85 research outputs found

    Real-life experience with non-vitamin K antagonist oral anticoagulants versus warfarin in patients undergoing elective cardioversion of atrial fibrillation

    Get PDF
    Background Nonvitamin K antagonist oral anticoagulants (NOACs) are increasingly used in patients with atrial fibrillation (AF) undergoing elective cardioversion (ECV). The aim was to investigate the use of NOACs and warfarin in ECV in a real-life setting and to assess how the chosen regimen affected the delay to ECV and rate of complications. Methods Consecutive AF patients undergoing ECVs in the city hospitals of Helsinki between January 2015 and December 2016 were studied. Data on patient characteristics, delays to cardioversion, anticoagulation treatment, acute ( Results Nine hundred patients (59.2% men; mean age, 68.0 +/- 10.0) underwent 992 ECVs, of which 596 (60.0%) were performed using NOACs and 396 (40.0%) using warfarin. The mean CHA(2)DS(2)-VASc score was 2.5 (+/- 1.6). In patients without previous anticoagulation treatment, NOACs were associated with a shorter mean time to cardioversion than warfarin (51 versus. 68 days, respectively; p <.001). Six thromboembolic events (0.6%) occurred: 4 (0.7%) in NOAC-treated patients and 2 (0.5%) in warfarin-treated patients. Clinically relevant bleeding events occurred in seven patients (1.8%) receiving warfarin and three patients (0.5%) receiving NOACs. Anticoagulation treatment was altered for 99 patients (11.0%) during the study period, with the majority (88.2%) of changes from warfarin to NOACs. Conclusions In this real-life study, the rates of thromboembolic and bleeding complications were low in AF patients undergoing ECV. Patients receiving NOAC therapy had a shorter time to cardioversion and continued their anticoagulation therapy more often than patients on warfarin.Peer reviewe

    Self-detection of atrial fibrillation in an aged population: three-year follow-up of the LietoAF intervention study

    Get PDF
    BackgroundAtrial fibrillation (AF) is often asymptomatic and undiagnosed until an ischaemic stroke occurs. An irregular pulse is a key manifestation of AF. We assessed whether pulse self-palpation is feasible in screening of AF.MethodsAltogether 205 residents of Lieto municipality aged ≥75 years were randomized in 2012 to receive brief education on pulse palpation focusing on evaluating rhythm regularity. Self-detected pulse irregularity and new AF diagnoses were recorded, and the subjects’ quality of life and use of health care services were assessed during a three-year follow-up.ResultsThe subjects’ median age was 78.2 [3.8] years, and 89 (43.4%) were men. Overall, 139 (68%) subjects had initial good motivation/capability for regular palpation. At four months, 112 (80.6%) subjects with good and 26 (39.4%) with inadequate motivation/capability palpated their pulse daily. At 12 months, 120 (58.5%) and at 36 months, 69 (33.7%) subjects palpated their pulse at least weekly. During the intervention, 67 (32.7%) subjects reported pulse irregularity. New AF was found in 10 (4.9%) subjects, 7 (70%) of whom had reported pulse irregularity. Pulse irregularity independently predicted new AF, but only one (0.5%) subject with new AF sought undelayed medical attention due to pulse irregularity. Quality of life and number of outpatient clinic visits remained unchanged during follow-up.ConclusionPulse palpation can be learned also by the elderly, but it is challenging to form a continuing habit. The low persistence of pulse self-palpation limits its value in the screening of AF, and strategies to promote persistence and research on alternative screening methods are needed.         </p

    Advanced interatrial block predicts ineffective cardioversion of atrial fibrillation: a FinCV2 cohort study

    Get PDF
    Aims: Rhythm control using electrical cardioversion (CV) is a common treatment strategy for patients with symptomatic atrial fibrillation (AF). To guide clinical decision making, we sought to assess if electrocardiographic interatrial blocks could predict CV failure or AF recurrence as the phenomenon is strongly associated with atrial arrhythmias.Methods: This study included 715 patients who underwent a CV for persistent AF lasting >48 h. P-wave duration and morphology were analyzed in post-procedure or the most recent sinus rhythm electrocardiograms and compared with rates of CV failure and AF recurrence within 30 days after CV as well as their combination (ineffective CV).Results: CV was unsuccessful in 63 out of 715 patients (8.8%) and AF recurred in 209 out of 652 (29.2%) patients within 30 days after CV. Overall, 272 (38.0%) CVs turned out ineffective. Advanced interatrial block (AIAB) defined as P-wave duration >= 120 ms and biphasic morphology in inferior leads (II, III and aVF) was diagnosed in 72 (10.1%) cases. AIAB was an independent predictor for CV failure (OR 4.51, 95%CI 1.76-11.56, p = .002), AF recurrence (OR 2.93, 95%CI 1.43-5.99, p = .003) and ineffective CV (OR 3.87, 95%CI 2.04-7.36, p Conclusion: AIAB predicted CV failure, AF recurrence as well as their composite. This study presents an easy electrocardiographic tool for the identification of patients with persistent AF who might not benefit from an elective CV in the future. KEY MESSAGESInteratrial blocks are very common in patients with atrial fibrillation.Advanced interatrial block predicts ineffective cardioversion.</div

    Mechanocardiography in the Detection of Acute ST Elevation Myocardial Infarction: The MECHANO-STEMI Study

    Get PDF
    Novel means to minimize treatment delays in patients with ST elevation myocardial infarction (STEMI) are needed. Using an accelerometer and gyroscope on the chest yield mechanocardiographic (MCG) data. We investigated whether STEMI causes changes in MCG signals which could help to detect STEMI. The study group consisted of 41 STEMI patients and 49 control patients referred for elective coronary angiography and having normal left ventricular function and no valvular heart disease or arrhythmia. MCG signals were recorded on the upper sternum in supine position upon arrival to the catheterization laboratory. In this study, we used a dedicated wearable sensor equipped with 3-axis accelerometer, 3-axis gyroscope and 1-lead ECG in order to facilitate the detection of STEMI in a clinically meaningful way. A supervised machine learning approach was used. Stability of beat morphology, signal strength, maximum amplitude and its timing were calculated in six axes from each window with varying band-pass filters in 2–90 Hz range. In total, 613 features were investigated. Using logistic regression classifier and leave-one-person-out cross validation we obtained a sensitivity of 73.9%, specificity of 85.7% and AUC of 0.857 (SD = 0.005) using 150 best features. As a result, mechanical signals recorded on the upper chest wall with the accelerometers and gyroscopes differ significantly between STEMI patients and stable patients with normal left ventricular function. Future research will show whether MCG can be used for the early screening of STEMI.</p

    Red blood cell transfusion induces abnormal HIF-1 alpha response to cytokine storm after adult cardiac surgery

    Get PDF
    Patients undergoing cardiac surgery develop a marked postoperative systemic inflammatory response. Blood transfusion may contribute to disruption of homeostasis in these patients. We sought to evaluate the impact of blood transfusion on serum interleukin-6 (IL-6), hypoxia induced factor-1 alpha (HIF-1 alpha) levels as well as adverse outcomes in patients undergoing adult cardiac surgery. We prospectively enrolled 282 patients undergoing adult cardiac surgery. Serum IL-6 and HIF-1 alpha levels were measured preoperatively and on the first postoperative day. Packed red blood cells were transfused in 26.3% of patients (mean 2.93 +/- 3.05 units) by the time of postoperative sampling. Postoperative IL-6 levels increased over 30-fold and were similar in both groups (p = 0.115), whilst HIF-1 alpha levels (0.377 pg/mL vs. 0.784 pg/mL, p = 0.002) decreased significantly in patients who received red blood cell transfusion. Moreover, greater decrease in HIF-1 alpha levels predicted worse in-hospital and 3mo adverse outcome. Red blood cell transfusion was associated with higher risk of major adverse outcomes (stroke, pneumonia, all-cause mortality) during the index hospitalization. Red blood cell transfusion induces blunting of postoperative HIF-1 alpha response and is associated with higher risk of adverse thrombotic and pulmonary adverse events after cardiac surgery.Peer reviewe

    Multiclass Classifier based Cardiovascular Condition Detection Using Smartphone Mechanocardiography

    Get PDF
    Cardiac translational and rotational vibrations induced by left ventricular motions are measurable using joint seismocardiography (SCG) and gyrocardiography (GCG) techniques. Multi-dimensional non-invasive monitoring of the heart reveals relative information of cardiac wall motion. A single inertial measurement unit (IMU) allows capturing cardiac vibrations in sufficient details and enables us to perform patient screening for various heart conditions. We envision smartphone mechanocardiography (MCG) for the use of e-health or telemonitoring, which uses a multi-class classifier to detect various types of cardiovascular diseases (CVD) using only smartphone’s built-in internal sensors data. Such smartphone App/solution could be used by either a healthcare professional and/or the patient him/herself to take recordings from their heart. We suggest that smartphone could be used to separate heart conditions such as normal sinus rhythm (SR), atrial fibrillation (AFib), coronary artery disease (CAD), and possibly ST-segment elevated myocardial infarction (STEMI) in multiclass settings. An application could run the disease screening and immediately inform the user about the results. Widespread availability of IMUs within smartphones could enable the screening of patients globally in the future, however, we also discuss the possible challenges raised by the utilization of such self-monitoring systems.</p

    Assessing an Electronic Health Record research platform for identification of clinical trial participants

    Get PDF
    Electronic health records (EHR) are a potential resource for identification of clinical trial participants. We evaluated how accurately a commercially available EHR Research Platform, InSite, is able to identify potential trial participants from the EHR system of a large tertiary care hospital. Patient counts were compared with results obtained in a conventional manual search performed for a reference study that investigated the associations of atrial fibrillation (AF) and cerebrovascular incidents. The Clinical Data Warehouse (CDW) of Turku University Hospital was used to verify the capabilities of the EHR Research Platform.The EHR query resulted in a larger patient count than the manual query (EHR Research Platform 5859 patients, manual selection 2166 patients). This was due to the different search logic and some exclusion criteria that were not addressable in structured digital format. The EHR Research Platform (5859 patients) and the CDW search (5840 patients) employed the same search logic. The temporal relationship between the two diagnoses could be identified when they were available in structured format and the time difference was longer than a single hospital visit.Searching for patients with the EHR Research Platform can help to identify potential trial participants from a hospital's EHR system by limiting the number of records to be manually reviewed. EHR query tools can best be utilized in trials where the selection criteria are expressed in structured digital format.</p

    Mechanocardiography-Based Measurement System Indicating Changes in Heart Failure Patients during Hospital Admission and Discharge

    Get PDF
    Heart failure (HF) is a disease related to impaired performance of the heart and is a significant cause of mortality and treatment costs in the world. During its progression, HF causes worsening (decompensation) periods which generally require hospital care. In order to reduce the suffering of the patients and the treatment cost, avoiding unnecessary hospital visits is essential, as hospitalization can be prevented by medication. We have developed a data-collection device that includes a high-quality 3-axis accelerometer and 3-axis gyroscope and a single-lead ECG. This allows gathering ECG synchronized data utilizing seismo- and gyrocardiography (SCG, GCG, jointly mechanocardiography, MCG) and comparing the signals of HF patients in acute decompensation state (hospital admission) and compensated condition (hospital discharge). In the MECHANO-HF study, we gathered data from 20 patients, who each had admission and discharge measurements. In order to avoid overfitting, we used only features developed beforehand and selected features that were not outliers. As a result, we found three important signs indicating the worsening of the disease: an increase in signal RMS (root-mean-square) strength (across SCG and GCG), an increase in the strength of the third heart sound (S3), and a decrease in signal stability around the first heart sound (S1). The best individual feature (S3) alone was able to separate the recordings, giving 85.0% accuracy and 90.9% accuracy regarding all signals and signals with sinus rhythm only, respectively. These observations pave the way to implement solutions for patient self-screening of the HF using serial measurements. </p

    A Respiratory Motion Estimation Method Based on Inertial Measurement Units for Gated Positron Emission Tomography

    Get PDF
    We present a novel method for estimating respiratory motion using inertial measurement units (IMUs) based on microelectromechanical systems (MEMS) technology. As an application of the method we consider the amplitude gating of positron emission tomography (PET) imaging, and compare the method against a clinically used respiration motion estimation technique. The presented method can be used to detect respiratory cycles and estimate their lengths with state-of-the-art accuracy when compared to other IMU-based methods, and is the first based on commercial MEMS devices, which can estimate quantitatively both the magnitude and the phase of respiratory motion from the abdomen and chest regions. For the considered test group consisting of eight subjects with acute myocardial infarction, our method achieved the absolute breathing rate error per minute of 0.44 +/- 0.23 1/min, and the absolute amplitude error of 0.24 +/- 0.09 cm, when compared to the clinically used respiratory motion estimation technique. The presented method could be used to simplify the logistics related to respiratory motion estimation in PET imaging studies, and also to enable multi-position motion measurements for advanced organ motion estimation.</p

    Frequency of cardioversions as an additional risk factor for stroke in atrial fibrillation - the FinCV-4 study

    Get PDF
    BackgroundPatients with atrial fibrillation (AF) are selected for oral anticoagulation based on individual patient characteristics. There is little information on how clinical AF burden associates with the risk of ischaemic stroke or systemic embolism (SSE). The aim of this study was to explore the association of the frequency of cardioversions (CV) as a measure of clinical AF burden on the long-term SSE risk, with a focus on patients at intermediate stroke risk based on CHA(2)DS(2)-VASc score. For these patients, additional SSE risk stratification by assessing CV frequency may aid in the decision on whether to initiate oral anticoagulation.MethodsThis retrospective analysis of FinCV Study from years 2003-2010 included 2074 patients who were not using any oral anticoagulation (long term or temporary) after CVs and undergoing a total of 6534 CVs for AF from emergency departments of three hospitals. Two study groups were formed: high CV frequency (mean interval between CVs 12 months).ResultsA total of 107 SSEs occurred during a mean follow-up of 5.4 years. The event rates per 100 patient-years were 1.82 and 0.67 in high versus low CV frequency groups, respectively. After adjustment for CHA(2)DS(2)-VASc score, CV frequency independently predicted SSE (HR, 2.87 [95% CI, 1.47 to 5.64]; p = .002) at 3 years. Competing risk analysis also identified CV frequency (sHR, 2.70 [95% CI, 1.38-5.31]; p = .004) as an independent predictor for SSE. In patients with CHA(2)DS(2)-VASc score 1 and low CV frequency, the SSE risk was only 0.08 per 100 patient-years.ConclusionsFrequency of CVs for symptomatic AF episodes provides additional information on stroke risk in AF patients with CHA(2)DS(2)-VASc score 1. Key messages This retrospective study offers a unique opportunity to observe the natural course of AF patients with infrequent episodes of clinical arrhythmia when they were not using OAC (before introduction of CHA(2)DS(2)-VASc score). Stroke or systemic embolism rate was very low (0.08 per 100 patient-years) in patients with one CHA(2)DS(2)-VASc point who visited the emergency room for cardioversion less than once a year. Frequency of cardioversions can be used for additional risk stratification in patients at intermediate risk of stroke based on CHA(2)DS(2)-VASc score.</p
    • …
    corecore