14 research outputs found

    Imunofluorescência para diagnóstico de herpes oftálmico usando como modelo córneas de camundongos infectados

    Get PDF
    Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.A doença oftálmica do vírus herpes simplex do tipo 1 (HSV-1) é a causa mais comum de cegueira córnea em humanos mundialmente. Técnicas de cultura atuais para HSV levam vários dias e laboratórios de HSV comercialmente disponíveis estabelecem que as técnicas diagnósticas variam em sensibilidade. Nosso estudo foi conduzido para avaliar a aplicação prática de um método mais rápido e simples para diagnosticar o herpes oftálmico. Decalques córneos foram feitos por impressões firmes de olhos de camundongos a lâminas de vidro, depois os decalques foram fixados com acetona fria, e um método de imunofluorescência indireta (IIF) foi executado empregando anticorpos monoclonais no modelo murino de herpes oftálmico. Swabs de córnea foram inoculados em células Vero para o isolamento de vírus a partir de camundongos infectados. A citologia e a histologia do olho foi feita pela rotina de hematoxilina e eosina. Os olhos de camundongos foram examinados através de oftalmomicroscopia para evidência de doença herpética em vários tempos pós-inoculação. A avaliação comparativa da sensibilidade, especificidade e velocidade de métodos para detecção laboratorial de HSV foi feita. Nossos resultados indicam que este método de IIF é rápido, sensível, específico e pode ser útil no diagnóstico de herpes oftálmico como demonstrado no modelo animal

    Atividade da catalase no pulmão, rim e intestino delgado não isquemiado de ratos após reperfusão intestinal

    No full text
    OBJETIVO: Avaliar a atividade catalase, após lesão por isquemia e reperfusão intestinal e estudar as alterações deste antioxidante em órgãos situados à distância do insulto inicial. MÉTODOS: Utilizaram-se 18 ratos do tipo Wistar, aleatoriamente distribuídos em três grupos. 1-Controle, 2-Simulação e 3-Isquemia/Reperfusão. Neste último, realizou-se isquemia no íleo, por 60 minutos, seguida de reperfusão por 30 minutos. No grupo 2 efetuou-se apenas uma laparotomia. Foram retirados, de todos os animais, segmentos do intestino com e sem reperfusão, além do pulmão e rim direitos para exame com microscopia óptica. A atividade da catalase foi aferida em espectrofotômetro ajustado para 240 nm. Utilizaram-se os testes estatísticos Mann e Whitney e Kruskal Wallis. RESULTADOS: Observou-se aumento significante (p < 0.05), da atividade da catalase nas porções do intestino isquemiado e não isquemiado, além do pulmão. Houve redução da atividade enzimática no rim. No grupo com reperfusão observaram-se alteração nas vilosidades, infiltrado inflamatório em todas as vísceras, além de áreas de atelectasia pulmonar. CONCLUSÃO: O estresse oxidativo intestinal, em ratos, causa alterações bioquímicas à distância com mobilização dos mecanismos de defesa antioxidante pulmonar, em segmento intestinal não isquemiado e no rim, com esgotamento precoce das reservas deste último, no entanto, sem lesão celular relevante, destas vísceras

    Nonwoven polypropylene prosthesis in large abdominal wall defects in rats Tela de polipropileno sem tecelagem na correção de grandes defeitos da parede abdominal em ratos

    No full text
    PURPOSE: To evaluate, in large abdominal wall defects surgically shaped in rats, if a synthetic polypropylene nonwoven prosthesis could be used as a therapeutic option to conventional polypropylene mesh. METHODS: Twenty four (24) Wistar rats were enrolled into three groups. Group 1 (Simulation group) with an abdominal wall defect of 3 X 3 left untreated and Groups 2 and 3, respectively treated with a conventional polypropylene mesh and a polypropylene nonwoven (NWV) prosthesis to cover the breach. At the 45th postoperatively day, adhesion (area and strength) and vascularization of Groups 2 and 3 were evaluated. The histological preparations with Hematoxylin-Eosin, Tricromium of Masson, Pricrosirius red and polarization with birefringence, and also the structural analysis of the prostheses carried on by Thermogravimetry and Differential Scanning Calorimetry were also assessed. RESULTS: There were no significant differences between the Groups 2 and 3. CONCLUSION: In rats, the polypropylene nonwoven prosthesis showed to be safe and has to be considered as an alternative to conventional mesh manufactured by weaving in the treatment of great defects of the abdominal wall.<br>OBJETIVO: Avaliar, em grandes defeitos da parede abdominal produzidos cirurgicamente em ratos, se uma prótese sintética de polipropileno sem tecelagem poderia ser utilizada como alternativa terapêutica às telas convencionais de polipropileno. MÉTODOS: Vinte e quatro ratos foram distribuídos em três grupos numericamente iguais. Grupo 1 (Simulação), no qual um defeito de 3 x 3 cm foi constituído na parede abdominal sem tratamento. Uma tela convencional de polipropileno e uma tela de polipropileno sem tecelagem foram colocadas para cobrir o defeito, nos grupos 2 e 3 , respectivamente. No 45º dia de pós-operatório foram avaliadas a área e a força das aderências, além da vascularização. Também foram analisados os preparados histológicos com Hematoxilina-eosina, Tricrômio de Masson e Picrosirius com polarização e birrefringência, além de efetuada análise estrutural da prótese mediante Termogavimetria e Colorimetria Exploratória Diferencial. RESULTADOS: Não houve diferença significante entre os grupos 2 e 3. CONCLUSÃO: Em ratos, a tela de polipropileno sem tecelagem mostrou ser segura e deve ser considerada como uma alternativa à tela convencional manufaturada por tecelagem, no tratamento dos grandes defeitos da parede abdominal

    Embolização pré operatória de tumores renais com microparticulas esféricas de tecnologia nacional. (Spherus®-First line Brasil)

    No full text
    Os autores relatam pela primeira vez utilização de uma nova partícula para embolização, constituída de um núcleo de acetato de polivinil revestido por polivinil-álcool, de forma esférica (Spherus®-First Line Brasil), como preparo pré-operatório em três pacientes portadores de neoplasia renal, na intenção de diminuir o tamanho do tumor e prevenir complicações hemorrágicas durante o ato operatório. Estas novas partículas foram projetadas e elaboradas nos laboratórios da COPPE/UFRJ. A embolização intra-arterial pré-operatória com estas novas partículas ocasionou acentuada isquemia em todo o tecido tumoral facilitando o procedimento cirúrgico

    Embolização intra-arterial pré-operatória de tumor do corpo carotídeo Preoperative intraarterial embolization of carotid body tumor

    No full text
    Os autores relatam um caso de tumor de corpo carotídeo (paraganglioma) em um paciente de 74 anos de idade, submetido a embolização intra-arterial com micropartículas esféricas, de polivinil acetato, com casca de polivinil álcool (PVAc + PVA), previamente à ressecção do tumor. O estudo angiográfico demonstrou massa altamente vascularizada na bifurcação carotídea esquerda, sendo a embolização pré-operatória utilizada no intuito de diminuir a vascularização e reduzir a perda sangüínea, aumentando a segurança do tratamento cirúrgico. O estudo histopatológico confirmou a presença de trombose e isquemia tecidual.<br>The authors report a case of carotid body tumor (paraganglioma) in a 74-year-old male patient, submitted to intraarterial embolization with spherical core/shield polyvinyl acetate and polyvinyl alcohol (PVAc + PVA) microparticles prior to surgical excision. Angiography has demonstrated a highly vascularized mass in the left carotid bifurcation, and preoperative embolization was used in order to decrease vascularity, reduce blood loss and improve safety of surgical treatment. Microscopic study confirmed presence of thrombosis and tissue ischemia
    corecore