6 research outputs found

    The European TeleCheck-AF project on remote app-based management of atrial fibrillation during the COVID-19 pandemic: Centre and patient experiences

    Get PDF
    Aims: TeleCheck-AF is a multicentre international project initiated to maintain care delivery for patients with atrial fibrillation (AF) during COVID-19 through teleconsultations supported by an on-demand photoplethysmography-based heart rate and rhythm monitoring app (FibriCheck® ). We describe the characteristics, inclusion rates and experiences from participating centres according the TeleCheck-AF infrastructure as well as characteristics and experiences from recruited patients.Methods: Three surveys exploring centre characteristics (n=25), centre experiences (n=23) and patient experiences (n=826) were completed. Self-reported patient characteristics were obtained from the app.Results: Most centres were academic (64%) and specialized public cardiology/district hospitals (36%). Majority of centres had AF outpatient clinics (64%) and only 36% had AF ablation clinics. The time required to start patient inclusion and total number of included patients in the project was comparable for centres experienced (56%) or inexperienced in mHealth use. Within 28 weeks, 1930 AF patients were recruited, mainly for remote AF control (31% of patients) and AF ablation follow-up (42%). Average inclusion rate was highest during the lockdown restrictions and reached a steady state at a lower level after easing the restrictions (188 vs 52 weekly recruited patients). Majority (>80%) of the centres reported no problems during the implementation of the TeleCheck-AF approach. Recruited patients (median age 64 [55-71], 62% male) agreed that the FibriCheck® app was easy to use (94%).Conclusions: Despite different health care settings and mHealth experiences, the TeleCheck-AF approach could be set up within an extremely short time and easily used in different European centres during COVID-19

    Repurposing catheter ablation work-up to detect expiratory airflow limitation in patients with atrial fibrillation

    No full text
    Background: In atrial fibrillation (AF) patients, presence of expiratory airflow limitation may negatively impact treatment outcomes. AF patients are not routinely screened for expiratory airflow limitation, but existing examinations can help identify at-risk individuals. We aimed to assess the diagnostic value of repurposing existing assessments from the pre-ablation work-up to identify and understand the characteristics of affected patients. Methods: We screened 110 consecutive AF patients scheduled for catheter ablation with handheld spirometry. Routine pre-ablation work-up included cardiac computed tomographic angiography (CCTA), transthoracic echocardiography and polygraphy. CCTA was analyzed qualitatively for emphysema and airway abnormalities. Multivariate logistic regression analysis was performed to determine predictors of expiratory airflow limitation. Results: We found that 25 % of patients had expiratory airflow limitation, which was undiagnosed in 86 % of these patients. These patients were more likely to have pulmonary abnormalities on CCTA, including emphysema (odds ratio [OR] 4.2, 95 % confidence interval [CI] 1.12–15.1, p < 0.05) and bronchial wall thickening (OR 2.6, 95 % CI 1.0–6.5, p < 0.05). The absence of pulmonary abnormalities on CCTA accurately distinguished patients with normal lung function from those with airflow limitation (negative predictive value: 85 %). Echocardiography and polygraphy did not contribute significantly to identifying airflow limitation. Conclusions: In conclusion, routine pre-ablation CCTA can detect pulmonary abnormalities in AF patients with airflow limitation, guiding further pulmonary assessment. Future studies should investigate its impact on ablation procedure success

    Patient motivation and adherence to an on-demand app-based heart rate and rhythm monitoring for atrial fibrillation management : data from the TeleCheck-AF project

    Get PDF
    AIMS: The aim of this TeleCheck-AF sub-analysis was to evaluate motivation and adherence to on-demand heart rate/rhythm monitoring app in patients with atrial fibrillation (AF). METHODS AND RESULTS: Patients were instructed to perform 60 s app-based heart rate/rhythm recordings 3 times daily and in case of symptoms for 7 consecutive days prior to teleconsultation. Motivation was defined as number of days in which the expected number of measurements (≥3/day) were performed per number of days over the entire prescription period. Adherence was defined as number of performed measurements per number of expected measurements over the entire prescription period.Data from 990 consecutive patients with diagnosed AF [median age 64 (57-71) years, 39% female] from 10 centres were analyzed. Patients with both optimal motivation (100%) and adherence (≥100%) constituted 28% of the study population and had a lower percentage of recordings in sinus rhythm [90 (53-100%) vs. 100 (64-100%), P < 0.001] compared with others. Older age and absence of diabetes were predictors of both optimal motivation and adherence [odds ratio (OR) 1.02, 95% coincidence interval (95% CI): 1.01-1.04, P < 0.001 and OR: 0.49, 95% CI: 0.28-0.86, P = 0.013, respectively]. Patients with 100% motivation also had ≥100% adherence. Independent predictors for optimal adherence alone were older age (OR: 1.02, 95% CI: 1.00-1.04, P = 0.014), female sex (OR: 1.70, 95% CI: 1.29-2.23, P < 0.001), previous AF ablation (OR: 1.35, 95% CI: 1.03-1.07, P = 0.028). CONCLUSION: In the TeleCheck-AF project, more than one-fourth of patients had optimal motivation and adherence to app-based heart rate/rhythm monitoring. Older age and absence of diabetes were predictors of optimal motivation/adherence
    corecore