18 research outputs found

    Using extra systoles and the micro-fluid challenge to predict fluid responsiveness during cardiac surgery

    Get PDF
    Fluid responsiveness prediction is difficult during cardiac surgery. The micro-fluid challenge (micro-FC; rapid central infusion of 50 ml) and the extrasystolic method utilising post-extrasystolic preload increases may predict fluid responsiveness. Two study windows during coronary artery bypass graft surgery were defined, 1: After anaesthesia induction until surgical incision, 2: Left internal mammarian artery surgical preparation period. Each window consisted of 10-15 min observation for extrasystoles before a micro-FC was performed, after which a traditional fluid challenge (FC) was performed (5 ml/kg). Extrasystolic and micro-FC induced changes in hemodynamic variables were derived as predictors of fluid responsiveness defined as stroke volume increasing > 10% following FC. 61 patients were studied. Post-ectopic changes in pulse pressure (PP) predicted fluid responsiveness with receiver operating characteristic area (AUC) of 0.69 [CI 0.40;0.97] in the first study window and 0.64 [0.44;0.86] in the second window. Other post-ectopic predictors such as pre-ejection period (PEP) and systolic blood pressure (SBP) had similar or lower AUCs. Heart rate was 52.9 (SD +/- 8.4) min(- 1) and 53.6 (+/- 8.8) min(- 1) in the two study windows. Micro-FC induced changes in PEP had AUC of 0.74 [0.57;0.90] in the first window and 0.60 [0.40;0.76] in the second window. Correcting micro-FC induced changes in PEP for the micro-FC induced changes in heart rate had AUCs of 0.84 [0.70;0.97] in the first window and 0.63 [0.47;0.79] in the second window. The investigated methods revealed insufficient validity during cardiac surgery. RR interval corrected changes during a micro-FC should be investigated further. Trial registration Clinicaltrials.gov: NCT03002129

    Year in review in journal of clinical monitoring and computing 2014: cardiovascular and hemodynamic monitoring

    No full text
    Hemodynamic instability is a common sign in critically ill patients and its importance has been increasingly recognized during the last 20 years. Indeed, It is now appreciated that an adequate hemodynamic monitoring associated to reactive vigorous therapy is able to decrease the present ominous prognostic sign. In this regard, the Journal of Clinical Monitoring and Computing (JCMC) has become an ideal platform for publishing cardiovascular and hemodynamic monitoring-related research, as reflected by an increasing number of articles related to this topic and published in the recent years. To highlight this new progress, the journal decided to print a review on some papers published last year in the JCMC and related to cardiac output monitoring and cardiovascular functions
    corecore