207 research outputs found
Mining and analysis of audiology data to find significant factors associated with tinnitus masker
Objectives: The objective of this research is to find the factors associated with tinnitus masker from the literature, and by using the large amount of audiology data available from a large NHS (National Health Services, UK) hearing aid clinic. The factors evaluated were hearing impairment, age, gender, hearing aid type, mould and clinical comments.
Design: The research includes literature survey for factors associated with tinnitus masker, and performs the analysis of audiology data using statistical and data mining techniques.
Setting: This research uses a large audiology data but it also faced the problem of limited data for tinnitus.
Participants: It uses 1,316 records for tinnitus and other diagnoses, and 10,437 records of clinical comments from a hearing aid clinic.
Primary and secondary outcome measures: The research is looking for variables associated with tinnitus masker, and in future, these variables can be combined into a single model to develop a decision support system to predict about tinnitus masker for a patient.
Results: The results demonstrated that tinnitus maskers are more likely to be fit to individuals with milder forms of hearing loss, and the factors age, gender, type of hearing aid and mould were all found significantly associated with tinnitus masker. In particular, those patients having Age<=55 years were more likely to wear a tinnitus masker, as well as those with milder forms of hearing loss. ITE (in the ear) hearing aids were also found associated with tinnitus masker. A feedback on the results of association of mould with tinnitus masker from a professional audiologist of a large NHS (National Health Services, UK) was also taken to better understand them. The results were obtained with different accuracy for different techniques. For example, the chi-squared test results were obtained with 95% accuracy, for Support and Confidence only those results were retained which had more than 1% Support and 80% Confidence.
Conclusions: The variables audiograms, age, gender, hearing aid type and mould were found associated with the
choice of tinnitus masker in the literature and by using statistical and data mining techniques. The further work in this research would lead to the development of a decision support system for tinnitus masker with an explanation that how that decision was obtained
Increased Handpiece Speeds without Air Coolant: Aerosols and Thermal Impact.
This study assessed the impact of increased speed of high-speed contra-angle handpieces (HSCAHs) on the aerosolization of a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) surrogate virus and any concomitant thermal impact on dental pulp. A bacteriophage phantom-head model was used for bioaerosol detection. Crown preparations were performed with an NSK Z95L Contra-Angle 1:5 (HSCAH-A) and a Bien Air Contra-Angle 1:5 Nova Micro Series (HSCAH-B) at speeds of 60,000, 100,000, and 200,000 revolutions per minute (rpm), with no air coolant. Bioaerosol dispersal was measured with Φ6-bacteriophage settle plates, air sampling, and particle counters. Heating of the internal walls of the pulp chambers during crown preparation was assessed with an infrared camera with HSCAH-A and HSCAH-B at 200,000 rpm (water flows ≈15 mL min−1 and ≈30 mL min−1) and an air-turbine control (≈23.5 mL min−1) and correlated with remaining tissue thickness measurements. Minimal bacteriophage was detected on settle or air samples with no notable differences observed between handpieces or speeds (P > 0.05). At all speeds, maximum settled aerosol and average air detection was 1.00 plaque-forming units (pfu) and 0.08 pfu/m3, respectively. Irrespective of water flow rate or handpiece, both maximum temperature (41.5°C) and temperature difference (5.5°C) thresholds for pulpal health were exceeded more frequently with reduced tissue thickness. Moderate and strong negative correlations were observed based on Pearson’s correlation coefficient, between remaining dentine thickness and either differential (r = −0.588) or maximum temperature (r = −0.629) measurements, respectively. Overall, HSCAH-B generated more thermal energy and exceeded more temperature thresholds compared to HSCAH-A. HSCAHs without air coolant operating at speeds of 200,000 rpm did not increase bioaerosolization in the dental surgery. Thermal risk is variable, dependent on handpiece design and remaining dentine thickness
Optically trapped bacteria pairs reveal discrete motile response to control aggregation upon cell–cell approach
Aggregation of bacteria plays a key role in the formation of many biofilms. The critical first step is cell–cell approach, and yet the ability of bacteria to control the likelihood of aggregation during this primary phase is unknown. Here, we use optical tweezers to measure the force between isolated Bacillus subtilis cells during approach. As we move the bacteria towards each other, cell motility (bacterial swimming) initiates the generation of repulsive forces at bacterial separations of ~3 μm. Moreover, the motile response displays spatial sensitivity with greater cell–cell repulsion evident as inter-bacterial distances decrease. To examine the environmental influence on the inter-bacterial forces, we perform the experiment with bacteria suspended in Tryptic Soy Broth, NaCl solution and deionised water. Our experiments demonstrate that repulsive forces are strongest in systems that inhibit biofilm formation (Tryptic Soy Broth), while attractive forces are weak and rare, even in systems where biofilms develop (NaCl solution). These results reveal that bacteria are able to control the likelihood of aggregation during the approach phase through a discretely modulated motile response. Clearly, the force-generating motility we observe during approach promotes biofilm prevention, rather than biofilm formation
Mathematically gifted and talented learners: Theory and practice
This is an Author's Accepted Manuscript of an article published in International Journal of Mathematical Education in Science and Technology, 40(2), 213-228, 2009, copyright Taylor & Francis, available online at: http://www.tandfonline.com/10.1080/00207390802566907.There is growing recognition of the special needs of mathematically gifted learners. This article reviews policy developments and current research and theory on giftedness in mathematics. It includes a discussion of the nature of mathematical ability as well as the factors that make up giftedness in mathematics. The article is set in the context of current developments in Mathematics Education and Gifted Education in the UK and their implications for Science and Technology. It argues that early identification and appropriate provision for younger mathematically promising pupils capitalizes on an intellectual resource which could provide future mathematicans as well as specialists in Science or Technology. Drawing on a Vygotskian framework, it is suggested that the mathematically gifted require appropriate cognitive challenges as well as attitudinally and motivationally enhancing experiences. In the second half of this article we report on an initiative in which we worked with teachers to identify mathematically gifted pupils and to provide effective enrichment support for them, in a number of London Local Authorities. A number of significant issues are raised relating to the identification of mathematical talent, enrichment provision for students and teachers’ professional development
Does inter-vertebral range of motion increase after spinal manipulation? A prospective cohort study.
Background: Spinal manipulation for nonspecific neck pain is thought to work in part by improving inter-vertebral range of motion (IV-RoM), but it is difficult to measure this or determine whether it is related to clinical outcomes.
Objectives: This study undertook to determine whether cervical spine flexion and extension IV-RoM increases after a course of spinal manipulation, to explore relationships between any IV-RoM increases and clinical outcomes and to compare palpation with objective measurement in the detection of hypo-mobile segments.
Method: Thirty patients with nonspecific neck pain and 30 healthy controls matched for age and gender received quantitative fluoroscopy (QF) screenings to measure flexion and extension IV-RoM (C1-C6) at baseline and 4-week follow-up between September 2012-13. Patients received up to 12 neck manipulations and completed NRS, NDI
and Euroqol 5D-5L at baseline, plus PGIC and satisfaction questionnaires at follow-up. IV-RoM accuracy, repeatability and hypo-mobility cut-offs were determined. Minimal detectable changes (MDC) over 4 weeks were calculated
from controls. Patients and control IV-RoMs were compared at baseline as well as changes in patients over 4 weeks. Correlations between outcomes and the number of manipulations received and the agreement (Kappa) between palpated and QF-detected of hypo-mobile segments were calculated.
Results: QF had high accuracy (worst RMS error 0.5o) and repeatability (highest SEM 1.1o, lowest ICC 0.90) for
IV-RoM measurement. Hypo-mobility cut offs ranged from 0.8o to 3.5o. No outcome was significantly correlated with increased IV-RoM above MDC and there was no significant difference between the number of hypo-mobile segments in patients and controls at baseline or significant increases in IV-RoMs in patients. However, there was a modest and significant correlation between the number of manipulations received and the number of levels and directions whose IV-RoM increased beyond MDC (Rho=0.39, p=0.043). There was also no agreement between palpation and QF in identifying hypo-mobile segments (Kappa 0.04-0.06).
Conclusions: This study found no differences in cervical sagittal IV-RoM between patients with non-specific neck pain and matched controls. There was a modest dose-response relationship between the number of manipulations given and number of levels increasing IV-RoM - providing evidence that neck manipulation has a mechanical effect at segmental levels. However, patient-reported outcomes were not related to this
Neuromuscular Blockade with Rocuronium Bromide Increases the Tolerance of Acute Normovolemic Anemia in Anesthetized Pigs
Background: The patient's individual anemia tolerance is pivotal when blood transfusions become necessary, but are not feasible for some reason. To date, the effects of neuromuscular blockade (NMB) on anemia tolerance have not been investigated. Methods: 14 anesthetized and mechanically ventilated pigs were randomly assigned to the Roc group (3.78 mg/kg rocuronium bromide followed by continuous infusion of 1 mg/kg/min, n = 7) or to the Sal group (administration of the corresponding volume of normal saline, n = 7). Subsequently, acute normovolemic anemia was induced by simultaneous exchange of whole blood for a 6% hydroxyethyl starch solution (130/0.4) until a sudden decrease of total body O-2 consumption (VO2) indicated a critical limitation of O-2 transport capacity. The Hb concentration quantified at this time point (Hb(crit)) was the primary end-point of the protocol. Secondary endpoints were parameters of hemodynamics, O-2 transport and tissue oxygenation. Results: Hb(crit) was significantly lower in the Roc group (2.4 +/- 0.5 vs. 3.2 +/- 0.7 g/dl) reflecting increased anemia tolerance. NMB with rocuronium bromide reduced skeletal muscular VO2 and total body O-2 extraction rate. As the cardiac index increased simultaneously, total body VO2 only decreased marginally in the Roc group (change of VO2 relative to baseline -1.7 +/- 0.8 vs. 3.2 +/- 1.9% in the Sal group, p < 0.05). Conclusion: Deep NMB with rocuronium bromide increases the tolerance of acute normovolemic anemia. The underlying mechanism most likely involves a reduction of skeletal muscular VO2. During acellular treatment of an acute blood loss, NMB might play an adjuvant role in situations where profound stages of normovolemic anemia have to be tolerated (e.g. bridging an unexpected blood loss until blood products become available for transfusion). Copyright (C) 2011 S. Karger AG, Base
Systematic reviews of complementary therapies - an annotated bibliography. Part 1: Acupuncture
Background Complementary therapies are widespread but controversial. We aim to provide a comprehensive collection and a summary of systematic reviews of clinical trials in three major complementary therapies (acupuncture, herbal medicine, homeopathy). This article is dealing with acupuncture. Potentially relevant reviews were searched through the register of the Cochrane Complementary Medicine Field, the Cochrane Library, Medline, and bibliographies of articles and books. To be included articles had to review prospective clinical trials of acupuncture; had to describe review methods explicitly; had to be published; and had to focus on treatment effects. Information on conditions, interventions, methods, results and conclusions was extracted using a pretested form and summarized descriptively. Results From a total of 48 potentially relevant reviews preselected in a screeening process 39 met the inclusion criteria. 22 were on various pain syndromes or rheumatic diseases. Other topics addressed by more than one review were addiction, nausea, asthma and tinnitus. Almost unanimously the reviews state that acupuncture trials include too few patients. Often included trials are heterogeneous regarding patients, interventions and outcome measures, are considered to have insufficient quality and contradictory results. Convincing evidence is available only for postoperative nausea, for which acupuncture appears to be of benefit, and smoking cessation, where acupuncture is no more effective than sham acupuncture. Conclusions A large number of systematic reviews on acupuncture exists. What is most obvious from these reviews is the need for (the funding of) well-designed, larger clinical trials
Clinical Relevance and Discriminatory Value of Elevated Liver Aminotransferase Levels for Dengue Severity
Dengue is a global public health problem, as the incidence of the disease has reached hyperendemic proportions in recent decades. Infection with dengue can cause acute, febrile illness or severe disease, which can lead to plasma leakage, bleeding, and organ impairment. One of the most prominent clinical characteristics of dengue patients is increased aspartate and alanine aminotransferase liver enzyme levels. The significance of this is uncertain, as it is transient in the majority of cases, and most patients recover uneventfully without liver damage. In this study, we characterized this phenomenon in the context of dengue severity and found that, although liver enzyme levels increased concurrently with dengue severity, they could not sufficiently discriminate between dengue fever and dengue hemorrhagic fever or between non-severe and severe dengue. Therefore clinicians may need to use other parameters to distinguish dengue severity in patients during early illness
Treatment options for subjective tinnitus: Self reports from a sample of general practitioners and ENT physicians within Europe and the USA
<p>Abstract</p> <p>Background</p> <p>Tinnitus affects about 10-15% of the general population and risks for developing tinnitus are rising through increased exposure to leisure noise through listening to personal music players at high volume. The disorder has a considerable heterogeneity and so no single mechanism is likely to explain the presence of tinnitus in all those affected. As such there is no standardized management pathway nor singly effective treatment for the condition. Choice of clinical intervention is a multi-factorial decision based on many factors, including assessment of patient needs and the healthcare context. The present research surveyed clinicians working in six Westernized countries with the aims: a) to establish the range of referral pathways, b) to evaluate the typical treatment options for categories of subjective tinnitus defined as acute or chronic, and c) to seek clinical opinion about levels of satisfaction with current standards of practice.</p> <p>Methods</p> <p>A structured online questionnaire was conducted with 712 physicians who reported seeing at least one tinnitus patients in the previous three months. They were 370 general practitioners (GPs) and 365 ear-nose-throat specialists (ENTs) from the US, Germany, UK, France, Italy and Spain.</p> <p>Results</p> <p>Our international comparison of health systems for tinnitus revealed that although the characteristics of tinnitus appeared broadly similar across countries, the patient's experience of clinical services differed widely. GPs and ENTs were always involved in referral and management to some degree, but multi-disciplinary teams engaged either neurology (Germany, Italy and Spain) or audiology (UK and US) professionals. For acute subjective tinnitus, pharmacological prescriptions were common, while audiological and psychological approaches were more typical for chronic subjective tinnitus; with several specific treatment options being highly country specific. All therapy options were associated with low levels of satisfaction.</p> <p>Conclusions</p> <p>Despite a large variety of treatment options, the low success rates of tinnitus therapy lead to frustration of physicians and patients alike. For subjective tinnitus in particular, effective therapeutic options with guidelines about key diagnostic criteria are urgently needed.</p
Three dimensional evaluation of posture in standing with the PosturePrint: an intra- and inter-examiner reliability study
Abstract Background Few digitizers can measure the complexity of upright human postural displacements in six degrees of freedom of the head, rib cage, and pelvis. Methods In a University laboratory, three examiners performed delayed repeated postural measurements on forty subjects over two days. Three digital photographs (left lateral, AP, right lateral) of each of 40 volunteer participants were obtained, twice, by three examiners. Examiners placed 13 markers on the subjects before photography and chose 16 points on the photographic images. Using the PosturePrint® internet computer system, head, rib cage, and pelvic postures were calculated as rotations (Rx, Ry, Rz) in degrees and translations (Tx, Tz) in millimeters. For reliability, two different types (liberal = ICC3,1 & conservative = ICC2,1) of inter- and intra-examiner correlation coefficients (ICC) were calculated. Standard error of measurements (SEM) and mean absolute differences within and between observers' measurements were also determined. Results All of the "liberal" ICCs were in the excellent range (> 0.84). For the more "conservative" type ICCs, four Inter-examiner ICCs were in the interval (0.5–0.6), 10 ICCs were in the interval (0.61–0.74), and the remainder were greater than 0.75. SEMs were 2.7° or less for all rotations and 5.9 mm or less for all translations. Mean absolute differences within examiners and between examiners were 3.5° or less for all rotations and 8.4 mm or less for all translations. Conclusion For the PosturePrint® system, the combined inter-examiner and intra-examiner correlation coefficients were in the good (14/44) and excellent (30/44) ranges. SEMs and mean absolute differences within and between examiners' measurements were small. Thus, this posture digitizer is reliable for clinical use
- …