69 research outputs found

    In vitro comparative study on the mechanical behavior of Zirconia and Polyetheretherketone in applied dental sciences

    Get PDF
    OBJECTIVE: Recently, Zirconia and polyaryletherketone (PEEK) have attracted increasing interest as reliable and safe materials in dental applications, mainly because of their good biomechanical characteristics. The aim of this study was to investigate the response to different loads by prosthetic frameworks for supported fixed partial dentures (FPDs), thus simulating osseointegrated implants. MATERIALS AND METHODS: The specimens were divided into two groups (n= 5 each). Group A: FDPs in zirconia-ceramic; Group B: FDPs in PEEK-composite. These 2 groups were subjected to vertical loads so to evaluate structural deformation; then, they have been analyzed by scanning electron microscopy (SEM) at different magnifications. RESULTS: In tested samples, different types of mechanical failures have been observed. In Zirconia-specimens, chipping is the main failure noticed in this study, mostly in distal margins of the structure. Also, peek-specimens show failure and fracture. CONCLUSIONS: Zirconia and PEEK could be considered both good materials, but several investigations are needed to use these materials as an alternative to metals for fixed partial dentures

    Root canal morphology of primary maxillary second molars:a micro-computed tomography analysis

    Get PDF
    Aim Successful endodontic treatment of primary teeth requires comprehensive knowledge and understanding of root canal morphology. The purpose of this study was to investigate the root canal configurations of primary maxillary second molars using micro-computed tomography. Methods Extracted human primary maxillary second molars (n = 57) were scanned using micro-computed tomography and reconstructed to produce three-dimensional models. Each root canal system was analysed qualitatively according to Vertucci's classification. Results 22.8% (n = 13) of the sample presented with the fusion of the disto-buccal and palatal roots; of these, Type V was the most prevalent classification. For teeth with three separate roots (n = 44), the most common root canal type was Type 1 for the palatal canal (100%) and disto-buccal canal (77.3%) and Type V for the mesio-buccal canal (36.4%). Overall, 7% (n = 4) of mesio-buccal canals were 'unclassifiable'. Conclusion The root canal systems of primary maxillary second molars were not only complex but had a range of configurations that may contribute to unfavourable clinical outcomes after endodontic treatment

    In vitro comparative study on the mechanical behavior of Zirconia and Polyetheretherketone in applied dental sciences

    Get PDF
    OBJECTIVE: Recently, Zirconia and polyaryletherketone (PEEK) have attracted increasing interest as reliable and safe materials in dental applications, mainly because of their good biomechanical characteristics. The aim of this study was to investigate the response to different loads by prosthetic frameworks for supported fixed partial dentures (FPDs), thus simulating osseointegrated implants. MATERIALS AND METHODS: The specimens were divided into two groups (n= 5 each). Group A: FDPs in zirconia-ceramic; Group B: FDPs in PEEK-composite. These 2 groups were subjected to vertical loads so to evaluate structural deformation; then, they have been analyzed by scanning electron microscopy (SEM) at different magnifications. RESULTS: In tested samples, different types of mechanical failures have been observed. In Zirconia-specimens, chipping is the main failure noticed in this study, mostly in distal margins of the structure. Also, peek-specimens show failure and fracture. CONCLUSIONS: Zirconia and PEEK could be considered both good materials, but several investigations are needed to use these materials as an alternative to metals for fixed partial dentures

    Root Canal Anatomy of Maxillary and Mandibular Teeth

    Get PDF
    It is a common knowledge that a comprehensive understanding of the complexity of the internal anatomy of teeth is imperative to ensure successful root canal treatment. The significance of canal anatomy has been emphasized by studies demonstrating that variations in canal geometry before cleaning, shaping, and obturation procedures had a greater effect on the outcome than the techniques themselves. In recent years, significant technological advances for imaging teeth, such as CBCT and micro-CT, respectively, have been introduced. Their noninvasive nature allows to perform in vivo anatomical studies using large populations to address the influence of several variables such as ethnicity, aging, gender, and others, on the root canal anatomy, as well as to evaluate, quantitatively and/or qualitatively, specific and fine anatomical features of a tooth group. The purpose of this chapter is to summarize the morphological aspects of the root canal anatomy published in the literature of all groups of teeth and illustrate with three-dimensional images acquired from micro-CT technology.info:eu-repo/semantics/publishedVersio

    Mechanical evaluation and FEM analysis of stress in fixed partial dentures zirconium-ceramic

    Get PDF
    Over the last several years, the Finite Element Analysis (FEM) has been widely recognized as a reference method in different fields of study, to simulate the distribution of mechanical stress, in order to evaluate the relative distribution of loads of different nature. The aim of this study is to investigate through the FEM analysis the stress distribution in fixed prostheses that have a core in Zirconia and a ceramic veneer supported by implants. In this work we investigated the mechanical flexural strength of a ceramic material (Noritake®) and a of zirconium framework (Zircodent®) and the effects of the manufacturing processes of the material commonly performed during the production of fixed prostheses with CAD/CAM technology. Specifically three point bending mechanical tests were performed (three-point-bending) (1-3), using a machine from Test Equipment Instron 5566®, on two structures in zirconium framework-ceramic (structures supported by two implant abutments with pontic elements 1 and 2). A further in-depth analysis on the mechanical behavior in flexure of the specimens was conducted carrying out FEM studies in order to compare analog and digital data. The analysis of the data obtained showed that the stresses are distributed in a different way according to the intrinsic elasticity of the structure. The analysis of FPD with four elements, the stresses are mainly concentrated on the surface of the load, while, in the FPD of three elements, much more rigid, the stresses are concentrated near the inner margins of the abutments. The concentration of many stresses in this point could be correlated to chipping (4) that is found in the outer edges of the structure, as a direct result of the ceramic brittleness which opposes the resilience of the structure subjected to bending. The analysis of the UY linear displacement confirms previous data, showing, in a numerical way, that the presence of the ceramic is related to the lowering of the structure. So, the reference values are those of the linear lowering obtained in the Mechanical Test and in our FEM analysis. • zirconium framework with four elements 4,227 10-2mm. • zirconium framework with ceramic structure with four elements 2,266 10-2 mm. That suggests that the presence of ceramics halves the flexion capabilities of the prosthetic materials

    Three-point bending test simulation on implant FPDS with a bio-faithful model

    No full text
    It is well known by previous important studies that mandible flexes during different jaw movements. According to this assumption it is very important to know how implant supported fixed partial dentures could restrict mandibular movements and, could lead to excess strain accumulation that could modify the resolution of implant treatment. The aim of our project is to create a bio-faithful model able to recreate mandibular movements, during three point bending test methods of (FIXED -PARTIAL -DENTURES) FPDs, to avoid a not flexible metal base, where models' properties doesn't allow to obtain a bio-faithful simulation during testing phases
    • …
    corecore