1,553 research outputs found

    (Un)anticipated monetary policy in a DSGE model with a shadow banking system : [Version 21 Juni 2012]

    Get PDF
    Motivated by the U.S. events of the 2000s, we address whether a too low for too long interest rate policy may generate a boom-bust cycle. We simulate anticipated and unanticipated monetary policies in state-of-the-art DSGE models and in a model with bond financing via a shadow banking system, in which the bond spread is calibrated for normal and optimistic times. Our results suggest that the U.S. boom-bust was caused by the combination of (i) too low for too long interest rates, (ii) excessive optimism and (iii) a failure of agents to anticipate the extent of the abnormally favorable conditions

    Monetary policy shocks in a DSGE model with a shadow banking system

    Get PDF
    This paper is motivated by the recent financial crisis and addresses whether a “too low for too long” interest rate policy may generate a boom-bust cycle. We suggest a model in which a microfounded shadow banking sector is included in an otherwise state-of-the-art DSGE model. When faced with perverse incentives, financial intermediaries within the shadow banking sector can divert a fraction of stockholders’ profits for their own benefits and extend credit at a discounted rate. The model predicts that long periods of accommodative monetary policy do create the preconditions for, but do not cause per se, a boom-bust cycle. Rather, it is the combination of a persistent monetary ease with microeconomic distortions in the financial system that causes a boom-bust.monetary policy; DSGE model; shadow banking system; boom-bust

    Photo-physical properties of He-related color centers in diamond

    Get PDF
    Diamond is a promising platform for the development of technological applications in quantum optics and photonics. The quest for color centers with optimal photo-physical properties has led in recent years to the search for novel impurity-related defects in this material. Here, we report on a systematic investigation of the photo-physical properties of two He-related (HR) emission lines at 535 nm and 560 nm created in three different diamond substrates upon implantation with 1.3 MeV He+ ions and subsequent annealing. The spectral features of the HR centers were studied in an "optical grade" diamond substrate as a function of several physical parameters, namely the measurement temperature, the excitation wavelength and the intensity of external electric fields. The emission lifetimes of the 535 nm and 560 nm lines were also measured by means of time-gated photoluminescence measurements, yielding characteristic decay times of (29 +- 5) ns and (106 +- 10) ns, respectively. The Stark shifting of the HR centers under the application of an external electrical field was observed in a CVD diamond film equipped with buried graphitic electrodes, suggesting a lack of inversion symmetry in the defects' structure. Furthermore, the photoluminescence mapping under 405 nm excitation of a "detector grade" diamond sample implanted at a 1x1010 cm-2 He+ ion fluence enabled to identify the spectral features of both the HR emission lines from the same localized optical spots. The reported results provide a first insight towards the understanding of the structure of He-related defects in diamond and their possible utilization in practical applicationsComment: 9 pages, 3 figure

    Spectroscopic properties and radiation damage investigation of a diamond based Schottky diode for ion-beam therapy microdosimetry

    Get PDF
    In this work, a detailed analysis of the properties of a novel microdosimeter based on a synthetic single crystal diamond is reported. Focused ion microbeams were used to investigate the device spectropscopic properties as well as the induced radiation damageeffects. A diamond based Schottky diode was fabricated by chemical vapor deposition with a very thin detecting region, about 400 nm thick (approximately 1.4 μm water equivalent thickness), corresponding to the typical size in microdosimetric measurements. A 200 × 200 μm2 square metallic contact was patterned on the diamond surface by standard photolithography to define the sensitive area. Experimental measurements were carried out at the Ruder Boškovic′ Institute microbeam facility using 4 MeV carbon and 5 MeV silicon ions. Ion beam induced charge maps were employed to characterize the microdosimeter response in terms of its charge collection properties. A stable response with no evidence of polarization or memory effects was observed up to the maximum investigated ion beam flux of about 1.7 × 109 ions·cm−2·s−1. A homogeneity of the response about 6% was found over the sensitive region with a well-defined confinement of the response within the active area. Tests of the radiation damageeffect were performed by selectively irradiating small areas of the device with different ion fluences, up to about 1012 ions/cm2. An exponential decrease of the charge collection efficiency was observed with a characteristic decay constant of about 4.8 MGy and 1 MGy for C and Si ions, respectively. The experimental data were analyzed by means of GEANT4 Monte Carlo simulations. A direct correlation between the diamond damaging effect and the Non Ionizing Energy Loss (NIEL) fraction was found. In particular, an exponential decay of the charge collection efficiency with an exponential decay as a function of NIEL is observed, with a characteristic constant of about 9.3 kGy-NIEL for both carbon and silicon ions

    Spectrometric performances of monocrystalline artificial diamond detectors operated at high temperature

    Get PDF

    Dedicated multichannel readout ASIC coupled with single crystal diamond for dosimeter application

    Get PDF
    This paper reports on the tests of a low-noise, multi-channel readout integrated circuit used as a readout electronic front-end for a diamond multi-pixel dosimeter. The system is developed for dose distribution measurement in radiotherapy applications. The first 10-channel prototype chip was designed and fabricated in a 0.18 um CMOS process. Every channel includes a charge integrator with a 10 pF capacitor and a double slope A/D converter. The diamond multi-pixel detector, based on CVD synthetic single crystal diamond Schottky diodes, is made by a 3 × 3 sensor matrix. The overall device has been tested under irradiation with 6 MeV radio therapeutic photon beams at the Policlinico ``Tor Vergata'' (PTV) hospital. Measurements show a 20 fA RMS leakage current from the front-end input stage and a negligible dark current from the diamond detector, a stable temporal response and a good linear behaviour as a function of both dose and dose rate. These characteristics were common to each tested channel

    Neutron spectrometer for fast nuclear reactors

    Get PDF
    In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on 6^6Li into α\alpha and tt whose total energy comprises the initial neutron energy and the reaction QQ-value. The 6^6LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2×104\times 10^{-4} to 3.5×108\times 10^{-8} for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the 6^6Li(n,α\alpha)tt cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.Comment: submitted to NI

    A novel microdosimeter based upon artificial single crystal diamond

    Get PDF

    Numerical solution of linear models in economics: The SP-DG model revisited

    Get PDF
    In general, complex and large dimensional models are needed to solve real economic problems. Due to these characteristics, there is either no analytical solution for them or they are not attainable. As a result, solutions can be only obtained through numerical methods. Thus, the growing importance of computers in Economics is not surprising. This paper focuses on an implementation of the SP-DG model, using Matlab,developed by the students as part of the Computational Economics course. We also discuss some of our teaching/learning experience within the course, given for the first time in the FEP Doctoral Programme in Economics.SP-DG Model, Output, Inflation, Numerical Simulation, Teaching of Economics

    Analysis of the Response of CVD Diamond Detectors for UV and sX-Ray Plasma Diagnostics Installed at JET

    Get PDF
    Abstract Diamond detectors are very promising candidates for plasma diagnostics in a harsh environment. In fact, they have several proprieties which make them suitable for magnetic fusion devices: radiation hardness, high thermal conductivity, high resistivity, high carrier mobility and a large bandgap (5.5 eV). The latter makes them insensitive to visible radiation and allows low noise measurements without any cooling. In 2008 two CVD (Chemical Vapour Deposition) single crystal diamond (SCD) detectors were installed at the JET tokamak as extreme UV and soft X-Ray diagnostics [1]. In this work the neutron background in these detectors was measured shielding the UV and soft X-Ray radiation by closing a local vacuum valve. The UV detector was found to be insensitive to the neutron flux, while the soft X Ray detector signal exhibited spikes during the highest neutron rate pulse (neutron rate 10 16 n / s , which corresponds to a flux of φ n ∼10 5 n / cm 2 s in the detector location). These spikes were found to be due to the (n,p) reaction within the plastic filter in front of the soft X-Ray detector. The UV SCD was also used to perform time of flight (ToF) measurements in laser ablation experiments. ToFs were found to be an order of magnitude higher than expected if only the drift velocity is considered. This discrepancy could be due to a delay between the arrival time of the impurities in the plasma and their emission in an energy range which SCD is sensitive to ( Eph >5.5 eV). The delay is found to be comparable with the expected ionization times for edge plasma conditions
    corecore