58 research outputs found

    Assessment of Fluid Cavitation Threshold Using a Polymeric Split Hopkinson Bar-Confinement Chamber Apparatus

    Get PDF
    The authors would like to acknowledge the Natural Sciences and Engineering Research Council of Canada for financial support, and Compute Canada and Sharcnet for providing the necessary computing resources.Mild Traumatic Brain Injury (mTBI) has been associated with blast exposure resulting from the use of improvised explosive devices (IEDs) in recent and past military conflicts. Experimental and numerical models of head blast exposure have demonstrated the potential for high negative pressures occurring within the head at the contre-coup location relative to the blast exposure, and it has been hypothesized that this negative pressure could result in cavitation of Cerebrospinal Fluid (CSF) surrounding the brain, leading to brain tissue damage. The cavitation threshold of CSF, the effect of temperature, and the effect of impurities or dissolved gases are presently unknown. In this study, a novel Polymeric Split Hopkinson Pressure Bar and confinement chamber apparatus were used to generate loading in distilled water similar to the conditions in the vicinity of the CSF during blast exposure. Cavitation was identified using high-speed imaging of the event, and a validated numerical model of the apparatus was applied to determine the pressure in the fluid during the exposure. Increasing the water temperature resulted in a decrease in the 50% probability of cavitation from 21 °C (−3320 kPa ± 3%) to 37 °C (−3195 kPa ± 5%) in agreement with the theoretical values, but was not statistically significant. Importantly, the effect of water treatment had a significant effect on the cavitation pressure for water with wetting agent (−3320 kPa ± 3%), degassed water (−1369 kPa ± 16%) and untreated distilled water (−528 kPa ± 25%). Thus, reducing dissolved gases through degassing or the use of a wetting agent significantly increases the cavitation pressure and reduces the variability of the cavitation pressure threshold

    Probing polydopamine adhesion to protein and polymer films: microscopic and spectroscopic evaluation

    Get PDF
    Polydopamine has been found to be a biocompatible polymer capable of supporting cell growth and attachment, and to have antibacterial and antifouling properties. Together with its ease of manufacture and application, it ought to make an ideal biomaterial and function well as a coating for implants. In this paper, atomic force microscopy was used to measure the adhesive forces between polymer-, protein- or polydopamine-coated surfaces and a silicon nitride or polydopamine-functionalised probes. Surfaces were further characterised by contact angle goniometry, and solutions by circular dichroism. Polydopamine was further characterised with infrared spectroscopy and Raman spectroscopy. It was found that polydopamine functionalisation of the atomic force microscope probe significantly reduced adhesion to all tested surfaces. For example, adhesion to mica fell from 0.27 ± 0.7 nN nm-1 to 0.05 ± 0.01 nN nm-1. The results suggest that polydopamine coatings are suitable to be used for a variety of biomedical applications

    Two risk metrics for CO 2

    No full text

    Thermodynamics of Real Gases

    No full text
    • 

    corecore