4 research outputs found

    Quantitative Detection of Biological Nanovesicles in Drops of Saliva Using Microcantilevers

    Get PDF
    Extracellular nanovesicles (EVs) are lipid-based vesicles secreted by cells and are present in all bodily fluids. They play a central role in communication between distant cells and have been proposed as potential indicators for the early detection of a wide range of diseases, including different types of cancer. However, reliable quantification of a specific subpopulation of EVs remains challenging. The process is typically lengthy and costly and requires purification of relatively large quantities of biopsy samples. Here, we show that microcantilevers operated with sufficiently small vibration amplitudes can successfully quantify a specific subpopulation of EVs directly from a drop (0.1 mL) of unprocessed saliva in less than 20 min. Being a complex fluid, saliva is highly non-Newtonian, normally precluding mechanical sensing. With a combination of standard rheology and microrheology, we demonstrate that the non-Newtonian properties are scale-dependent, enabling microcantilever measurements with a sensitivity identical to that in pure water when operating at the nanoscale. We also address the problem of unwanted sensor biofouling by using a zwitterionic coating, allowing efficient quantification of EVs at concentrations down to 0.1 μg/mL, based on immunorecognition of the EVs’ surface proteins. We benchmark the technique on model EVs and illustrate its potential by quantifying populations of natural EVs commonly present in human saliva. The method effectively bypasses the difficulty of targeted detection in non-Newtonian fluids and could be used for various applications, from the detection of EVs and viruses in bodily fluids to the detection of molecular clusters or nanoparticles in other complex fluids

    Direct Visualization of Single Ions in the Stern Layer of Calcite

    No full text
    Calcite is among the most abundant minerals on earth and plays a central role in many environmental and geochemical processes. Here we used amplitude modulation atomic force microscopy (AFM) operated in a particular regime to visualize single ions close to the (101̅4) surface of calcite in solution. The results were acquired at equilibrium, in aqueous solution containing different concentrations of NaCl, RbCl, and CaCl<sub>2</sub>. The AFM images provide a direct and atomic-level picture of the different cations adsorbed preferentially at certain locations of the calcite–water interface. Highly ordered water layers at the calcite surface prevent the hydrated ions from directly interacting with calcite due to the energy penalty incurred by the necessary restructuring of the ions’ solvation shells. Controlled removal of the adsorbed ions from the interface by the AFM tip provides indications about the stability of the adsorption site. The AFM results show the familiar “row pairing” of the carbonate oxygen atoms, with the adsorbed monovalent cations located adjacent to the most prominent oxygen atoms. The location of adsorbed cations near the surface appears better defined for monovalent ions than for Ca<sup>2+</sup>, consistent with the idea that Ca<sup>2+</sup> ions remain further away from the surface of calcite due to their larger hydration shell. The precise distance between the different hydrated ions and the surface of calcite is quantified using MD simulation. The preferential adsorption sites found by MD as well as the ion residence times close to the surface support the AFM findings, with Na<sup>+</sup> ions dwelling substantially longer and closer to the calcite surface than Ca<sup>2+</sup>. The results also bring new insights into the problem of the Stern and electrostatic double layer at the surface of calcite, showing that parameters such as the thickness of the Stern layer can be highly ion dependent

    Electrical Method to Quantify Nanoparticle Interaction with Lipid Bilayers

    No full text
    Understanding as well as rapidly screening the interaction of nanoparticles with cell membranes is of central importance for biological applications such as drug and gene delivery. Recently, we have shown that “striped” mixed-monolayer-coated gold nanoparticles spontaneously penetrate a variety of cell membranes through a passive pathway. Here, we report an electrical approach to screen and readily quantify the interaction between nanoparticles and bilayer lipid membranes. Membrane adsorption is monitored through the capacitive increase of suspended planar lipid membranes upon fusion with nanoparticles. We adopt a Langmuir isotherm model to characterize the adsorption of nanoparticles by bilayer lipid membranes and extract the partition coefficient, <i>K</i>, and the standard free energy gain by this spontaneous process, for a variety of sizes of cell-membrane-penetrating nanoparticles. We believe that the method presented here will be a useful qualitative and quantitative tool to determine nanoparticle interaction with lipid bilayers and consequently with cell membranes

    In Situ Mapping of the Molecular Arrangement of Amphiphilic Dye Molecules at the TiO<sub>2</sub> Surface of Dye-Sensitized Solar Cells

    No full text
    Amphiphilic sensitizers are central to the function of dye-sensitized solar cells. It is known that the cell’s performance depends on the molecular arrangement and the density of the dye on the semiconductor surface, but a molecular-level picture of the cell–electrolyte interface is still lacking. Here, we present subnanometer in situ atomic force microscopy images of the Z907 dye at the surface of TiO<sub>2</sub> in a relevant liquid. Our results reveal changes in the conformation and the lateral arrangement of the dye molecules, depending on their average packing density on the surface. Complementary quantitative measurements on the ensemble of the film are obtained by the quartz-crystal microbalance with dissipation technique. An atomistic picture of the dye coverage-dependent packing, the effectiveness of the hydrophobic alkyl chains as blocking layer, and the solvent accessibility is obtained from molecular dynamics simulations
    corecore