259 research outputs found

    Automation of contouring and planning in Radiotherapy

    Get PDF

    Automation of contouring and planning in Radiotherapy

    Get PDF

    Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease : a multicentre observational study

    Get PDF
    Background Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. Methods In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory selfrecordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. Findings From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81.0-95.6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0.96 (0.95-0.97). The mean false positive rate during daily life conditions was 4.19% (95% CI 3.29-5.10). The sensitivity for the target conditions was 0.87 (55 of 63; 95% CI 0.77-0.93) for acute coronary artery occlusion, 0.95 (54 of 57; 0.86-0.98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1.00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p<0.0001). The proportion of total variation in study estimates due to heterogeneity between patients (I-2) was low (12.6%). The area under the receiver operator characteristics curve was 0.973 (95% CI 0.956-0.990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study. Interpretation Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. Copyright (C) 2019 The Author(s). Published by Elsevier Ltd

    Single-cell copy number variation detection

    Get PDF
    Detection of chromosomal aberrations from a single cell by array comparative genomic hybridization (single-cell array CGH), instead of from a population of cells, is an emerging technique. However, such detection is challenging because of the genome artifacts and the DNA amplification process inherent to the single cell approach. Current normalization algorithms result in inaccurate aberration detection for single-cell data. We propose a normalization method based on channel, genome composition and recurrent genome artifact corrections. We demonstrate that the proposed channel clone normalization significantly improves the copy number variation detection in both simulated and real single-cell array CGH data

    Development of a novel ozone- and photo-stable HyPer5 red fluorescent dye for array CGH and microarray gene expression analysis with consistent performance irrespective of environmental conditions

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Array-based comparative genomic hybridization (CGH) and gene expression profiling have become vital techniques for identifying molecular defects underlying genetic diseases. Regardless of the microarray platform, cyanine dyes (Cy3 and Cy5) are one of the most widely used fluorescent dye pairs for microarray analysis owing to their brightness and ease of incorporation, enabling high level of assay sensitivity. However, combining both dyes on arrays can become problematic during summer months when ozone levels rise to near 25 parts per billion (ppb). Under such conditions, Cy5 is known to rapidly degrade leading to loss of signal from either "homebrew" or commercial arrays. Cy5 can also suffer disproportionately from dye photobleaching resulting in distortion of (Cy5/Cy3) ratios used in copy number analysis. Our laboratory has been active in fluorescent dye research to find a suitable alternative to Cy5 that is stable to ozone and resistant to photo-bleaching. Here, we report on the development of such a dye, called HyPer5, and describe its' exceptional ozone and photostable properties on microarrays.</p> <p>Results</p> <p>Our results show HyPer5 signal to be stable to high ozone levels. Repeated exposure of mouse arrays hybridized with HyPer5-labeled cDNA to 300 ppb ozone at 5, 10 and 15 minute intervals resulted in no signal loss from the dye. In comparison, Cy5 arrays showed a dramatic 80% decrease in total signal during the same interval. Photobleaching experiments show HyPer5 to be resistant to light induced damage with 3- fold improvement in dye stability over Cy5. In high resolution array CGH experiments, HyPer5 is demonstrated to detect chromosomal aberrations at loci 2p21-16.3 and 15q26.3-26.2 from three patient sample using bacterial artificial chromosome (BAC) arrays. The photostability of HyPer5 is further documented by repeat array scanning without loss of detection. Additionally, HyPer5 arrays are shown to preserve sensitivity and data quality from gene expression experiments.</p> <p>Conclusion</p> <p>HyPer5 is a red fluorescent dye that behaves functionally similar to Cy5 except in stability to ozone and light. HyPer5 is demonstrated to be resistant to ozone at up to 300 ppb, levels significantly higher than commonly observed during summer months. Consequently, HyPer5 dye can be used in parallel with Cy3 under any environmental conditions in array experiments.</p

    Validation of fully automated VMAT plan generation for library-based plan-of-the-day cervical cancer radiotherapy

    Get PDF
    Purpose: To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer. Material and Methods: Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid. Results: All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p<0.001). For 41/44 autoVMAT plans, SB V45Gy was lower than for manVMAT (p<0.001, average reduction 30.3%), while SB V15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs. sponsored the appointment of STH for this project. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Conclusions: Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible

    IMRT for image-guided single vocal cord irradiation

    Get PDF
    Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates

    Fully automated treatment planning of spinal metastases - A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation

    Get PDF
    _Background:_ Planning for Volumetric Modulated Arc Therapy (VMAT) may be time consuming and its use is limited by available staff resources. Automated multicriterial treatment planning can eliminate this bottleneck. We compared automatically created (auto) VMAT plans generated by Erasmus-iCycle to manually created VMAT plans for treatment of spinal metastases. _Methods:_ Forty-two targets in 32 patients were analyzed. Lungs and kidneys were defined as organs at risk (OARs). Twenty-two patients received radiotherapy on kidney levels, 17 on lung levels, and 3 on both levels. _Results:_ All Erasmus-iCycle plans were clinically acceptable. When compared to manual plans, planning target volume (PTV) coverage of auto plans was significantly better. The Homogeneity Index did not differ significantly between the groups. Mean dose to OARs was lower in auto plans concerning both kidneys and the left lung. One hotspot (>110% of D50%) occurred in the spinal cord of one auto plan (33.2 Gy, D50%: 30 Gy). Treatment time was 7% longer in auto plans. _Conclusions:_ Erasmus-iCycle plans showed better target coverage and sparing of OARs at the expense of minimally longer treatment times (for which no constraint was set)
    corecore