongest evidence for strongly doped quantum critical systems (Ce(Ru0.24_{0.24}Fe0.76_{0.76})2_2Ge2_2) and we discuss the implications for the response of the system when cluster formation is combined with finite size effects. In particular, we discuss the change of universality class that is observed close to the order-disorder transition. We detail the conditions under which clustering effects will play a significant role also in the response of stoichiometric systems and their experimental signature.Comment: 5 pages; 2 figures; Internation Conference on Strongly Correlated Electron System

    Hyperostotic tympanic bone spicules in domestic and wild animal species

    Get PDF
    Hyperostotic tympanic bone spicules (HTBS), or "mucoperiosteal exostoses" (ME, syn.) are small, globular (>= 1 mm in diameter), mostly stalked and drumstick-like, bony structures, which arise from the inner wall of the tympanic bulla and project into the middle ear cavity. HTBS present as mineral densities inside the tympanic bulla on radiographs or computed tomographic (CT) images. They have previously been referred to as "otoliths" and were thought to represent mineral concretions secondary to otitis media. Recently, it was shown that HTBS actually consist of regularly composed bone tissue, covered by normal middle ear mucosa. So far, HTBS have only extensively been described in dogs, where they occur with a prevalence of up to >45%. A recent study detected ME, most likely representing HTBS, in the tympanic cavities of skeletonised skull bones of African lions. To estimate the occurrence of HTBS in other mammal species, the middle ears of adult animals of 78 different domestic, wild, and zoo species undergoing routine necropsy at the Institute of Veterinary Pathology of the LMU Munich, Germany were examined in the present study. HTBS were found in the tympanic bullae of carnivorous species, such as canids (wolf, fox), and in several large felid species (lion, tiger, leopard, cheetah). In contrast, HTBS were not present in domestic cats (more than to 200 cases), small carnivorous species such as mustelids, nor in any primate, ungulate, ruminant, pig, insectivore, or rodent species. The detectability of HTBS by CT of the tympanic bullae of large felids was demonstrated in an African lion. Histologically, HTBS consisted of mature lamellar bone, covered by periosteum and a partially ciliated, flat epithelium, regularly without any apparent inflammatory alterations. The present study demonstrates that HTBS may frequently occur in large felids and in different canid species. These findings should be taken into account when examining the middle ear, or interpreting bulla radiographs/CT-images of the respective species. However, the factors triggering the development of HTBS remain to be identified

    Microstrip superconducting quantum interference device amplifiers with submicron Josephson junctions: enhanced gain at gigahertz frequencies

    Full text link
    We present measurements of an amplifier based on a dc superconducting quantum interference device (SQUID) with submicron Al-AlOx-Al Josephson junctions. The small junction size reduces their self-capacitance and allows for the use of relatively large resistive shunts while maintaining nonhysteretic operation. This leads to an enhancement of the SQUID transfer function compared to SQUIDs with micron-scale junctions. The device layout is modified from that of a conventional SQUID to allow for coupling signals into the amplifier with a substantial mutual inductance for a relatively short microstrip coil. Measurements at 310 mK exhibit gain of 32 dB at 1.55 GHz.Comment: Version with high resolution figures at: http://physics.syr.edu/~bplourde/bltp-publications.ht

    Picovoltmeter for probing vortex dynamics in a single weak-pinning Corbino channel

    Full text link
    We have developed a picovoltmeter using a Nb dc Superconducting QUantum Interference Device (SQUID) for measuring the flux-flow voltage from a small number of vortices moving through a submicron weak-pinning superconducting channel. We have applied this picovoltmeter to measure the vortex response in a single channel arranged in a circle on a Corbino disk geometry. The circular channel allows the vortices to follow closed orbits without encountering any sample edges, thus eliminating the influence of entry barriers.Comment: 4 pages, 3 figures, submitted to Review of Scientific Instrument
    corecore