6 research outputs found

    Function and failure of the fetal membrane : modelling the mechanics of the chorion and amnion

    Get PDF
    The fetal membrane surrounds the fetus during pregnancy and is a thin tissue composed of two layers, the chorion and the amnion. While rupture of this membrane normally occurs at term, preterm rupture can result in increased risk of fetal mortality and morbidity, as well as danger of infection in the mother. Although structural changes have been observed in the membrane in such cases, the mechanical behaviour of the human fetal membrane in vivo remains poorly understood and is challenging to investigate experimentally. Therefore, the objective of this study was to develop simplified finite element models to investigate the mechanical behaviour and rupture of the fetal membrane, particularly its constituent layers, under various physiological conditions. It was found that modelling the chorion and amnion as a single layer predicts remarkably different behaviour compared with a more anatomically-accurate bilayer, significantly underestimating stress in the amnion and under-predicting the risk of membrane rupture. Additionally, reductions in chorion-amnion interface lubrication and chorion thickness (reported in cases of preterm rupture) both resulted in increased membrane stress. Interestingly, the inclusion of a weak zone in the fetal membrane that has been observed to develop overlying the cervix would likely cause it to fail at term, during labour. Finally, these findings support the theory that the amnion is the dominant structural component of the fetal membrane and is required to maintain its integrity. The results provide a novel insight into the mechanical effect of structural changes in the chorion and amnion, in cases of both normal and preterm rupture

    Mussel-mimetic tissue adhesive for fetal membrane repair: an ex vivo evaluation

    Full text link
    Iatrogenic preterm prelabor rupture of membranes (iPPROM) remains the main complication after invasive interventions into the intrauterine cavity. Here, the proteolytic stability of mussel-mimetic tissue adhesive (mussel glue) and its sealing behavior on punctured fetal membranes are evaluated. The proteolytic degradation of mussel glue and fibrin glue were compared in vitro. Critical pressures of punctured and sealed fetal membranes were determined under close to physiological conditions using a custom-made inflation device. An inverse finite element procedure was applied to estimate mechanical parameters of mussel glue. Mussel glue was insensitive whereas fibrin glue was sensitive towards proteolytic degradation. Mussel glue sealed 3.7mm fetal membrane defect up to 60mbar (45mmHg) when applied under wet conditions, whereas fibrin glue needed dry membrane surfaces for reliable sealing. The mussel glue can be represented by a neo-Hookean material model with elastic coefficient C(1)=9.63kPa. Ex-vivo-tested mussel glue sealed fetal membranes and resisted pressures achieved during uterine contractions. Together with good stability in proteolytic environments, this makes mussel glue a promising sealing material for future applications

    Experimental and numerical methods to analyse deformation and damage in random fibrous networks

    No full text
    Deformation and damage behaviours of random fibrous networks are investigated with experimental and numerical methods at local (fibre) and global (specimen) levels. Nonwoven material was used as an example of fibrous network, with its individual fibres were extracted and tested with a universal testing system in order to assess their material properties. The fibres demonstrated a nonlinear time-dependent response to stretching. For analysis of notch sensitivity, undamaged nonwoven specimens and those with various notch shapes were analysed with fabric-level tensile tests and finite-element simulations. A level of strains around notch tips was tracked in simulations, demonstrating that the material was notch-sensitive, but load-transfer mechanisms were different than those in standard homogeneous materials. The notch shape also affected the rate of damage growth in the main directions. A good agreement between experimental and numerical damage patterns was observed. Also, the notch shape affected the strength and toughness of the fibrous network

    Multiaxial mechanical behavior of human fetal membranes and its relationship to microstructure

    Get PDF
    This study was directed to the measurement of the mechanical response of fetal membranes to physiologically relevant loading conditions. Characteristic mechanical parameters were determined and their relation to the microstructural constituents collagen and elastin as well as to the pyridinium cross-link concentrations analyzed. 51 samples from twelve fetal membranes were tested on a custom-built inflation device, which allows mechanical characterization within a multiaxial state of stress. Methods of nonlinear continuum mechanics were used to extract representative mechanical parameters. Established biochemical assays were applied for the determination of the collagen and elastin content. Collagen cross-link concentrations were determined by high-performance liquid chromatography measurements. The results indicate a distinct correlation between the mechanical parameters of high stretch stiffness and membrane tension at rupture and the biochemical data of collagen content and pyridinoline as well as deoxypyridinoline concentrations. No correlation was observed between the mechanical parameters and the elastin content. Moreover, the low stretch stiffness is, with a value of 105 ± 31 × 10(-3) N/ mm much higher for a biaxial state of stress compared to a uniaxial stress configuration. Determination of constitutive model equations leads to better predictive capabilities for a reduced polynomial hyperelastic model with only terms related to the second invariant, I (2), of the right Cauchy-Green deformation tensor. Relevant insights were obtained on the mechanical behavior of fetal membranes. Collagen and its cross-linking were shown to determine membrane's stiffness and strength for multiaxial stress states. Their nonlinear deformation behavior characterizes the fetal membranes as I (2) material

    Novel pathways of inflammation in human fetal membranes associated with preterm birth and preterm pre-labor rupture of the membranes

    No full text
    corecore