10 research outputs found
Questionario europeo di consenso sui reimpianti di arto superiore
Questionario europeo di consenso sui reimpianti di arto superiore
Potenziali rischi per un eccesso di igiene in casa.Potential risks from an excess of hygienic cleaning in the domestic setting
The most relevant and recent risks associated with an excessive hygiene are here presented. Besides general observations on the relationship between hygiene and immune system, we discuss possible acute and chronic effects due to home exposure to detergents. The specific problem of hygienic cleaning introduced on a vaste scale at home requires the comparison with similar experiences in the hospitals,, evaluation of efficacy, comprhension of risks such as the selection of resistant micro-organisms
La legionellosi come problema emergente di SanitĂ Pubblica: aspetti di sorveglianza, diagnosi e controllo ambientale alla luce di recenti esperienze ospedaliere
La malattia dei legionari è un problema ubiquitario, che interessa non solo il personale medico ospedaliero ma anche i medici operanti sul territorio, considerato che la maggior parte dei casi ha un'origine comunitaria, anche se i casi nosocomiali destano maggiore preoccupazione per la gravità .In questo studio vengono riportate le esperienze di due ospedali del Nord Italia sulla identificazione e sul controllo della legionellosi
The discharge form: advantages and limits legionellosis cases individuation
Despite legionellosis surveillance is active in Italy since many years, the disease notification appears still undervalued. A multicentric survey was carried out among 5 big Italian hospitals. It examined 11,435 discharge forms (1999-2001), reporting pneumonia diagnosis. Legionellosis (II class of notify system for infectious disease) was studied among pneumonia diagnosis by discharge forms. According to the ICD9-CM, there's no specific code for legionellosis (this disease is included among "others gram-negative pneumonia"). So the presumed pneumonia imputable to Legionella spp were the 2.7% of the whole number of analyzed discharge forms. Besides, the data regarding the other pneumonia showed that the etiological agent was specified only in the 11.2% of the case. This situation could be rectified both introducing adequate discharge forms codes and promoting the etiological diagnosis during the hospital sta
[The discharge form: advantages and limits legionellosis cases individuation]
Despite legionellosis surveillance is active in Italy since many years, the disease notification appears still undervalued. A multicentric survey was carried out among 5 big Italian hospitals. It examined 11,435 discharge forms (1999-2001), reporting pneumonia diagnosis. Legionellosis (II class of notify system for infectious disease) was studied among pneumonia diagnosis by discharge forms. According to the ICD9-CM, there's no specific code for legionellosis (this disease is included among "others gram-negative pneumonia"). So the presumed pneumonia imputable to Legionella spp were the 2.7% of the whole number of analyzed discharge forms. Besides, the data regarding the other pneumonia showed that the etiological agent was specified only in the 11.2% of the case. This situation could be rectified both introducing adequate discharge forms codes and promoting the etiological diagnosis during the hospital stay
[Environmental diffusion of Legionella spp and legionellosis frequency among patients with pneumonia: preliminary results of a multicentric Italian survey]
A multicentric Italian investigation on legionnaires' disease is in course to clarify host factors as well as pathogen associated characteristics involved in the infection/disease. The main goal of the research plan is to account for some critical aspects concerning identification and prevention of legionellosis. To improve knowledge on factors associated with Legionella spp colonisation in hot waters, to detect cases and to characterize risk factors in subjects which develop pneumonia are specific objectives of the research programme. Preliminary results show that hot waters of houses and hotels are frequently contaminated (22.6% and 54.6%, respectively), mainly by L. pneumophila. Microbial concentrations were low in domestic waters (<1.000 ufc/l), but higher in samples from the hotels (geom. mean 1.85 x 10(3) ufc/l). Warming system, age of the plant, type of building were risk factors significantly associated with Legionella spp positivity. The active surveillance on patients affected by pneumonia with search for Legionella urinary antigen allowed the identification of 34 cases, 3 of which of nosocomial origin, corresponding to 4.2% of the screened pneumonia. After informed consent, 26 subjects were recruited for a case-control-study to clarify risk factors for the disease
Diffusione ambientale di Legionella spp e frequenza di legionellosi in pazienti affetti da polmonite: primi risultati di uno studio multicentrico italiano
A multicentric Italian investigation on legionnaires' disease is in course to clarify host factors as well as pathogen associated characteristics involved in the infection/disease. The main goal of the research plan is to account for some critical aspects concerning identification and prevention of legionellosis. To improve knowledge on factors associated with Legionella spp colonisation in hot waters, to detect cases and to characterize risk factors in subjects which develop pneumonia are specific objectives of the research programme. Preliminary results show that hot waters of houses and hotels are frequently contaminated (22.6% and 54.6%, respectively), mainly by L. pneumophila. Microbial concentrations were low in domestic waters (<1.000 ufc/l), but higher in samples from the hotels (geom. mean 1.85 x 10(3) ufc/l). Warming system, age of the plant, type of building were risk factors significantly associated with Legionella spp positivity. The active surveillance on patients affected by pneumonia with search for Legionella urinary antigen allowed the identification of 34 cases, 3 of which of nosocomial origin, corresponding to 4.2% of the screened pneumonia. After informed consent, 26 subjects were recruited for a case-control-study to clarify risk factors for the disease
Diffusione ambientale di Legionella spp e frequenza di legionellosi in pazienti affetti da polmonite: primi risultati di uno studio multicentrico italiano
A multicentric Italian investigation on legionnaires' disease is in course to clarify host factors as well as pathogen associated characteristics involved in the infection/disease. The main goal of the research plan is to account for some critical aspects concerning identification and prevention of legionellosis. To improve knowledge on factors associated with Legionella spp colonisation in hot waters, to detect cases and to characterize risk factors in subjects which develop pneumonia are specific objectives of the research programme. Preliminary results show that hot waters of houses and hotels are frequently contaminated (22.6% and 54.6%, respectively), mainly by L. pneumophila. Microbial concentrations were low in domestic waters (<1.000 ufc/l), but higher in samples from the hotels (geom. mean 1.85 x 10(3) ufc/l). Warming system, age of the plant, type of building were risk factors significantly associated with Legionella spp positivity. The active surveillance on patients affected by pneumonia with search for Legionella urinary antigen allowed the identification of 34 cases, 3 of which of nosocomial origin, corresponding to 4.2% of the screened pneumonia. After informed consent, 26 subjects were recruited for a case-control-study to clarify risk factors for the disease