    Safety and treatment volumes achieved following new developments of the magnetic resonance-guided focused ultrasound system in the treatment of uterine fibroids: a cohort study.

    Get PDF
    BACKGROUND: This research investigates whether modifications to the magnetic resonance-guided focused ultrasound ablation of uterine fibroid (MRgFUS) system used resulted in improved treatment volumes of uterine fibroids, while maintaining safety. METHODS: This study is a prospective cohort analysis of 34 women undergoing the ExAblate 2100 MRgFUS treatment for their uterine fibroids. RESULTS: The percentage of non-perfused volume (NPV) achieved with the ExAblate 2100 system was 54.92% compared with 50.49 % with the ExAblate 2000 system over the preceding year (p = 0.543). The ExAblate 2100 system resulted in a greater NPV in hyper-intense fibroids compared with the ExAblate 200 system (43.20% versus 36.33%, p = 0.005). There have been no recorded hospital admissions, no skins burns, and no reported major adverse events since the introduction of this new system. CONCLUSION: Overall, the new system has thus far shown an encouraging safety record and an improvement in non-perfused volumes achieved, especially in hyper-intense fibroids

    Fricke and polymer gel 2D dosimetry validation using Monte Carlo simulation

    Get PDF
    Complexity in modern radiotherapy treatments demands advanced dosimetry systems for quality control. These systems must have several characteristics, such as high spatial resolution, tissue equivalence, three-dimensional resolution, and dose-integrating capabilities. In this scenario, gel dosimetry has proved to be a very promising option for quality assurance. In this study, the feasibility of Fricke and polymer gel dosimeters suitably shaped in form of thin layers and optically analyzed by visible light transmission imaging has been investigated for quality assurance in external radiotherapy. Dosimeter irradiation was carried out with a 6-MV photon beam (CLINAC 600C). The analysis of the irradiated dosimeters was done using two-dimensional optical transmission images. These dosimeters were compared with a treatment plan system using Monte Carlo simulations as a reference by means of a gamma test with parameters of 1 mm and 2%. Results show very good agreement between the different dosimetric systems: in the worst-case scenario, 98% of the analyzed points meet the test quality requirements. Therefore, gel dosimetry may be considered as a potential tool for the validation of other dosimetric systems.Fil: Vedelago, José Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad Nacional de Córdoba; ArgentinaFil: Chacón Obando, D.. Universidad Nacional. Physics Department; Costa Rica. Universidad Nacional de Córdoba; ArgentinaFil: Malano, Francisco Mauricio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad Nacional de Córdoba; ArgentinaFil: Conejeros, R.. Servicio de Radioterapia, Icos. Temuco, Chile;Fil: Figueroa, R.. Universidad de la Frontera; ChileFil: Garcia, D.. Servicio de Imagenes por Resonancia Magnética; ChileFil: González, G.. Servicio de Imagenes por Resonancia Magnética; ChileFil: Romero, Marcelo Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; Argentina. Universidad Nacional de Córdoba; ArgentinaFil: Santibañez, M.. Servicio de Imagenes por Resonancia Magnética; ChileFil: Strumia, Miriam Cristina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; ArgentinaFil: Velásquez, J.. Servicio de Radioterapia; ChileFil: Mattea, Facundo. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Departamento de Química Orgánica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Valente, M.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad de La Frontera. Departamento de Ciencias Físicas; Chil

    Ensayo Estructural No Destructivo Utilizando Microtomografía de Rayos X para Estimación de Diferencias de Densidad Másica en Muestras Óseas de Conejo

    Get PDF
    Al realizarse estudios sobre muestras óseas para analizar características como dureza, densidad y salud, se suelen utilizar equipamientos que permiten la cuantificación de la densidad electrónica, proporcional a la densidad másica, que se relaciona directamente con la densidad mineral ósea. El test conocido como densitometría ósea se suele realizar con equipos de rayos X, ultrasonido o por medio de la utilización de isótopos radioactivos. Este estudio cuantifica la cantidad mineral ósea por superficie y suele ser utilizado para evaluar, entre otros, riesgos de fracturas o estado de osteoporosis. La técnica de tomografía computada utiliza imágenes bidimensionales de rayos X y métodos de reconstrucción tomográfica implementados en algoritmos computacionales para obtener información de la estructura interna de un objeto, de forma no destructiva. Equipamientos especialmente desarrollados logran obtener imágenes con resolución sub-milimétrica, dando lugar a la técnica conocida como micro-tomografía. La posibilidad de estudiar estructuras óseas con este grado de resolución y obtener imágenes morfológicas tridimensionales con información de la densidad electrónica, presenta una importante opción para estudios específicos sobre, entre otros, crecimiento de hueso y estudios de nuevos componentes que permiten acelerar el crecimiento de tejidos dañados. En el presente trabajo se analizan muestras óseas del cráneo de conejos donde se han dañado determinadas zonas y se han injertado diferentes sustancias tendientes a evaluar respuestas de reparación de tejido óseo. El análisis se realiza a los fines de estudiar la performance de la técnica de micro-tomografía desarrollada en laboratorio con el objetivo de observar su potencialidad en este tipo de estudios y la capacidad de estos análisis en la caracterización de las propiedades físicas de este tipo de muestras.publishedVersionFil: Pérez, P. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación; Argentina.Fil: Pérez, P. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Instituto de Física Enrique Gaviola; Argentina.Fil: Malano, F. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación; Argentina.Fil: Malano, F. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Instituto de Física Enrique Gaviola; Argentina.Fil: Fernández Bodereau, E. Universidad Nacional de Córdoba, Facultad de Odontología; Argentina.Fil: Dedossi, G. Universidad Nacional de Córdoba, Facultad de Odontología; Argentina.Fil: Figueroa, R. Universidad de La Frontera. Temuco; Chile.Fil: Figueroa, R. Centro de Física e Ingeniería en Medicina. Universidad de La Frontera. Temuco; Chile.Fil: Santibañez, M. Universidad de La Frontera. Temuco; Chile.Fil: Santibañez, M. Centro de Física e Ingeniería en Medicina. Universidad de La Frontera. Temuco; Chile.Fil: Vedelago, J. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación; Argentina.Fil: Vedelago, J. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Instituto de Física Enrique Gaviola; Argentina.Fil: Vedelago, J. Universidad de La Frontera. Temuco; Chile.Fil: Vedelago, J. Centro de Física e Ingeniería en Medicina. Universidad de La Frontera. Temuco; Chile.Fil: Valente, M. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación; Argentina.Fil: Valente, M. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Instituto de Física Enrique Gaviola; Argentina.Fil: Valente, M. Universidad de La Frontera. Temuco; Chile.Fil: Valente, M. Centro de Física e Ingeniería en Medicina. Universidad de La Frontera. Temuco; Chile

    Raman spectroscopy as a tool to evaluate oxygen effects on the response of polymer gel dosimetry

    No full text
    Se seleccionó la licencia Creative Commons para este envío. El documento trae lo siguiente: CC BY-NC-ND. (En caso de duda consultar a Meilyn Garro).Currently, advanced dosimeters like polymer gels are capable of obtaining reliable and accurate 3D dose distributions from correlations with the different polymerization degrees induced by incident radiation. Samples of polymer gel dosimeters are commonly read out using magnetic resonance imaging or optical methods like visible light transmission or laser computed tomography. Alternatively, this work proposes and evaluates the implementation of Raman spectroscopy to provide direct information on the effect of oxygen permeating through the walls of phantoms on the polymerization initiated by irradiation in three types of polymer gel dosimeters, namely NIPAM, ITABIS and PAGAT. The aim of the present study is to provide better and complete interpretations using three different containers, adequate for integral, 2D and 3D dose mapping. Moreover, Raman spectroscopy has been used to analyze the well-known effect of oxygen inhibition on the different polymer gel dosimeters remarking the importance of avoiding air exposition during sample storage and readout. Dose-response curves for different polymer gels were obtained in terms of measurements with a calibrated ionization chamber. Additionally, dedicated Monte Carlo simulations were performed aimed at characterizing dose for different X-ray irradiation setups, providing also suitable information to evaluate oxygen diffusion through the sample wall. The obtained results were contrasted with optical transmission readout as well as Monte Carlo simulations attaining very good agreements for all dosimeter types. © 2019 Elsevier LtdActualmente, los dosímetros avanzados como los geles poliméricos son capaces de obtener distribuciones de dosis 3D fiables y precisas a partir de correlaciones con los diferentes grados de polimerización inducidos por la radiación incidente. Las muestras de dosímetros de gel de polímero se leen comúnmente utilizando imágenes por resonancia magnética o métodos ópticos como la transmisión de luz visible o la tomografía computarizada con láser. Alternativamente, este trabajo propone y evalúa la implementación de la espectroscopía Raman para proporcionar información directa sobre el efecto del oxígeno que penetra a través de las paredes de los maniquíes sobre la polimerización iniciada por irradiación en tres tipos de dosímetros de gel de polímero, a saber, NIPAM, ITABIS y PAGAT. El objetivo del presente estudio es proporcionar interpretaciones mejores y completas utilizando tres contenedores diferentes, adecuados para mapeo de dosis integral, 2D y 3D. Además, se ha utilizado la espectroscopia Raman para analizar el conocido efecto de la inhibición del oxígeno en los diferentes dosímetros de gel polimérico, destacando la importancia de evitar la exposición al aire durante el almacenamiento y la lectura de la muestra. Se obtuvieron curvas de dosis-respuesta para diferentes geles de polímero en términos de mediciones con una cámara de ionización calibrada. Además, se realizaron simulaciones específicas de Monte Carlo destinadas a caracterizar la dosis para diferentes configuraciones de irradiación de rayos X, proporcionando también información adecuada para evaluar la difusión de oxígeno a través de la pared de la muestra. Los resultados obtenidos se contrastaron con lectura de transmisión óptica y simulaciones de Monte Carlo logrando muy buenas concordancias para todos los tipos de dosímetros. © 2019 Elsevier LtdLaboratorio de Investigación e Instrumentación en Física Aplicada a la Medicina e Imágenes por Rayos X (LIIFAMIRx)Universidad Nacional de Córdoba, M. Allende s/n, Córdoba, ArgentinaDepartamento de Química Orgánica, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, CONICET, CórdobaInstituto de Física Enrique Gaviola (IFEG) - CONICET, M. Allende s/n, Córdoba, ArgentinaUniversidad Nacional, Costa RicaDepartamento de Físic

    Getting high to cope with COVID-19: Modelling the associations between cannabis demand, coping motives, and cannabis use and problems

    No full text
    During the COVID-19 pandemic, people may use substances like cannabis for enhancement or coping purposes. Behavioral economic demand for a substance is a key determinant of its use and misuse and can be measured via hypothetical purchase tasks. Previous research suggests that motivations to use a substance play a mediational role between elevated substance demand and problems, but comparable mechanistic research has yet to be done in the COVID-19 context and on the effects of cannabis demand on cannabis use patterns. Participants (n = 137) were recruited via the online crowdsourcing platform Prolific. Participants completed measures of cannabis use and problems, motivations for cannabis use, and the Marijuana Purchase Task. Two indices of demand, Persistence (i.e., sensitivity to increasing cost of cannabis) and Amplitude (i.e., consumption of cannabis at unrestricted cost), were related to increased cannabis problems via the use motive of coping during the COVID-19 pandemic. This model did not support the mediational role of enhancement motives. Those with increased cannabis demand who tend to use cannabis to cope are at increased risk of experiencing negative cannabis-related consequences during the COVID-19 pandemic

    Opinion: Integration of diagnostic and management perspectives for placenta accreta

    No full text
    The 2007 New South Wales/Queensland Royal Australian and New Zealand College of Obstetricians and Gynaecologists Annual Scientific Meeting convened a panel to discuss multidisciplinary perspectives on the management of placenta accreta, percreta or increta. While it was anticipated that this panel would stimulate discussion, the cohesion between the approaches was underestimated. This document represents an integration of the perspectives of the invited speakers at this presentation, with backgrounds in maternal-fetal medicine, gynaecological oncology, radiology and general obstetrics and gynaecology