4,252 research outputs found
Standard arc welders provide high amperage direct current source
Standard arc welders or power supplies are hooked up in parallel or series connections to obtain an adequate supply of current or voltage for various purposes. This method provides maximum flexibility in a wide range of voltages and currents
Continuously operating induction plasma accelerator Patent
Continuous operation, single phased, induction plasma accelerator producing supersonic speed
A study of the possible preventive effects of muscular exercises and intermittent venous occlusion on the cardiovascular deconditioning observed after 10 days bed recumbency - Experimental design
Experiment designed to study preventive effects of muscular exercises on intermittent venous occlusion on cardiovascular deconditioning observed after 10 days bed recumbenc
NASA low- and medium-speed airfoil development
The status of NASA low and medium speed airfoil research is discussed. Effects of airfoil thickness-chord ratios varying from 9 percent to 21 percent on the section characteristics for a design lift coefficient of 0.40 are presented for the initial low speed family of airfoils. Also, modifications to the 17-percent low-speed airfoil to reduce the pitching-moment coefficient and to the 21-percent low speed airfoil results are shown for two new medium speed airfoils with thickness ratios of 13 percent and 17 percent and design-lift coefficients of 0.30. Applications of NASA-developed airfoils to general aviation aircraft are summarized
Low-speed aerodynamic characteristics of a 13-percent-thick airfoil section designed for general aviation applications
Wind-tunnel tests were conducted to determine the low-speed section characteristics of a 13 percent-thick airfoil designed for general aviation applications. The results were compared with NACA 12 percent-thick sections and with the 17 percent-thick NASA airfoil. The tests were conducted ovar a Mach number range from 0.10 to 0.35. Chord Reynolds numbers varied from about 2,000,000 to 9,000,000
Wind-tunnel results for an improved 21-percent-thick low-speed airfoil section
Low speed wind tunnel tests were conducted to evaluate the effects on performance of modifying a 23 percent thick low speed airfoil. The airfoil contour was altered to reduce the upper-surface adverse pressure gradient and hence reduce boundary layer separation. The chord Reynolds number varied from about 2,000,000 to 9,000,000
An Exploratory Investigation of the Effects of a Thin Plastic Film Cover on the Profile Drag of an Aircraft Wing Panel
Exploratory wind tunnel tests were conducted on a large chord aircraft wing panel to evaluate the potential for drag reduction resulting from the application of a thin plastic film cover. The tests were conducted at a Mach number of 0.15 over a Reynolds number range from about 7 x 10 to the 6th power to 63 x 10 to the 6th power
Suppression of the superconducting critical current of Nb in bilayers of Nb/SrRuO3
In bilayers consisting of ferromagnetic and superconducting films, the
ferromagnetic film in its domain state induces inhomogeneous distribution of
magnetic fields in the superconducting film. When the ferromagnetic film has
bubble magnetic domains in a labyrinth structure, it has been found that the
pinning of the vortices increases; hence, the critical current of the
superconducting film becomes larger. Here we study the effect of parallel
ferromagnetic domain structure in Nb/SrRuO3 on the critical current of Nb with
current flowing perpendicularly to the domains and find that in this case the
ferromagnetic domain structure decreases the critical current
VLBI Astrometry of the Stellar Image of U Herculis, Amplified by the 1667 OH Maser
The OH 1667 MHz maser in the circumstellar shell around the Mira variable U
Herculis has been observed with the NRAO Very Long Baseline Array (VLBA) at 6
epochs, spread over 4 years. Using phase referencing techniques the position of
the most blue-shifted maser spot was monitored with respect to two
extra-galactic radio sources. The absolute radio positions of the maser can be
compared with the stellar optical position measured by the Hipparcos satellite
to 15 mas accuracy. This confirms the model in which one of the maser spots
corresponds to the stellar continuum, amplified by the maser. The stellar
proper motion and the annual parallax (5.3 +/- 2.1 mas) were measured.Comment: 6 pages, 4 figures; to be published in A&
The Challenges Facing Training in Pediatric Surgery Worldwide
Like most specialties, pediatric surgery is becoming more complex, and changes to health systems have not always been in the best interests of trainees or their surgical teachers. This paper outlines four of the current challenges faced by training boards in pediatric surgery worldwide, and documents their implications for the future training of pediatric surgeons
- …
