61 research outputs found

    Photometric redshifts for the Kilo-Degree Survey. Machine-learning analysis with artificial neural networks

    Get PDF
    We present a machine-learning photometric redshift analysis of the Kilo-Degree Survey Data Release 3, using two neural-network based techniques: ANNz2 and MLPQNA. Despite limited coverage of spectroscopic training sets, these ML codes provide photo-zs of quality comparable to, if not better than, those from the BPZ code, at least up to zphot<0.9 and r<23.5. At the bright end of r<20, where very complete spectroscopic data overlapping with KiDS are available, the performance of the ML photo-zs clearly surpasses that of BPZ, currently the primary photo-z method for KiDS. Using the Galaxy And Mass Assembly (GAMA) spectroscopic survey as calibration, we furthermore study how photo-zs improve for bright sources when photometric parameters additional to magnitudes are included in the photo-z derivation, as well as when VIKING and WISE infrared bands are added. While the fiducial four-band ugri setup gives a photo-z bias δz=2e4\delta z=-2e-4 and scatter σz<0.022\sigma_z<0.022 at mean z = 0.23, combining magnitudes, colours, and galaxy sizes reduces the scatter by ~7% and the bias by an order of magnitude. Once the ugri and IR magnitudes are joined into 12-band photometry spanning up to 12 μ\mu, the scatter decreases by more than 10% over the fiducial case. Finally, using the 12 bands together with optical colours and linear sizes gives δz<4e5\delta z<4e-5 and σz<0.019\sigma_z<0.019. This paper also serves as a reference for two public photo-z catalogues accompanying KiDS DR3, both obtained using the ANNz2 code. The first one, of general purpose, includes all the 39 million KiDS sources with four-band ugri measurements in DR3. The second dataset, optimized for low-redshift studies such as galaxy-galaxy lensing, is limited to r<20, and provides photo-zs of much better quality than in the full-depth case thanks to incorporating optical magnitudes, colours, and sizes in the GAMA-calibrated photo-z derivation.Comment: A&A, in press. Data available from the KiDS website http://kids.strw.leidenuniv.nl/DR3/ml-photoz.php#annz

    Field Intercomparison of Radiometer Measurements for Ocean Colour Validation

    Get PDF
    A field intercomparison was conducted at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea, from 9 to 19 July 2018 to assess differences in the accuracy of in- and above-water radiometer measurements used for the validation of ocean colour products. Ten measurement systems were compared. Prior to the intercomparison, the absolute radiometric calibration of all sensors was carried out using the same standards and methods at the same reference laboratory. Measurements were performed under clear sky conditions, relatively low sun zenith angles, moderately low sea state and on the same deployment platform and frame (except in-water systems). The weighted average of five above-water measurements was used as baseline reference for comparisons. For downwelling irradiance (), there was generally good agreement between sensors with differences of <6% for most of the sensors over the spectral range 400 nm–665 nm. One sensor exhibited a systematic bias, of up to 11%, due to poor cosine response. For sky radiance () the spectrally averaged difference between optical systems was <2.5% with a root mean square error (RMS) <0.01 mWm−2 nm−1 sr−1. For total above-water upwelling radiance (), the difference was <3.5% with an RMS <0.009 mWm−2 nm−1 sr−1. For remote-sensing reflectance (), the differences between above-water TriOS RAMSES were <3.5% and <2.5% at 443 and 560 nm, respectively, and were <7.5% for some systems at 665 nm. Seabird HyperSAS sensors were on average within 3.5% at 443 nm, 1% at 560 nm, and 3% at 665 nm. The differences between the weighted mean of the above-water and in-water systems was <15.8% across visible bands. A sensitivity analysis showed that accounted for the largest fraction of the variance in , which suggests that minimizing the errors arising from this measurement is the most important variable in reducing the inter-group differences in . The differences may also be due, in part, to using five of the above-water systems as a reference. To avoid this, in situ normalized water-leaving radiance () was therefore compared to AERONET-OC SeaPRiSM as an alternative reference measurement. For the TriOS-RAMSES and Seabird-Hyperspectral Surface Acquisition System (HyperSAS) sensors the differences were similar across the visible spectra with 4.7% and 4.9%, respectively. The difference between SeaPRiSM and two in-water systems at blue, green and red bands was 11.8%. This was partly due to temporal and spatial differences in sampling between the in-water and above-water systems and possibly due to uncertainties in instrument self-shading for one of the in-water measurements

    Sex and Gender Differences in Ischemic Heart Disease: Endocrine Vascular Disease Approach (EVA) Study Design

    Get PDF
    Improvements in ischemic heart disease (IHD) management have been unbalanced between sexes, with coronary microvascular dysfunction considered the likely underlying reason. The Endocrine Vascular disease Approach (EVA) is an observational study (Clinicaltrial.gov NCT02737982) aiming to assess sex and gender interactions between coronary circulation, sexual hormones, and platelet function. Consecutive patients with IHD undergoing coronary angiography will be recruited: (1) to assess sex and gender differences in angiographic reperfusion indexes; (2) to evaluate the effects of estrogen/androgen on sex-related differences in myocardial ischemia; (3) to investigate the platelet biology differences between men and women with IHD; (4) to verify sex- and gender-driven interplay between response to percutaneous coronary intervention, platelets, sex hormones, and myocardial damage at baseline and its impact on 12-month outcomes. The integration of sex and gender in this translational project on IHD will contribute to the identification of new targets for further innovative clinical interventions

    Personalizing Cancer Pain Therapy: Insights from the Rational Use of Analgesics (RUA) Group

    Get PDF
    Introduction: A previous Delphi survey from the Rational Use of Analgesics (RUA) project involving Italian palliative care specialists revealed some discrepancies between current guidelines and clinical practice with a lack of consensus on items regarding the use of strong opioids in treating cancer pain. Those results represented the basis for a new Delphi study addressing a better approach to pain treatment in patients with cancer. Methods: The study consisted of a two-round multidisciplinary Delphi study. Specialists rated their agreement with a set of 17 statements using a 5-point Likert scale (0 = totally disagree and 4 = totally agree). Consensus on a statement was achieved if the median consensus score (MCS) (expressed as value at which at least 50% of participants agreed) was at least 4 and the interquartile range (IQR) was 3–4. Results: This survey included input from 186 palliative care specialists representing all Italian territory. Consensus was reached on seven statements. More than 70% of participants agreed with the use of low dose of strong opioids in moderate pain treatment and valued transdermal route as an effective option when the oral route is not available. There was strong consensus on the importance of knowing opioid pharmacokinetics for therapy personalization and on identifying immediate-release opioids as key for tailoring therapy to patients’ needs. Limited agreement was reached on items regarding breakthrough pain and the management of opioid-induced bowel dysfunction. Conclusion: These findings may assist clinicians in applying clinical evidence to routine care settings and call for a reappraisal of current pain treatment recommendations with the final aim of optimizing the clinical use of strong opioids in patients with cancer

    DTT - Divertor Tokamak Test facility: A testbed for DEMO

    Get PDF
    The effective treatment of the heat and power exhaust is a critical issue in the road map to the realization of the fusion energy. In order to provide possible, reliable, well assessed and on-time answers to DEMO, the Divertor Tokamak Test facility (DTT) has been conceived and projected to be carried out and operated within the European strategy in fusion technology. This paper, based on the invited plenary talk at the 31st virtual SOFT Conference 2020, provides an overview of the DTT scientific proposal, which is deeply illustrated in the 2019 DTT Interim Design Report

    DTT - Divertor Tokamak Test facility - Interim Design Report

    Get PDF
    The “Divertor Tokamak Test facility, DTT” is a milestone along the international program aimed at demonstrating – in the second half of this century – the feasibility of obtaining to commercial electricity from controlled thermonuclear fusion. DTT is a Tokamak conceived and designed in Italy with a broad international vision. The construction will be carried out in the ENEA Frascati site, mainly supported by national funds, complemented by EUROfusion and European incentive schemes for innovative investments. The project team includes more than 180 high-standard researchers from ENEA, CREATE, CNR, INFN, RFX and various universities. The volume, entitled DTT Interim Design Report (“Green Book” from the colour of the cover), briefly describes the status of the project, the planning of the design future activities and its organizational structure. The publication of the Green Book also provides an occasion for thorough discussions in the fusion community and a broad international collaboration on the DTT challenge

    Aggression, anxiety and vocalizations in animals: GABA A and 5-HT anxiolytics

    Full text link
    A continuing challenge for preclinical research on anxiolytic drugs is to capture the affective dimension that characterizes anxiety and aggression, either in their adaptive forms or when they become of clinical concern. Experimental protocols for the preclinical study of anxiolytic drugs typically involve the suppression of conditioned or unconditioned social and exploratory behavior (e.g., punished drinking or social interactions) and demonstrate the reversal of this behavioral suppression by drugs acting on the benzodiazepine-GABA A complex. Less frequently, aversive events engender increases in conditioned or unconditioned behavior that are reversed by anxiolytic drugs (e.g., fear-potentiated startle). More recently, putative anxiolytics which target 5-HT receptor subtypes produced effects in these traditional protocols that often are not systematic and robust. We propose ethological studies of vocal expressions in rodents and primates during social confrontations, separation from social companions, or exposure to aversive environmental events as promising sources of information on the affective features of behavior. This approach focusses on vocal and other display behavior with clear functional validity and homology. Drugs with anxiolytic effects that act on the benzodiazepine-GABA A receptor complex and on 5-HT 1A receptors systematically and potently alter specific vocalizations in rodents and primates in a pharmacologically reversible manner; the specificity of these effects on vocalizations is evident due to the effectiveness of low doses that do not compromise other physiological and behavioral processes. Antagonists at the benzodiazepine receptor reverse the effects of full agonists on vocalizations, particularly when these occur in threatening, startling and distressing contexts. With the development of antagonists at 5-HT receptor subtypes, it can be anticipated that similar receptor-specificity can be established for the effects of 5-HT anxiolytics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46351/1/213_2005_Article_BF02245590.pd

    Carbon black assisted tailoring of Prussian Blue nanoparticles to tune sensitivity and detection limit towards H2O2 by using screen-printed electrode

    No full text
    The development and characterization of screen-printed electrodes (SPEs) modified with nanocomposites formed by Prussian Blue nanoparticles (PBNPs) and carbon black (CB) for hydrogen peroxide detection are reported. SPEs were modified with PBNPs in several ways: i) by in situ PBNPs chemical deposition on SPEs previously modified with CB dispersion (bilayer), ii) by in situ PBNPs chemical deposition on SPEs prepared with graphite-ink containing CB, and iii) by casting SPEs with a CB/PBNPs dispersion. The use of chemical deposition on SPEs modified with CB in different manners allowed obtaining diverse dimensions of PBNPs, reflected in different analytical properties. The SPEs prepared with CB/PBNPs dispersion, characterized by PBNPs with an average diameter of 19 ± 3 nm, gave the best analytical performance in terms of detection limit (0.3 μM), while the SPEs modified with a bilayer of CB and PBNPs, characterized by PBNPs with an average diameter of 138 ± 15 nm, showed higher sensitivity but higher detection limit. We demonstrated that in using different substrates (graphite ink, graphite ink modified with 10% (w/w) with CB, bilayer graphite ink/CB, CB dispersion) we are able i) to produce CB-SPEs tailored with different sized PBNPs and ii) to tune the analytical performances towards hydrogen peroxide
    corecore