1,074 research outputs found

    Macroscopic study of time unsteady noise of an aircraft engine during static tests

    Get PDF
    Static tests of aircraft engines can exhibit greater than 10 db random unsteadiness of tone noise levels because flow disturbances that prevail near test site facilities are ingested. Presumably such changes are related to installation and test site features. Some properties of unsteady noise observed during tests of a Lycoming YF-102 turbofan engine are presented. Time and spatial variations in tone noise obtained from closely spaced far field and inlet duct microphones are displayed. Long to extremely short intermittent tone bursts are observed. Unsteadiness of the tone, its harmonics, and the broadband noise show little similarity. In the far field, identity of tone bursts is retained over a directivity angle of less than 10 deg. In the inlet duct, tone bursts appear to propagate axially but exhibit little circumferential similarity. They show only slight relationship to tone bursts observed in the far field. The results imply an intermittent generation of random mixtures of propagating duct modes

    Probing optomechanical correlations between two optical beams down to the quantum level

    Full text link
    Quantum effects of radiation pressure are expected to limit the sensitivity of second-generation gravitational-wave interferometers. Though ubiquitous, such effects are so weak that they haven't been experimentally demonstrated yet. Using a high-finesse optical cavity and a classical intensity noise, we have demonstrated radiation-pressure induced correlations between two optical beams sent into the same moving mirror cavity. Our scheme can be extended down to the quantum level and has applications both in high-sensitivity measurements and in quantum optics

    High-sensitivity optical measurement of mechanical Brownian motion

    Get PDF
    We describe an experiment in which a laser beam is sent into a high-finesse optical cavity with a mirror coated on a mechanical resonator. We show that the reflected light is very sensitive to small mirror displacements. We have observed the Brownian motion of the resonator with a very high sensitivity.Comment: 4 pages, 4 figures, RevTe

    Noise reduction in gravitational wave interferometers using feedback

    Full text link
    We show that the quantum locking scheme recently proposed by Courty {\it et al.} [Phys. Rev. Lett. {\bf 90}, 083601 (2003)] for the reduction of back action noise is able to significantly improve the sensitivity of the next generation of gravitational wave interferometers.Comment: 12 pages, 2 figures, in print in the Special Issue of J. Opt. B on Fluctuations and Noise in Photonics and Quantum Optic

    Beating quantum limits in interferometers with quantum locking of mirrors

    Full text link
    The sensitivity in interferometric measurements such as gravitational-wave detectors is ultimately limited by quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent experiments have shown that it is possible to reduce the thermal motion of a mirror by cold damping. The mirror motion is measured with an optomechanical sensor based on a high-finesse cavity, and reduced by a feedback loop. We show that this technique can be extended to lock the mirror at the quantum level. In gravitational-waves interferometers with Fabry-Perot cavities in each arms, it is even possible to use a single feedback mechanism to lock one cavity mirror on the other. This quantum locking greatly improves the sensitivity of the interferometric measurement. It is furthermore insensitive to imperfections such as losses in the interferometer

    Quantum noise in the position measurement of a cavity mirror undergoing Brownian motion

    Get PDF
    We perform a quantum theoretical calculation of the noise power spectrum for a phase measurement of the light output from a coherently driven optical cavity with a freely moving rear mirror. We examine how the noise resulting from the quantum back action appears among the various contributions from other noise sources. We do not assume an ideal (homodyne) phase measurement, but rather consider phase modulation detection, which we show has a different shot noise level. We also take into account the effects of thermal damping of the mirror, losses within the cavity, and classical laser noise. We relate our theoretical results to experimental parameters, so as to make direct comparisons with current experiments simple. We also show that in this situation, the standard Brownian motion master equation is inadequate for describing the thermal damping of the mirror, as it produces a spurious term in the steady-state phase fluctuation spectrum. The corrected Brownian motion master equation [L. Diosi, Europhys. Lett. {\bf 22}, 1 (1993)] rectifies this inadequacy.Comment: 12 pages revtex, 2 figure

    Contractive Schroedinger cat states for a free mass

    Get PDF
    Contractive states for a free quantum particle were introduced by Yuen [Yuen H P 1983 Phys. Rev. Lett. 51, 719] in an attempt to evade the standard quantum limit for repeated position measurements. We show how appropriate families of two- and three component ``Schroedinger cat states'' are able to support non-trivial correlations between the position and momentum observables leading to contractive behavior. The existence of contractive Schroedinger cat states is suggestive of potential novel roles of non-classical states for precision measurement schemes.Comment: 24 pages, 7 encapsulated eps color figures, REVTeX4 style. Published online in New Journal of Physics 5 (2003) 5.1-5.21. Higher-resolution figures available in published version. (accessible at http://www.njp.org/

    Isotope effect in superconductors with coexisting interactions of phonon and nonphonon mechanisms

    Full text link
    We examine the isotope effect of superconductivity in systems with coexisting interactions of phonon and nonphonon mechanisms in addition to the direct Coulomb interaction. The interaction mediated by the spin fluctuations is discussed as an example of the nonphonon interaction. Extended formulas for the transition temperature Tc and the isotope-effect coefficient alpha are derived for cases (a) omega_np omega_D, where omega_np is an effective cutoff frequency of the nonphonon interaction that corresponds to the Debye frequency omega_D in the phonon interaction. In case (a), it is found that the nonphonon interaction does not change the condition for the inverse isotope effect, i.e., mu^* > lambda_ph/2, but it modifies the magnitude of alpha markedly. In particular, it is found that a giant isotope shift occurs when the phonon and nonphonon interactions cancel each other largely. For instance, strong critical spin fluctuations may give rise to the giant isotope effect. In case (b), it is found that the inverse isotope effect occurs only when the nonphonon interaction and the repulsive Coulomb interaction, in total effect, work as repulsive interactions against the superconductivity. We discuss the relevance of the present result to some organic superconductors, such as kappa-(ET)2Cu(NCS)2 and Sr2RuO4 superconductors, in which inverse isotope effects have been observed, and briefly to high-Tc cuprates, in which giant isotope effects have been observed.Comment: 4 pages, 2 figures, (with jpsj2.cls, ver.1.2), v2:linguistic correction

    Stable nondegenerate optical parametric oscillation at degenerate frequencies in Na:KTP

    Get PDF
    We report the realization of a light source specifically designed for the generation of bright continuous-variable entangled beams and for Heisenberg-limited inteferometry. The source is a nondegenerate, single-mode, continuous-wave optical parametric oscillator in Na:KTP, operated at frequency degeneracy and just above threshold, which is also of interest for the study of critical fluctuations at the transition point. The residual frequency-difference jitter is ±\pm 150 kHz for a 3 MHz cold cavity half-width at half maximum. We observe 4 dB of photon-number-difference squeezing at 200 kHz. The Na:KTP crystal is noncritically phase-matched for a 532 nm pump and polarization crosstalk is therefore practically nonexistent
    • …
    corecore